POST
Error
Code
FRU/Action
101XX
Not
listed
above
1.
Modem
Adapter/A
2.
Data/Fax
Modem
3.
System
Board
4.
Riser
card
10450,
10451,
10490,
10491,
10492,
10499
Read/write
error
1.
Run
Enhanced
Diagnostics
2.
Hard
Disk
Drive
3.
System
Board
4.
Riser
card
10452
Seek
test
error
Run
Enhanced
Diagnostics
10453
Wrong
drive
type?
Information
only
10454
Sector
buffer
test
error
Run
Enhanced
Diagnostics
10455,
10456
Controller
error
Run
Enhanced
Diagnostics
10459
Drive
diagnostic
command
error
Information
only
10461
Drive
format
error
Run
Enhanced
Diagnostics
10462
Controller
seek
error
Run
Enhanced
Diagnostics
10464
Hard
Drive
read
error
Run
Enhanced
Diagnostics
10467
Drive
non-fatal
seek
error
Run
Enhanced
Diagnostics
10468
Drive
fatal
seek
error
Run
Enhanced
Diagnostics
10469
Drive
soft
error
count
exceeded
Run
Enhanced
Diagnostics
10470,
10471,
10472
Controller
wrap
error
Run
Enhanced
Diagnostics
10473
Corrupt
data.
Low
level
format
might
be
required
Information
only
10480
1.
Hard
Disk
Drive
(ESDI)
2.
Drive
Cable
3.
System
Board
10481
ESDI
drive
D
seek
error
Run
Enhanced
Diagnostics
10482
Drive
select
acknowledgement
bad
Run
Enhanced
Diagnostics
106X1
1.
Check
Configuration
2.
Ethernet
Adapter
Chapter
7.
Symptom-to-FRU
Index
101
Содержание THINKCENTER 8128
Страница 2: ......
Страница 16: ...10 Hardware Maintenance Manual...
Страница 20: ...14 Hardware Maintenance Manual...
Страница 30: ...1 USB connector 2 USB connector 24 Hardware Maintenance Manual...
Страница 32: ...1 USB connector 2 USB connector 26 Hardware Maintenance Manual...
Страница 39: ...Chapter 6 Replacing FRUs 33...
Страница 68: ...Types 8185 8186 8192 8413 and 8430 Types 8128 8187 8188 8193 8414 and 8431 62 Hardware Maintenance Manual...
Страница 74: ...68 Hardware Maintenance Manual...
Страница 124: ...118 Hardware Maintenance Manual...
Страница 263: ...Chapter 10 Related service information 257...
Страница 264: ...258 Hardware Maintenance Manual...
Страница 265: ...Chapter 10 Related service information 259...
Страница 266: ...260 Hardware Maintenance Manual...
Страница 267: ...Chapter 10 Related service information 261...
Страница 268: ...262 Hardware Maintenance Manual...
Страница 269: ...Chapter 10 Related service information 263...
Страница 270: ...264 Hardware Maintenance Manual...
Страница 276: ...1 2 ACHTUNG Keine Gegenst nde die mehr als 82 kg wiegen auf Rack Einheiten ablegen 270 Hardware Maintenance Manual...
Страница 280: ...274 Hardware Maintenance Manual...
Страница 281: ...Chapter 10 Related service information 275...
Страница 282: ...276 Hardware Maintenance Manual...
Страница 289: ......
Страница 290: ...Part Number 74P2661 Printed in USA 1P P N 74P2661...