v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
180-xxx-005
Failed
SCSI
backplane
LED
test.
1.
Reseat
the
following
components:
a.
SAS/SATA
hard
disk
drive
b.
SAS/SATA
hard
disk
drive
backplane
cable
c.
RAID
adapter
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
SAS/SATA
hard
disk
drive
backplane
b.
SAS/SATA
hard
disk
drive
backplane
cable
c.
RAID
adapter
d.
(Trained
service
technician
only)
System
board
180-xxx-006
Failed
memory
LED
test.
1.
Reseat
the
DIMM.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
DIMM
b.
(Trained
service
technician
only)
System
board
180-xxx-007
Failed
power
supply
fan
LED
test.
1.
Reseat
the
power
supply.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Power
supply
b.
(Trained
service
technician
only)
System
board
180-xxx-008
Failed
I/O
board
LED
test.
(Trained
service
technician
only)
Replace
the
system
board.
180-xxx-009
Failed
Active
™
PCI
LED
test.
(Trained
service
technician
only)
Replace
the
system
board.
201-198-000
Memory
Test
Aborted:
Could
not
run
the
test;
suspect
system
board
error.
1.
Restart
the
server.
2.
Run
the
diagnostic
test
again.
3.
Reinstall
the
diagnostic
programs
(see
4.
(Trained
service
technician
only)
Replace
the
system
board.
201-198-00n
Memory
Test
Aborted:
Could
not
run
the
test.
Note:
n
=
1-9
(programming
error).
1.
Restart
the
server.
2.
Run
the
diagnostic
test
again.
3.
Reinstall
the
diagnostic
programs
(see
68
System
x3400
Types
7973,
7974,
7975,
and
7976:
Problem
Determination
and
Service
Guide
Содержание System x3400 Type 7973
Страница 1: ...System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Страница 8: ...vi System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Страница 18: ...xvi System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Страница 34: ...16 System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Страница 104: ...86 System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Страница 112: ...94 System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Страница 182: ...164 System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Страница 192: ...174 System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Страница 200: ...182 System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Страница 208: ...W weight 3 4 5 190 System x3400 Types 7973 7974 7975 and 7976 Problem Determination and Service Guide...
Страница 209: ......
Страница 210: ...Part Number 31R2197 Printed in USA 1P P N 31R2197...