Table 2. Light path diagnostics panel LEDs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
LED
Description
Action
CPU
When only the CPU LED is lit, a
microprocessor has failed.
When both the CPU and CONFIG
LEDs are lit, the microprocessor
configuration is invalid.
1. If the CONFIG LED is not lit, a microprocessor failure
occurs, complete the following steps:
a. (Trained technician only) Make sure that the failing
microprocessor and its heat sink, which are indicated
by a lit LED on the system board, are installed
correctly. See “Installing a second microprocessor and
heat sink” on page 101 for information about
installation and requirements.
b. (Trained technician only) Replace the failing
microprocessor (see “Installing a second
microprocessor and heat sink” on page 101).
c. For more information, go to http://www.ibm.com/
systems/support/supportsite.wss/
docdisplay?brandind=5000008&lndocid=SERV-CALL.
2. If the CONFIG LED and the CPU LED are lit, the system
issues an invalid microprocessor configuration error.
Complete the following steps to correct the problem:
a. Check the microprocessors that were just installed to
make sure that they are compatible with each other
(see “Installing a second microprocessor and heat
sink” on page 101 for additional information about
microprocessor requirements).
b. (Trained technician only) Replace the incompatible
microprocessor.
c. Check the system-error logs for information about the
error. Replace any component that is identified in the
error log.
MEM
When only the MEM LED is lit, a
memory error has occurred.
When both the MEM and CONFIG
LEDs are lit, the memory
configuration is invalid.
Note:
Each time you install or remove a DIMM, you must
disconnect the server from the power source; then, wait 10
seconds before restarting the server.
1. If the CONFIG LED is not lit, the system might detect a
memory error. Complete the following steps to correct the
problem:
a. Update the server firmware to the latest level (see the
Problem Determination and Service Guide
for more
information).
b. Reseat or swap the DIMMs.
c. Check the system-event log in the Setup utility or IMM
error messages (see the
Problem Determination and
Service Guide
for more information).
d. Replace the failing DIMM (see “Installing a memory
module” on page 107).
2. If the MEM LED and the CONFIG LED are lit, check the
system-event log in the Setup utility or IMM error
messages (see the
Problem Determination and Service
Guide
for more information).
Chapter 1. The System x3650 M4 server
21
Содержание System x3650 M4 Type 7915
Страница 1: ...System x3650 M4 Type 7915 Installation and User s Guide...
Страница 2: ......
Страница 3: ...System x3650 M4 Type 7915 Installation and User s Guide...
Страница 8: ...vi System x3650 M4 Type 7915 Installation and User s Guide...
Страница 10: ...Bu r n kurmadan nce g venlik bilgilerini okuyun viii System x3650 M4 Type 7915 Installation and User s Guide...
Страница 17: ...CAUTION Hazardous moving parts are nearby Safety xv...
Страница 18: ...xvi System x3650 M4 Type 7915 Installation and User s Guide...
Страница 48: ...30 System x3650 M4 Type 7915 Installation and User s Guide...
Страница 106: ...Port 12 15 Port 8 11 Adapter SAS signal cables 88 System x3650 M4 Type 7915 Installation and User s Guide...
Страница 113: ...Port 20 23 Port 16 19 Adapter SAS signal cables Chapter 2 Installing optional devices 95...
Страница 158: ...140 System x3650 M4 Type 7915 Installation and User s Guide...
Страница 184: ...166 System x3650 M4 Type 7915 Installation and User s Guide...
Страница 190: ...172 System x3650 M4 Type 7915 Installation and User s Guide...
Страница 191: ......
Страница 192: ...Part Number 00V9884 Printed in USA 1P P N 00V9884...