Содержание ServeRAID-8 Series

Страница 1: ...ServeRAID 8 Series Best Practices and Maintenance Information...

Страница 2: ......

Страница 3: ...ServeRAID 8 Series Best Practices and Maintenance Information...

Страница 4: ...it supports read the general information in Notices on page 45 Second Edition September 2011 Copyright IBM Corporation 2008 2011 US Government Users Restricted Rights Use duplication or disclosure res...

Страница 5: ...rage Expansion Unit 3 14 Zero mode flash for ServeRAID 8k and ServeRAID 8k l System x3650 16 Zero mode flash for ServeRAID 8k and ServeRAID 8k l System x3550 18 Zero mode flash for ServeRAID 8k and Se...

Страница 6: ...Index 49 iv ServeRAID 8 Series Best Practices and Maintenance Information...

Страница 7: ...isplay lndocid SERV RAID brandind 5000008 or complete the following steps Note Changes are made periodically to the IBM Web site Procedures for locating firmware and documentation might vary slightly...

Страница 8: ...ort supportsite wss docdisplay brandind 5000008 lndocid MIGR 5073723 Type 5073723 in the Search field at http www ibm com Synchronizing logical drives after upgrading firmware from build 8263 or earli...

Страница 9: ...btain the storage management data as needed This is the only way that ServeRAID Manager 9 0 can manage a system with an earlier version of the device driver If the device driver is ever upgraded to ve...

Страница 10: ...ith ServeRAID firmware build 15407 and later managing hard disk drive write cache policies on the ServeRAID 8 series controllers is improved to make this a global controller setting so that all hard d...

Страница 11: ...8 series controller is treated as a replaced drive when the host server is restarted Defunct is a physical drive state in which the ServeRAID controller cannot communicate correctly with the drive Vis...

Страница 12: ...sting ServeRAID configuration information metadata The ServeRAID controller tries to use the existing information on the drive to recover the array The newly installed drive might appear as part of an...

Страница 13: ...other operations are completed The tools that are available from a graphical interface to modify tasks are on the IBM ServeRAID Support CD you must start to the CD and the operating system installable...

Страница 14: ...physical drive from the connector using the handle of the tray 5 Wait 45 seconds to allow the hard disk drive motor to completely stop spinning 6 Remove the defunct drive from the slot and insert the...

Страница 15: ...ry The symptoms that are generated by previous levels of PHY settings often have multiple origins therefore it is very important to apply all other updates and fixes before you consider the AMSU updat...

Страница 16: ...13 Evaluate the current AMSU settings for the servers that are listed in Table 1 Note You can check the AMSU settings by using the following arcconf getlogs command arcconf getlogs n uart filename txt...

Страница 17: ...e has failed v The ServeRAID controller is not seen during POST after a recent flash update v The flash update program returns an error code or failed message v The system loses power during a flash u...

Страница 18: ...jumper connector across the two pins that are shown in Figure 1 7 If you removed the controller in step 4 reinstall it 8 Insert the ServeRAID 8i firmware disk 1 into the diskette drive 9 Turn on the s...

Страница 19: ...Note Changes are made periodically to the IBM Web site Procedures for locating firmware and documentation might vary slightly from what is described in this document a Go to http www ibm com systems...

Страница 20: ...part number 39R7563 FRU 40K1739 v ServeRAID 8k SAS Controller part number 25R8064 v ServeRAID 8k l SAS Controller part number 39R8729 To perform a zero mode flash update complete the following steps...

Страница 21: ...cess If the zero mode jumper is installed correctly the ServeRAID 8k controller does not display a POST banner 12 As the system starts to diskette 1 the following message is displayed This program wil...

Страница 22: ...1 Obtain a 2 pin jumper connector 2 Obtain a USB diskette drive 3 Download and create the ServeRAID 8k flash diskettes from the IBM ServeRAID Support CD version 9 0 containing build 15407 or later or...

Страница 23: ...er 10 As the server starts to diskette 1 the following message is displayed This program will update the firmware on all IBM ServeRAID 8k controllers in the system Do you want to continue Y N 11 Type...

Страница 24: ...the ServeRAID Matrix Web site go to http www 304 ibm com systems support supportsite wss docdisplay lndocid SERV RAID brandind 5000008 or complete the following steps Note Changes are made periodical...

Страница 25: ...banner 10 As the server starts to diskette 1 the following message is displayed This program will update the firmware on all IBM ServeRAID 8k controllers in the system Do you want to continue Y N 11...

Страница 26: ...trix Web site go to http www 304 ibm com systems support supportsite wss docdisplay lndocid SERV RAID brandind 5000008 or complete the following steps Note Changes are made periodically to the IBM Web...

Страница 27: ...ight corner from the front of the server see Figure 6 Note The JP9 location is not labeled on the system board Figure 6 ServeRAID 8k and ServeRAID 8k l zero mode flash jumper JP9 System x3500 Chapter...

Страница 28: ...message is displayed This program will update the firmware on all IBM ServeRAID 8k controllers in the system Do you want to continue Y N 10 Type y to respond to the prompt and then follow the instruc...

Страница 29: ...ctions on the backplanes and system boards 2 Perform any required ServeRAID BIOS firmware and device driver updates 3 Perform any hard disk drive firmware updates 4 Perform a zero mode flash update if...

Страница 30: ...nt and deadmap value to the metadata of the surviving member drives of the array Unfortunately if the second drive fails almost simultaneously the controller immediately stops all metadata updates and...

Страница 31: ...es of the ServeRAID controllers as they recover from a defunct drive The RAID 5EE valid state transitions for single disk failures are listed in the following table Table 2 RAID 5EE valid state transi...

Страница 32: ...ny model v System x3850 type 8864 any model v System x3950 E type 8874 any model v System x3950 E type 8879 any model v System x3950 type 8872 any model v System x3950 type 8878 any model v xSeries 26...

Страница 33: ...information is listed in the change history of the hard disk drive firmware updates If a drive is marked Defunct by the ServeRAID controller and does not have the latest firmware the drive might not b...

Страница 34: ...are found If no errors occur or all errors are corrected the drive is considered healthy Unrecoverable errors might cause data loss arcconf task start n device ID_number verify Within the operating sy...

Страница 35: ...s initialization check the connections and retry If the drive does not complete initialization replace it This process irrevocably removes array and logical drive information from the disk You can ini...

Страница 36: ...eference on the IBM ServeRAID Support CD Critical Migrating A logical drive in a Critical state that is undergoing a logical drive migration LDM Degraded RAID level 6 and RAID level 60 moves to a Degr...

Страница 37: ...User s Reference on the IBM ServeRAID Support CD Okay The logical drive is working correctly It is in a good functional state Okay Revived The logical drive has recovered to a Okay Revived state This...

Страница 38: ...om an Okay revived state configuration Redundant RAID Level RAID 5EE v When a force online operation is performed on an Offline state logical drive that has two defunct physical drives in its configur...

Страница 39: ...s bootable arrays v Hot spare assignment is not allowed for arrays in the Revived state v The operating system might not boot correctly from an Offline Revived array To view the minimum number of driv...

Страница 40: ...Configuration Utility and then select Create Array The Array Properties window opens 3 Select the physical drives that are members of the previous configuration 4 Select the previous RAID level 5 Ent...

Страница 41: ...Chapter 1 ServeRAID 8 series best practices and maintenance information 35...

Страница 42: ...n Offline array to Online Critical Revived by using the BIOS ServeRAID Manager SRM GUI or the Adaptec RAID Controller Configuration ARCCONF Force Online operation option BIOS To force an Offline array...

Страница 43: ...d by using the SRM GUI complete the following steps 1 Right click an Offline logical drive 2 Select Force online 3 A warning message is displayed as shown in the following illustration Chapter 1 Serve...

Страница 44: ...umber logicaldrive logical_drive_number online noprompt 2 You are prompted with the following warning message before the force online operation is performed WARNING Forcing a logical drive online is n...

Страница 45: ...Adaptec BIOS Utility or in the IBM ServeRAID Manager application if you select an option that is not valid an Invalid Process error message is displayed For example in the Adaptec BIOS Utility if you...

Страница 46: ...operation fails the arcconf command exits and an applicable error message is displayed Displaying an Offline array in POST After powering on or restarting the server as the Adaptec BIOS information i...

Страница 47: ...logical drive or Identify logical drive Arcconf Only a delete logical drive operation can be performed on a Revived logical drive If you perform any other operation on the Revived drive other than a d...

Страница 48: ...ogical drive or Identify logical drive Arcconf Only a delete logical drive or force online operation can be performed on an Offline drive If you perform any other operation on an Offline drive other t...

Страница 49: ...c tests that you can perform Most systems operating systems and programs come with documentation that contains troubleshooting procedures and explanations of error messages and error codes If you susp...

Страница 50: ...In the U S and Canada call 1 800 IBM SERV 1 800 426 7378 Hardware service and support You can receive hardware service through your IBM reseller or IBM Services To locate a reseller authorized by IBM...

Страница 51: ...OR A PARTICULAR PURPOSE Some states do not allow disclaimer of express or implied warranties in certain transactions therefore this statement may not apply to you This information could include techni...

Страница 52: ...ands for approximately 1000 bytes MB stands for approximately 1 000 000 bytes and GB stands for approximately 1 000 000 000 bytes When referring to hard disk drive capacity or communications volume MB...

Страница 53: ...for a publication direct your mail to the following address Information Development IBM Corporation 205 A015 3039 E Cornwallis Road P O Box 12195 Research Triangle Park North Carolina 27709 2195 U S...

Страница 54: ...48 ServeRAID 8 Series Best Practices and Maintenance Information...

Страница 55: ...hard disk drive 27 maintenance updates for ServeRAID 9 Microsoft Windows upgrading ServeRAID Manager 9 0 3 mounting battery correctly ServeRAID 8k 24 N notes 1 notes important 46 notices 45 notices an...

Страница 56: ...44 write cache policy physical drive 4 Z zero mode flash for a ServeRAID 8i SAS PCI X Controller 11 for a ServeRAID 8s SAS SATA PCI e Controller 13 for ServeRAID 8k and ServeRAID 8k l BladeCenter Stor...

Страница 57: ......

Страница 58: ...Part Number 46M1375 Printed in USA 1P P N 46M1375...