unless 4 Gbps FC transceivers are used. As the 8 and 16 Gbps channel is more
sensitive to the condition of the existing multimode and single mode cable plant, it
is very important to minimize connector reflections and maintain an acceptable
link loss budget.
This section provides link troubleshooting advice on fault isolation and provides
guidance in the following areas:
v
Dust and dirt contamination
v
Link loss
v
Attenuation on LWL connections
Fault isolation
Since a job loss issue can be caused by a variety of problems, it is important to
employ a systematic fault isolation process to remedy the issue. Note that job
losses do not necessarily result from link errors. They may also be due to:
v
Configuration issues
v
Networking overload
v
Failures on storage device, switch, or server
Assume for these procedures that the observed errors originate from link errors
and are not the result of configuration issues, network overload or network
equipment failures.
Whenever CRC errors are discovered on a particular link, it is easy to jump to the
conclusion that the link is causing the network issue. This might not be the case.
Since CRC errors are just symptoms of a link issue, we need to trace the
propagated error to where it originated.
Figure 52 shows a simplified network involving a server, a switch, and a storage
device. In this example, assume that the server experienced an error at port 1. This
observable error can potentially originate from links 1, 2, 3, or 4 and/or SFP 1, 2, 3,
or 4.
To determine the original failing link, the observable CRC error needs to be
tracked back to the first occurrence of the CRC error. By this process, it is
discovered in this example that CRC errors observed in link 4 were propagated
from link 3, which in turn originated from link 2.
Once the original failing link (link 2) has been determined, the two connecting
ports of that link need to be checked for the errors:
v
Encoder errors
v
Disparity errors
v
Invalid transmission words
Server
Port
1
SFP
1
Tx
Rx
Switch
Port
5
Port
6
SFP
2
SFP
3
Rx
Tx
Tx
Rx
Storage
Port
9
SFP
4
Rx
Tx
Link 1
Link 4
Link 2
Link 3
b965036
Figure 52. Identifying the origin of failure
164
SAN768B-2 Installation, Service, and User Guide
Содержание SAN768B-2
Страница 2: ......
Страница 8: ...vi SAN768B 2 Installation Service and User Guide...
Страница 10: ...viii SAN768B 2 Installation Service and User Guide...
Страница 14: ...xii SAN768B 2 Installation Service and User Guide...
Страница 28: ...xxvi SAN768B 2 Installation Service and User Guide...
Страница 40: ...12 SAN768B 2 Installation Service and User Guide...
Страница 108: ...80 SAN768B 2 Installation Service and User Guide...
Страница 182: ...154 SAN768B 2 Installation Service and User Guide...
Страница 186: ...158 SAN768B 2 Installation Service and User Guide...
Страница 196: ...168 SAN768B 2 Installation Service and User Guide...
Страница 202: ...174 SAN768B 2 Installation Service and User Guide...
Страница 220: ...192 SAN768B 2 Installation Service and User Guide...
Страница 226: ...198 SAN768B 2 Installation Service and User Guide...
Страница 227: ......
Страница 228: ...Part Number 00MA746 Printed in USA GA32 0893 06 1P P N 00MA746...