Table 6. Troubleshooting information (continued)
Component
Problem indicator
Possible cause
Possible solutions
One or more hard
disk drives
One or more green
LEDs off
No activity to the
drives
No action is required.
All hard disk
drives
No activity to the
drives
No action is required.
Damaged or loose
SAS cables
Check the SAS cables and connections.
ESM failure
Use the RAID controller management software to
check the drive status. Replace the ESM. See
“Replacing an ESM” on page 35.
Midplane failure
Have the EXP2500 serviced.
Front panel
Power supply
Make sure that the cables are connected and the
power supplies are turned on.
Hardware failure
If any other LEDs are lit, have the EXP2500
serviced.
Some or all
components
Intermittent or
sporadic power loss to
the EXP2500
Defective ac or dc
power source or
partially connected
power cord
1. Check the ac or dc power source.
2. Secure all installed power cables and power
supplies.
3. If applicable, check the power components
(power supplies, uninterruptible power supply,
and so on).
4. Replace defective power cables.
Power-supply
failure
Check for a fault LED on the power supply and
replace the failed power supply. See “Replacing a
hot-swap power supply” on page 36.
Midplane failure
Have the EXP2500 serviced.
Drives
Unable to access any
drives
SAS cable
1. Make sure that the SAS cables are undamaged
and correctly connected.
2. Replace the cables.
ESM failure
Have the EXP2500 serviced.
Subsystem
Random errors
Midplane failure
Have the EXP2500 serviced.
42
System Storage EXP2512 and EXP2524: Installation and Maintenance Guide
Содержание System Storage EXP2512 Express Storage Enclosure
Страница 2: ......
Страница 10: ...viii System Storage EXP2512 and EXP2524 Installation and Maintenance Guide ...
Страница 28: ...16 System Storage EXP2512 and EXP2524 Installation and Maintenance Guide ...
Страница 56: ...44 System Storage EXP2512 and EXP2524 Installation and Maintenance Guide ...
Страница 66: ...54 System Storage EXP2512 and EXP2524 Installation and Maintenance Guide ...
Страница 70: ...58 System Storage EXP2512 and EXP2524 Installation and Maintenance Guide ...
Страница 71: ......
Страница 72: ... Part Number 90Y8809 Printed in USA GA32 0965 01 1P P N 90Y8809 ...