Attention:
v
Disk drive modules are fragile. Handle them with care. Keep them well away
from strong magnetic fields.
v
Any slot that has no disk drive module installed must contain a dummy disk
drive module. The dummy module ensures that the correct airflow is
maintained around the disk drive modules in the other slots. If a slot remains
empty, overheating may occur.
You do not need to remove power from the unit when exchanging a disk drive
module.
Before Exchanging a Disk Drive Module
1.
Check the lights on this disk drive module. (“Disk Drive Modules” on page 4
describes where these are, and how to see them.)
If the Check light is not on, you cannot exchange the disk drive module; call
your service representative and report the problem.
If the Check light is on, exchange the disk drive module for a new one using
the procedure described in the following section.
To Exchange a Disk Drive Module
1.
Pull upward on the latch
«1¬
and pull the handle
«2¬
of the failing disk drive
outward. This action disconnects the disk drive from the connector at the back
of the module and partially moves the module out of the slot.
2.
Attention:
Wait for twenty seconds to allow time for the disk drive motor to
stop.
3.
Carefully pull the module out of the unit. Support the module with your other
hand as you take it out of the unit.
Figure 20. Opening the Disk Drive Module Handle
18
ProFibre Storage Array: Operator’s Guide
Содержание StorageSmart DF1100J
Страница 2: ......
Страница 6: ...iv ProFibre Storage Array Operator s Guide...
Страница 22: ...12 ProFibre Storage Array Operator s Guide...
Страница 40: ...30 ProFibre Storage Array Operator s Guide...
Страница 42: ...32 ProFibre Storage Array Operator s Guide...
Страница 46: ...36 ProFibre Storage Array Operator s Guide...
Страница 48: ...38 ProFibre Storage Array Operator s Guide...
Страница 51: ......