2.
For an xSeries 330 server:
To set the remote alert attempts on the ASM
processor, log in to the ASM processor. For more information, see “Remote
Supervisor Adapter and ASM processor action descriptions” on page 7.
3. In the navigation pane, click
Alerts
and scroll down to the Monitored Alerts
section.
4. Select the events you want the Remote Supervisor Adapter or ASM processor
to monitor.
The remote alerts are categorized by the following levels of severity:
v
Critical
v
Warning
v
System
All alerts are stored in the event log and sent to all configured remote alert
recipients.
Critical alerts
Critical alerts are generated for events that signal that the server is no
longer functioning. If the
Select all critical alerts
check box is selected,
an alert can be sent for any critical alert.
Table 3. Critical remote alerts
Alphanumeric
pager code
Event
Action
00
Temperature irregularity Generates an alert if any of the monitored temperatures are outside
critical threshold values. To view the threshold values, click the
temperature readings on the System Health page. If a critical
temperature condition is detected, the server shuts down and turns off,
regardless of the alert notification setting.
01
Voltage irregularity
Generates an alert if the voltages of any of the monitored power supplies
fall outside their specified operational ranges. To view the operational
ranges, click the voltage readings on the System Health page. If a critical
voltage condition is detected, the server shuts down and turns off,
regardless of the alert notification setting.
02
Tampering
Generates an alert if physical intrusion of the server box is detected.
Tamper monitoring is not available on some servers, in which case this
setting is ignored.
03
Multiple fan failure
Generates an alert if two or more of the cooling fans in the server fail.
04
Power failure
Generates an alert if any of the server power supplies fail.
05
Hard disk drive failure
Generates an alert if one or more of the hard disk drives in the server
fail.
06
VRM failure
Generates an alert if one or more voltage regulator modules (VRMs) fail.
This setting is ignored for servers without VRMs.
07-09
Reserved for future use.
Warning alerts
Warning alerts are generated for events that might progress to a
critical/error level. If the
Select all warning alerts
check box is
selected, an alert can be sent for any warning alert.
Chapter 3. Configuring your Remote Supervisor Adapter or ASM processor
27
Содержание Remote Supervisor Adapter
Страница 1: ...Remote Supervisor Adapter User s Guide...
Страница 2: ......
Страница 3: ...Remote Supervisor Adapter User s Guide...
Страница 18: ...12 Remote Supervisor Adapter User s Guide...
Страница 60: ...54 Remote Supervisor Adapter User s Guide...
Страница 70: ...64 Remote Supervisor Adapter User s Guide...
Страница 102: ...96 Remote Supervisor Adapter User s Guide...
Страница 118: ...112 Remote Supervisor Adapter User s Guide...
Страница 122: ...116 Remote Supervisor Adapter User s Guide...
Страница 123: ......
Страница 124: ...Part Number 48P9833 Printed in U S A 1P P N 48P9833...