Attention:
Power
supplies
automatically
shut
down
when
air
temperature
inside
the
cabinet
reaches
70°
C
(158°
F)
or
above.
If
the
power
supplies
have
shut
down,
immediately
remove
all
cabinet
panels
to
help
cool
the
cabinet
air
temperature
and
prevent
damage
to
the
storage
subsystem.
Note:
If
both
power
supply-fan
units
have
shut
down,
start
with
step
below.
1.
If
applicable,
turn
off
the
alarm.
2.
Use
the
DS4000
Storage
Manager
client
software
to
a
storage
subsystem
profile.
3.
In
the
DS4000
Storage
Manager
client
Subsystem
Management
window,
select
Advanced
Troubleshooting
View
Event
Log
to
display
the
DS4800
critical
events.
Look
for
one
of
the
following
critical
event
entries:
v
Event
281B
-
Nominal
temperature
exceeded
v
Event
281C-
Maximum
temperature
exceeded
4.
Try
alleviating
the
overheating
problem
by:
v
Removing
all
panels
from
the
cabinet
v
Cooling
the
area
using
external
fans
v
Shutting
down
the
power
to
the
storage
subsystem
or
storage
expansion
enclosures
(Follow
the
power-down
procedure
described
in
5.
Stop
all
I/O
activity
to
the
storage
subsystem
and
to
all
attached
storage
expansion
enclosures.
6.
Wait
until
the
ambient
air
temperature
around
the
storage
subsystem
cools.
The
storage
subsystem
is
capable
of
power-up
recovery
without
operator
intervention
after
the
temperature
inside
the
power
supply-fan
cools
to
below
70°
C
(158°
F).
After
the
air
has
cooled,
the
power
supplies
should
turn
on
automatically.
If
the
power
supplies
restart
automatically,
the
controllers
reset
and
return
to
normal
operation.
7.
Did
the
power
supplies
restart
automatically?
v
Yes
–
Go
to
step
v
No
–
Go
to
step
8.
Turn
off
the
power
switch
on
each
controller
in
the
storage
subsystem
and
then
power
off
all
connected
storage
expansion
enclosures.
Wait
1
minute
and
then
turn
on
power
to
all
connected
storage
expansion
enclosures
and
then
to
the
storage
subsystem.
If
the
power
supplies
go
into
operation,
go
to
step
If
not,
call
your
IBM
service
representative.
9.
Check
the
status
LEDs
on
the
front
and
back
of
the
storage
subsystem.
For
information
about
storage
subsystem
LEDs,
see
10.
Are
the
LEDs
on
the
storage
subsystem
indicating
normal
status?
v
Yes
–
Go
to
step
v
No
–
Go
to
step
11.
Use
the
DS4000
Storage
Manager
client
software
to
check
the
status
of
all
storage
subsystems
in
the
configuration.
Is
the
status
Optimal
for
each
storage
subsystem?
v
Yes
–
End
of
procedure.
Resume
normal
operation.
v
No
–
Go
to
step
12.
Diagnose
and
correct
the
fault
by
completing
the
following
steps.
Chapter
4.
Operating
the
storage
subsystem
123
Содержание TotalStorage DS4800
Страница 1: ...IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide GC26 7845 00...
Страница 2: ......
Страница 3: ...IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide GC26 7845 00...
Страница 18: ...xvi IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 22: ...xx IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 55: ...ds48020 Figure 12 DS4800 front rack mounting template Chapter 2 Installing the storage subsystem 33...
Страница 68: ...46 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 114: ...92 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 154: ...132 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 200: ...178 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 202: ...180 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 205: ...ds48021 Figure 102 DS4800 rear rack mounting template Appendix C Rack mounting templates 183...
Страница 206: ...184 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 226: ...204 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 233: ......
Страница 234: ...Part Number 23R1992 Printed in USA GC26 7845 00 1P P N 23R1992...