manualshive.com logo in svg
background image

Connect

 

the

 

cables

 

to

 

the

 

DS4000

 

Alert

 

Manager

 

Appliance

 

beginning

 

with

 

port

 

1

 

at

 

the

 

top

 

of

 

the

 

serial

 

card

 

(as

 

viewed

 

from

 

the

 

back

 

of

 

the

 

appliance).

 

Connect

 

the

 

subsystems

 

to

 

the

 

serial

 

ports

 

in

 

the

 

same

 

order

 

they

 

are

 

listed

 

in

 

the

 

data

 

collection

 

worksheet,

 

such

 

that

 

the

 

first

 

storage

 

server

 

listed

 

is

 

connected

 

to

 

ports

 

1

 

and

 

2.

 

Important:

 

Connect

 

serial

 

cables

 

for

 

storage

 

server

 

controller

 

pairs

 

in

 

adjacent

 

ports,

 

starting

 

with

 

an

 

odd-numbered

 

port

 

(port

 

1,

 

then

 

port

 

2,

 

3-4,

 

5-6,

 

7-8).

 

If

 

a

 

storage

 

server

 

with

 

a

 

single

 

controller

 

is

 

added,

 

connect

 

the

 

single

 

controller

 

to

 

the

 

odd-numbered

 

port

 

and

 

skip

 

the

 

following

 

even-numbered

 

port.

 

(For

 

example,

 

add

 

the

 

single

 

controller

 

to

 

port

 

1,

 

skip

 

port

 

2,

 

and

 

then

 

begin

 

connecting

 

the

 

next

 

storage

 

server

 

with

 

port

 

3.)

Note:

  

The

 

serial

 

cables

 

for

 

the

 

FAStT200

 

(machine

 

type

 

3542)

 

storage

 

server

 

have

 

the

 

same

 

connectors

 

at

 

both

 

ends.

 

When

 

connecting

 

the

 

DS4000

 

Alert

 

Manager

 

Appliance

 

to

 

a

 

FAStT200,

 

be

 

sure

 

to

 

connect

 

the

 

red-banded

 

end

 

of

 

the

 

serial

 

cable

 

to

 

the

 

serial

 

port

 

on

 

the

 

DS4000

 

Alert

 

Manager

 

Appliance.

 

 

8.

   

Ensure

 

that

 

all

 

storage

 

servers

 

to

 

be

 

monitored

 

by

 

the

 

DS4000

 

Alert

 

Manager

 

Appliance

 

are

 

powered

 

on

 

and

 

available

 

for

 

use.

 

 

9.

   

Connect

 

the

 

DS4000

 

Alert

 

Manager

 

Appliance

 

to

 

the

 

analog

 

telephone

 

line

 

at

 

the

 

installation

 

site.

 

Alert Manager
Appliance

  

Figure

 

3.

 

Serial

 

cable

 

connections

 

8

 

IBM

 

TotalStorage

 

DS4000

 

Alert

 

Manager

 

Appliance:

 

Planning

 

and

 

Installation

 

Guide

Содержание System Storage DS4000

Страница 1: ...IBM TotalStorage DS4000 Alert Manager Appliance Planning and Installation Guide GC26 7739 01...

Страница 2: ......

Страница 3: ...IBM TotalStorage DS4000 Alert Manager Appliance Planning and Installation Guide GC26 7739 01...

Страница 4: ...d the general information in Notices on page 11 Second Edition February 2005 Copyright International Business Machines Corporation 2005 All rights reserved US Government Users Restricted Rights Use du...

Страница 5: ...ou A danger statement is placed just before the description of a potentially lethal or extremely hazardous procedure step or situation v Caution These statements indicate situations that can be potent...

Страница 6: ...ire water or structural damage v Disconnect the attached power cords telecommunications systems networks and modems before you open the device covers unless instructed otherwise in the installation an...

Страница 7: ...viceable parts inside the device v Use of controls or adjustments or performance of procedures other than those specified herein might result in hazardous radiation exposure DANGER Some laser products...

Страница 8: ...d the power switch on the power supply do not turn off the electrical current supplied to the device The device also might have more than one power cord To remove all electrical current from the devic...

Страница 9: ...s the following label attached Hazardous voltage current and energy levels are present inside any component that has this label attached There are no serviceable parts inside these components If you s...

Страница 10: ...viii IBM TotalStorage DS4000 Alert Manager Appliance Planning and Installation Guide...

Страница 11: ...lation considerations 2 Installation process overview 3 Chapter 2 Installing the DS4000 Alert Manager Appliance 5 Handling static sensitive devices 5 Installing the DS4000 Alert Manager Appliance 5 Ad...

Страница 12: ...x IBM TotalStorage DS4000 Alert Manager Appliance Planning and Installation Guide...

Страница 13: ...Figures 1 Installing the release latch bracket assemblies 7 2 Attaching the rack support wheels 7 3 Serial cable connections 8 Copyright IBM Corp 2005 xi...

Страница 14: ...xii IBM TotalStorage DS4000 Alert Manager Appliance Planning and Installation Guide...

Страница 15: ...Tables 1 Subsystem details example 2 Copyright IBM Corp 2005 xiii...

Страница 16: ...xiv IBM TotalStorage DS4000 Alert Manager Appliance Planning and Installation Guide...

Страница 17: ...rtant These notices provide information or advice that might help you avoid inconvenient or problem situations v Attention These notices indicate possible damage to programs devices or data An attenti...

Страница 18: ...in your system documentation for instructions on how to use the diagnostic programs The troubleshooting information or the diagnostic programs might tell you that you need additional or updated device...

Страница 19: ...consulted in selecting a fire suppression system that provides the correct level of coverage and protection IBM designs and manufactures equipment to internal and external standards that require cert...

Страница 20: ...xviii IBM TotalStorage DS4000 Alert Manager Appliance Planning and Installation Guide...

Страница 21: ...igure the DS4000 Alert Manager Appliance during installation IBM Service will review the contents of the worksheet with you during the installation to verify that the information provided during the o...

Страница 22: ...ify information about each of the storage servers to be attached to the appliance in the table on page 2 of the worksheet Attention The storage server names given should match precisely the storage se...

Страница 23: ...r the equipment is installed IBM will monitor and provide maintenance for the equipment No local access to the equipment is required or provided Notes 1 If the DS4000 Alert Manager Appliance is being...

Страница 24: ...c You will be notified when configuration is complete and the appliance is operational 4 IBM TotalStorage DS4000 Alert Manager Appliance Planning and Installation Guide...

Страница 25: ...o build up around you v Handle the device carefully holding it by its edges or its frame v Do not touch solder joints pins or exposed printed circuitry v Do not leave the device where others can handl...

Страница 26: ...static protection until you have completed the installation of all hardware See Handling static sensitive devices on page 5 3 Install the support rails into the rack cabinet Refer to the rack mounting...

Страница 27: ...ct the serial cables from the multi port serial card in the DS4000 Alert Manager Appliance to each storage server controller as shown in Figure 1 You can identify the DS4000 Alert Manager Appliance sp...

Страница 28: ...following even numbered port For example add the single controller to port 1 skip port 2 and then begin connecting the next storage server with port 3 Note The serial cables for the FAStT200 machine t...

Страница 29: ...o complete the configuration Adding additional DS4000 storage servers to an existing DS4000 Alert Manager Appliance configuration The DS4000 Alert Manager Appliance can monitor up to four DS4000 stora...

Страница 30: ...10 IBM TotalStorage DS4000 Alert Manager Appliance Planning and Installation Guide...

Страница 31: ...TY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some jurisdictions do not allow dis...

Страница 32: ...s and population of all hard disk drive bays with the largest currently supported drives available from IBM Maximum memory may require replacement of the standard memory with an optional memory module...

Страница 33: ...nment products batteryrecycle shtml or contact your local waste disposal facility In the United States IBM has established a return process for reuse recycling or proper disposal of used IBM sealed le...

Страница 34: ...ence and 2 this device must accept any interference received including interference that may cause undesired operation Responsible party International Business Machines Corporation New Orchard Road Ar...

Страница 35: ...or SJT three conductor cord a maximum of 15 feet in length and a parallel blade grounding type attachment plug rated 15 amperes 125 volts For units intended to be operated at 230 volts U S use Use a...

Страница 36: ...16 IBM TotalStorage DS4000 Alert Manager Appliance Planning and Installation Guide...

Страница 37: ...mware requirements 3 6 H hardware service and support xvii heartbeat access permissions 2 I installation overview 3 planning 1 procedure 6 M maintenance 3 N notes important 12 notices electronic emiss...

Страница 38: ...18 IBM TotalStorage DS4000 Alert Manager Appliance Planning and Installation Guide...

Страница 39: ...in this book is Very Satisfied Satisfied Neutral Dissatisfied Very Dissatisfied Accurate h h h h h Complete h h h h h Easy to find h h h h h Easy to understand h h h h h Well organized h h h h h Appli...

Страница 40: ...Development Dept GZW 9000 South Rita Road Tuscon AZ U S A 85744 0001 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Страница 41: ......

Страница 42: ...Part Number 39M5580 Printed in USA GC26 7739 01 1P P N 39M5580...

Страница 43: ......

Страница 44: ......

Отзывы: