background image

Cell Broadband Engine is a trademark of Sony Computer Entertainment, Inc., in
the United States, other countries, or both and is used under license therefrom.

Intel, Intel Xeon, Itanium, and Pentium are trademarks or registered trademarks of
Intel Corporation or its subsidiaries in the United States and other countries.

Java and all Java-based trademarks and logos are trademarks or registered
trademarks of Oracle and/or its affiliates.

Linux is a registered trademark of Linus Torvalds in the United States, other
countries, or both.

Microsoft, Windows, and Windows NT are trademarks of Microsoft Corporation in
the United States, other countries, or both.

UNIX is a registered trademark of The Open Group in the United States and other
countries.

Important notes

Processor speed indicates the internal clock speed of the microprocessor; other
factors also affect application performance.

CD or DVD drive speed is the variable read rate. Actual speeds vary and are often
less than the possible maximum.

When referring to processor storage, real and virtual storage, or channel volume,
KB stands for 1024 bytes, MB stands for 1,048,576 bytes, and GB stands for
1,073,741,824 bytes.

When referring to hard disk drive capacity or communications volume, MB stands
for 1,000,000 bytes, and GB stands for 1,000,000,000 bytes. Total user-accessible
capacity can vary depending on operating environments.

Maximum internal hard disk drive capacities assume the replacement of any
standard hard disk drives and population of all hard disk drive bays with the
largest currently supported drives that are available from IBM.

Maximum memory might require replacement of the standard memory with an
optional memory module.

Each solid-state memory cell has an intrinsic, finite number of write cycles that the
cell can incur. Therefore, a solid-state device has a maximum number of write
cycles that it can be subjected to, expressed as

total bytes written

(TBW). A

device that has exceeded this limit might fail to respond to system-generated
commands or might be incapable of being written to. IBM is not responsible for
replacement of a device that has exceeded its maximum guaranteed number of
program/erase cycles, as documented in the Official Published Specifications for
the device.

IBM makes no representation or warranties regarding non-IBM products and
services that are ServerProven

®

, including but not limited to the implied warranties

of merchantability and fitness for a particular purpose. These products are offered
and warranted solely by third parties.

34

1U Higher Voltage DC PDU (240V/380V): Installation and Maintenance Guide

Содержание System X High Voltage DC PDU

Страница 1: ...1U Higher Voltage DC PDU 240V 380V Installation and Maintenance Guide...

Страница 2: ......

Страница 3: ...1U Higher Voltage DC PDU 240V 380V Installation and Maintenance Guide...

Страница 4: ...ion document and the IBM Safety Information the Supplemental Safety Notice L015 and the Environmental Notices and User Guide documents on the IBM Documentation CD Second Edition July 2014 Copyright IB...

Страница 5: ...Getting help and information from the World Wide Web 30 How to send DSA data to IBM 30 Software service and support 31 Hardware service and support 31 IBM Taiwan product service 31 Notices 33 Trademar...

Страница 6: ...iv 1U Higher Voltage DC PDU 240V 380V Installation and Maintenance Guide...

Страница 7: ...dukt Lees voordat u dit product installeert eerst de veiligheidsvoorschriften Ennen kuin asennat t m n tuotteen lue turvaohjeet kohdasta Safety Information Avant d installer ce produit lisez les consi...

Страница 8: ...r information that is used in this documentation Important Each caution and danger statement in this documentation is labeled with a number This number is used to cross reference an English language c...

Страница 9: ...s product v When possible use one hand only to connect or disconnect signal cables v Never turn on any equipment when there is evidence of fire water or structural damage v Disconnect the attached pow...

Страница 10: ...rmation that is provided with your device for electrical specifications Statement 14 CAUTION Hazardous voltage current and energy levels might be present Only a qualified service technician is authori...

Страница 11: ...tion CD The IBM Documentation CD contains documentation for the PDU in Portable Document Format PDF and includes the IBM Documentation Browser to help you find information quickly Hardware and softwar...

Страница 12: ...s Crtl F to use the Acrobat search function or press Alt F to use the xpdf search function within the document Click Help for detailed information about using the Documentation Browser Notices and sta...

Страница 13: ...1U PDU see Chapter 2 Installing the 1U PDU vertically in a rack on page 7 v For horizontal mounting instructions of the 1U PDU see Chapter 3 Installing the 1U PDU horizontally in a rack on page 17 Inv...

Страница 14: ...l connect to the PDU do not come with the PDU 2 You will have some unused parts depending on how you install the PDU Features of the PDU The PDU has the following features v Wide input voltage range 1...

Страница 15: ...he breaker pole until it locks into place Note To manually disconnect power to a device that is connected to the PDU disconnect the device power cord from the PDU power outlet Input power cable You ar...

Страница 16: ...as a single load group as described in the following illustration and table 1 3 5 2 4 6 Table 1 PDU load group Circuit breaker number Associated front outlet 1 1 2 2 3 3 4 4 5 5 6 6 6 1U Higher Voltag...

Страница 17: ...on of this product during an electrical storm v Connect all power cords to a properly wired and grounded electrical outlet v Connect to properly wired outlets any equipment that will be attached to th...

Страница 18: ...ack side compartment must be between 48 6 cm 19 1 in and 56 9 cm 22 4 in apart If your rack has movable side braces see the rack documentation for information about relocating the side braces if they...

Страница 19: ...he bottom do not install the PDU with the front panel facing up or down or vertically with the cable end at the top Ground Ground Unsupported orientation Supported orientation Note v Removing the rack...

Страница 20: ...hen you install multiple devices in the rack To install a PDU in the side of a rack by using the vertical mounting brackets complete the following steps Procedure 1 Align the vertical mounting bracket...

Страница 21: ...ecure the power cord along the way If the power cord must exit the rack to connect to a power source use the openings in the rack Attention v You must disconnect the main input power before you connec...

Страница 22: ...ither the front or rear of the rack either horizontally or vertically with the cable end at the bottom do not install the PDU with the front panel facing up or down or vertically with the cable end at...

Страница 23: ...ir space provides proper airflow v Connect all power cords to properly wired and grounded electrical outlets v Do not overload the power outlet when you install multiple devices in the rack You must u...

Страница 24: ...ide of the rack then while you hold the PDU in place attach the brackets to the rack mounting flanges with four clip nuts and four M6 screws that come with the PDU 4 Route the power cord from the PDU...

Страница 25: ...hat only a Licensed Electrician installs or removes the PDU power cable from the DC Power source All National and Local building code requirements must be met IBM service technicians are not Licensed...

Страница 26: ...16 1U Higher Voltage DC PDU 240V 380V Installation and Maintenance Guide...

Страница 27: ...n a rack observe the following precautions v Make sure that the room air temperature is below 40 C 104 F v Do not block any air vents usually 15 cm 6 in of air space provides proper airflow v Plan the...

Страница 28: ...vice covers unless instructed otherwise in the installation and configuration procedures v Connect and disconnect cables as described in the following table when installing moving or opening covers on...

Страница 29: ...ble mounting rail b Secure the two adjustable mounting rail parts with three screws that come with the rack mounting kit 3 Align the adjustable mounting rails with the holes in the side rear of the PD...

Страница 30: ...of the PDU that has the short mounting brackets to the rack first Make sure that the short mounting brackets are aligned with the outside of the rack flanges Attach the brackets to the rack flanges wi...

Страница 31: ...e with the PDU 8 Route the power cord toward a dedicated power source Use the provided cable straps to secure the power cord along the way If the power cord must exit the rack to connect to a power so...

Страница 32: ...22 1U Higher Voltage DC PDU 240V 380V Installation and Maintenance Guide...

Страница 33: ...ail termination It has three stranded copper conductors each with a cross section of 25 sq mm approximately 2 AWG The PDU requires a high voltage dc power source between 240 V dc and 380 V dc with 90...

Страница 34: ...24 1U Higher Voltage DC PDU 240V 380V Installation and Maintenance Guide...

Страница 35: ...st be installed only by trained service technicians For information about the terms of the warranty and getting service and assistance see the Warranty Information document Attention You are responsib...

Страница 36: ...26 1U Higher Voltage DC PDU 240V 380V Installation and Maintenance Guide...

Страница 37: ...ipping and storage humidity 5 100 includes condensing Localized air temperature in PDU 40 6 C 105 F maximum Rated voltage rated current 192 400 V dc 90 amps Important The PDU input power connection mu...

Страница 38: ...28 1U Higher Voltage DC PDU 240V 380V Installation and Maintenance Guide...

Страница 39: ...ion within a software upgrade Determine whether the firmware and device drivers for the devices in the IBM Flex System Enterprise Chassis are up to date You can use the IBM Flex System Manager Update...

Страница 40: ...es go to http www ibm com supportportal You can find the most up to date information for the IBM Flex System product family at http pic dhe ibm com infocenter flexsys information index jsp Getting hel...

Страница 41: ...cate a reseller authorized by IBM to provide warranty service go to http www ibm com partnerworld and click Find Business Partners For IBM support telephone numbers see http www ibm com planetwide In...

Страница 42: ...32 1U Higher Voltage DC PDU 240V 380V Installation and Maintenance Guide...

Страница 43: ...ome states do not allow disclaimer of express or implied warranties in certain transactions therefore this statement may not apply to you This information could include technical inaccuracies or typog...

Страница 44: ...acity or communications volume MB stands for 1 000 000 bytes and GB stands for 1 000 000 000 bytes Total user accessible capacity can vary depending on operating environments Maximum internal hard dis...

Страница 45: ...the levels of particulates or gases in your environment have caused damage to the device IBM may condition provision of repair or replacement of devices or parts on implementation of appropriate remed...

Страница 46: ...r Federal Communications Commission FCC statement Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits...

Страница 47: ...may cause radio interference in which case the user may be required to take adequate measures Responsible manufacturer International Business Machines Corp New Orchard Road Armonk New York 10504 914 4...

Страница 48: ...se A Dieses Ger t ist berechtigt in bereinstimmung mit dem Deutschen EMVG das EG Konformit tszeichen CE zu f hren Verantwortlich f r die Einhaltung der EMV Vorschriften ist der Hersteller Internationa...

Страница 49: ...roducts greater than 20 A per phase Korea Communications Commission KCC statement This is electromagnetic wave compatibility equipment for business Type A Sellers and users need to pay attention to it...

Страница 50: ...40 1U Higher Voltage DC PDU 240V 380V Installation and Maintenance Guide...