Installing
the
2.5-inch-drive
backplane
To
install
the
replacement
2.5-inch-drive
hard
disk
drive
backplane,
complete
the
following
steps.
2.5" hard disk
drive cage assembly
1.
Align
the
replacement
backplane
cage
assembly
with
the
opening
in
the
front
of
the
server.
2.
Slide
the
backplane
cage
assembly
into
the
front
of
the
server
until
it
clicks
into
place.
Make
sure
the
release
latches
hold
the
backplane
securely
in
place.
3.
Connect
the
power
and
signal
cables
to
the
backplane.
4.
Replace
the
fan
bracket
assembly
(see
“Installing
the
fan-bracket
assembly”
on
page
95).
5.
Install
the
cover
(see
“Installing
the
cover”
on
page
91).
6.
Slide
the
server
into
the
rack.
7.
Insert
the
hard
disk
drives
into
the
bays.
8.
Connect
the
cables
and
power
cords.
9.
Turn
on
all
attached
devices
and
the
server.
Chapter
4.
Removing
and
replacing
server
components
133
Содержание System x3650 Type 7979
Страница 1: ...IBM System x3650 Type 7979 and 1914 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3650 Type 7979 and 1914 Problem Determination and Service Guide...
Страница 8: ...vi IBM System x3650 Type 7979 and 1914 Problem Determination and Service Guide...
Страница 18: ...xvi IBM System x3650 Type 7979 and 1914 Problem Determination and Service Guide...
Страница 104: ...86 IBM System x3650 Type 7979 and 1914 Problem Determination and Service Guide...
Страница 180: ...162 IBM System x3650 Type 7979 and 1914 Problem Determination and Service Guide...
Страница 193: ......
Страница 194: ...Part Number 31R1705 Printed in USA 1P P N 31R1705...