System-error
LED
The
system-error
LED
is
illuminated
when
an
error
is
detected
by
the
system
board.
This
amber
LED
lights
up
if
the
SAN
Volume
Controller
hardware
detects
a
fatal
error
that
requires
a
new
field
replaceable
unit
(FRU).
Note:
Press
the
release
latch
to
view
the
light
path
diagnostic
panel,
which
will
help
you
to
isolate
the
faulty
FRU.
Information-Error
LED
When
the
information-error
LED
is
lit,
a
non-critical
event
has
occurred.
Check
the
light
path
diagnostics
panel
and
the
error
log.
Light
path
diagnostics
are
described
in
more
detail
in
the
light
path
maintenance
analysis
procedure
(MAP).
Location
LED
The
SAN
Volume
Controller
does
not
use
the
location
LED.
Hard
disk
drive
activity
LED
When
it
is
lit,
the
green
hard
disk
drive
activity
LED
indicates
that
the
hard
disk
drive
is
in
use.
Hard
disk
drive
activity
is
shown
on
the
hard
disk
drive
itself
and
also
on
the
hard
disk
drive
activity
LED.
Power
control
button
The
power
control
button
switches
on
or
switches
off
the
main
power
to
the
SAN
Volume
Controller
2145-8F2
or
SAN
Volume
Controller
2145-8F4.
To
turn
on
the
power,
press
and
release
the
power
control
button.
To
turn
off
the
power,
press
and
release
the
power
control
button.
Note:
If
you
press
the
power
control
button
and
do
not
release
it,
the
SAN
Volume
Controller
will
malfunction.
Power
LED
The
green
power
LED
indicates
the
power
status
of
the
SAN
Volume
Controller.
The
properties
of
the
green
power
LED
are
as
follows:
Off
One
or
more
of
the
following
are
true:
v
No
power
is
present
at
the
power
supply
input
v
The
power
supply
has
failed
v
The
LED
has
failed
On
The
SAN
Volume
Controller
is
powered
on.
Flashing
The
SAN
Volume
Controller
is
turned
off
but
is
still
connected
to
an
input
power
source.
Note:
A
power
LED
is
also
on
the
rear
of
the
server.
10
IBM
System
Storage
SAN
Volume
Controller:
Installation
Guide
|
|
Содержание SAN Volume Controller 2145-8F4
Страница 1: ...IBM System Storage SAN Volume Controller Installation Guide V ersion 4 1 0 GC26 7900 00...
Страница 2: ......
Страница 3: ...IBM System Storage SAN Volume Controller Installation Guide V ersion 4 1 0 GC26 7900 00...
Страница 8: ...vi IBM System Storage SAN Volume Controller Installation Guide...
Страница 74: ...44 IBM System Storage SAN Volume Controller Installation Guide...
Страница 78: ...48 IBM System Storage SAN Volume Controller Installation Guide...
Страница 120: ...90 IBM System Storage SAN Volume Controller Installation Guide...
Страница 122: ...92 IBM System Storage SAN Volume Controller Installation Guide...
Страница 128: ...98 IBM System Storage SAN Volume Controller Installation Guide...
Страница 134: ...104 IBM System Storage SAN Volume Controller Installation Guide...
Страница 138: ...108 IBM System Storage SAN Volume Controller Installation Guide...
Страница 141: ......
Страница 142: ...Part Number 31P0797 Printed in USA GC26 7900 00 1P P N 31P0797...
Страница 143: ...Spine information IBM System Storage SAN Volume Controller Installation Guide Version 4 1 0...