Error
code
Description
Action
187
VPD
serial
number
not
set.
1.
Run
the
Configuration/Setup
Utility
program,
set
the
serial
number,
and
save
the
configuration.
2.
(Trained
service
technician
only)
Replace
the
system
board.
189
An
attempt
was
made
to
access
the
server
with
an
incorrect
password.
Restart
the
server
and
enter
the
administrator
password;
then,
run
the
Configuration/Setup
Utility
program
and
change
the
power-on
password.
289
A
DIMM
has
been
disabled
by
the
user
or
by
the
system.
1.
If
the
DIMM
was
disabled
by
the
user,
run
the
Configuration/Setup
Utility
program
and
enable
the
DIMM.
2.
Make
sure
that
the
DIMM
is
installed
correctly
(see
“Installing
a
memory
module”
on
page
114).
3.
Reseat
the
DIMM.
4.
Replace
the
DIMM.
301
Keyboard
or
keyboard
controller
error.
1.
Reseat
the
keyboard
cable
in
the
USB
connector.
2.
Move
the
keyboard
cable
to
a
different
USB
connector.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Keyboard
b.
(Only
if
the
problem
occurred
with
a
front
USB
connector)
Internal
USB
cable.
c.
(Trained
service
technician
only)
System
board
303
Keyboard
controller
error.
1.
Reseat
the
keyboard
cable
in
the
USB
connector.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Keyboard
b.
(Trained
service
technician
only)
System
board
1600
Service
processor
not
functioning.
1.
Reseat
the
optional
Remote
Supervisor
Adapter
II
SlimLine.
2.
Replace
the
optional
Remote
Supervisor
Adapter
II
SlimLine.
30
IBM
System
x3650
Type
7979
and
1914:
Problem
Determination
and
Service
Guide
Содержание System x3650 Type 7979
Страница 1: ...IBM System x3650 Type 7979 and 1914 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3650 Type 7979 and 1914 Problem Determination and Service Guide...
Страница 8: ...vi IBM System x3650 Type 7979 and 1914 Problem Determination and Service Guide...
Страница 18: ...xvi IBM System x3650 Type 7979 and 1914 Problem Determination and Service Guide...
Страница 104: ...86 IBM System x3650 Type 7979 and 1914 Problem Determination and Service Guide...
Страница 180: ...162 IBM System x3650 Type 7979 and 1914 Problem Determination and Service Guide...
Страница 193: ......
Страница 194: ...Part Number 31R1705 Printed in USA 1P P N 31R1705...