a.
Select
the
Recovery
Guru
toolbar
button
in
the
Subsystem
Management
Window
to
run
the
Recovery
Guru.
b.
Complete
the
recovery
procedure.
If
the
Recovery
Guru
directs
you
to
replace
a
failed
component,
use
the
individual
LEDs
on
the
storage
subsystem
to
locate
the
specific
failed
component.
c.
When
the
procedure
is
completed,
select
Recheck
in
the
Recovery
Guru.
This
will
rerun
the
Recovery
Guru
to
ensure
that
the
problem
has
been
fixed.
d.
If
the
problem
has
not
been
fixed
contact
your
IBM
service
representative.
a
storage
subsystem
profile
and
save
the
storage
subsystem
support
data.
The
profile
and
support
data
will
be
helpful
when
troubleshooting
storage
subsystem
problems.
(For
information
about
printing
a
storage
subsystem
profile
and
saving
the
support
data,
refer
to
the
Subsystem
Management
Window
online
help.)
Resetting
the
controller
circuit
breakers
Each
storage
subsystem
controller
has
two
circuit
breakers
that
provide
over-current
protection
to
the
power
supply
in
a
power
supply-fan.
The
circuit
breakers
are
mounted
inside
the
controller,
in
line
with
the
internal
power
cable.
One
circuit
breaker
provides
protection
for
AC
input,
and
the
second
circuit
breaker
provides
protection
for
DC
input.
Note:
DC
power
input
is
not
currently
supported
for
the
DS4800.
Contact
your
IBM
service
representative
or
reseller
for
information
about
possible
future
support
for
DC
power
input.
The
internal
power
cable
runs
from
the
AC
connector
on
a
controller
to
the
power
supply
in
a
power
supply-fan.
Power
to
the
right
power
supply-fan
(as
viewed
from
the
front
of
the
storage
subsystem)
is
routed
through
the
top
controller
(controller
A);
power
to
the
left
power
supply-fan
is
routed
through
the
bottom
controller
(controller
B).
If
a
circuit
breaker
has
tripped,
the
condition
might
appear
as
if
a
power
supply-fan
has
failed.
The
power
supply
is
no
longer
providing
power
to
the
storage
subsystem.
A
tripped
circuit
breaker
is
indicated
when
all
of
the
following
conditions
are
present:
v
The
Overall
DS4800
Configuration
Needs
Attention
on
the
storage
subsystem
front
bezel
is
turned
on
v
The
controller
Needs
Attention
LEDs
are
not
turned
on
v
The
power
supply-fan
Needs
Attention
LEDs
are
not
turned
on
v
The
Service
Action
Allowed
LED
is
turned
on
for
the
power
supply-fan
connected
to
the
controller
with
the
open
circuit
breaker
v
The
DS4000
Storage
Manager
client
shows
the
power
supply-fan
unit
has
failed
Use
the
following
procedure
to
reset
the
circuit
breaker.
Tools
and
Equipment
v
Antistatic
protection
v
Nonconducting
stylus
124
IBM
System
Storage
DS4800
Storage
Subsystem:
Installation,
User’s,
and
Maintenance
Guide
Содержание TotalStorage DS4800
Страница 1: ...IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide GC26 7845 00...
Страница 2: ......
Страница 3: ...IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide GC26 7845 00...
Страница 18: ...xvi IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 22: ...xx IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 55: ...ds48020 Figure 12 DS4800 front rack mounting template Chapter 2 Installing the storage subsystem 33...
Страница 68: ...46 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 114: ...92 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 154: ...132 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 200: ...178 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 202: ...180 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 205: ...ds48021 Figure 102 DS4800 rear rack mounting template Appendix C Rack mounting templates 183...
Страница 206: ...184 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 226: ...204 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 233: ......
Страница 234: ...Part Number 23R1992 Printed in USA GC26 7845 00 1P P N 23R1992...