126
RS/6000 SP and Clustered IBM
^
pSeries Systems Handbook
If used, the adapter must be ordered as server feature code and it must be
installed in slot #6 of the server primary I/O drawer. Slot #7 must only be used for
the Internal Attachment Adapter (F/C 3154).
The SP Attachment Adapter uses an SP Switch cable to connect to an unused
switch port on the current SP configuration.
There are some SP-attached server placement limitations. Placement of the
SP-attached server is limited by the length of its following supplied cables:
1. The 10 m (33 ft.) frame-to-frame ground cable and RS/6000 SP System
Attachment adapter cable.
2. The 15 m (49 ft.) RS-232 cables.
Approximately 3 m (10 ft.) of cable is needed for the vertical portion of the cable
runs. Thus, the SP-attached server must be no more than 7 m (23 ft.) from the
SP frame and no more than 12 m (40 ft.) from the control workstation.
3.4.3 SP-attached server configurator rules
Ordering the SP-attached server requires the ordering of both SP features
(cables and installation instructions, as well as tracking for virtual nodes and
frames) and pSeries or RS/6000 features (SP LAN adapter, SP System
Attachement adapter - where attachment to the SP Switch is desired, F/C 3154
for M/T 7026, PSSP code).
Configuring the system order for an SP-attached server to an existing SP
system, consists of an MES order against the SP system to configure the
SP-attached server as part of the SP system.
Note: You must remove the plastic divider between slots 6 and 7 due to the
width of the SP-attachment adapter.
Note: You must order one of the following cables which connect the adapter to
a valid switch port.on the SP Switch:
10 m SP Switch/Switch or Switch/Node cable (F/C 9310).
20 m SP Switch to Switch cable (F/C 9320).
The cable must be ordered as part of the SP system.
Note: Refer to Chapter 10, “Clustering configurations” on page 285 for more
details about the SP-attached server environment.
Содержание RS/6000 SP
Страница 2: ......
Страница 6: ...iv RS 6000 SP and Clustered IBM pSeries Systems Handbook...
Страница 16: ...xiv RS 6000 SP and Clustered IBM pSeries Systems Handbook...
Страница 48: ...24 RS 6000 SP and Clustered IBM pSeries Systems Handbook...
Страница 58: ...34 RS 6000 SP and Clustered IBM pSeries Systems Handbook Figure 2 4 375 MHz POWER3 High Node packaging...
Страница 60: ...36 RS 6000 SP and Clustered IBM pSeries Systems Handbook Figure 2 5 375 Mhz POWER3 SMP Wide Node packaging...
Страница 100: ...76 RS 6000 SP and Clustered IBM pSeries Systems Handbook...
Страница 182: ...158 RS 6000 SP and Clustered IBM pSeries Systems Handbook...
Страница 218: ...194 RS 6000 SP and Clustered IBM pSeries Systems Handbook...
Страница 284: ...260 RS 6000 SP and Clustered IBM pSeries Systems Handbook...
Страница 387: ...Appendix A Naming convention 363 IBM RS 6000 7017 Model S70 7017 S70 S70 Node name Machine type M T Nickname used here...
Страница 388: ...364 RS 6000 SP and Clustered IBM pSeries Systems Handbook...
Страница 436: ...412 RS 6000 SP and Clustered IBM pSeries Systems Handbook...
Страница 477: ...0 1 spine 0 1 0 169 53 89 pages RS 6000 SP and Clustered IBM pSeries Systems Handbook...
Страница 478: ......
Страница 479: ......