Complete the following steps to set the number of times the Remote Supervisor
Adapter or ASM processor attempts to send an alert:
1. Log in to the Remote Supervisor Adapter on which you want to set remote alert
attempts. For more information, see Chapter 2, “Opening and using the ASM
Web interface” on page 3.
2.
For an xSeries 330 server:
If you want to set the remote alert attempts on the
ASM processor, log in to the ASM processor. For more information, see
“Logging in to the ASM processor in an xSeries 330 server” on page 6.
3. In the navigation pane, click
Alerts
and scroll down to the Global Remote Alert
Settings section.
Use these settings to define the number of remote alert attempts and the time
between the attempts. The settings apply to all configured remote alert
recipients.
Remote alert retry limit
Use the
Remote alert retry limit
field to specify the number of
additional times that the Remote Supervisor Adapter or ASM processor
will attempt to send an alert to a recipient.
Delay between retries
Use the
Delay between retries
field to specify the time interval (in
minutes) that the Remote Supervisor Adapter or ASM processor will wait
between retries to send an alert to a recipient.
4. Select the
Include event log with e-mail alerts
check box to attach the local
event log to all e-mail alert notifications. The event log provides a summary of
the most recent events and assists with problem identification and fast recovery.
Notes:
a. To send the event log as an e-mail attachment, you must select E-mail over
LAN or E-mail over PPP as the notification method for at least one remote
alert recipient.
b. Event logs attached in an e-mail are not forwarded to a Remote Supervisor
Adapter on the ASM interconnect network.
5. Scroll to the bottom of the page and click
Save
.
Setting remote alerts
Note: For an xSeries 330 server:
You can set remote alerts only when you are
logged in to the ASM processor.
Complete the following steps to select the remote alerts to be sent:
1. Log in to the Remote Supervisor Adapter where you want to set remote alerts.
For more information, see Chapter 2, “Opening and using the ASM Web
interface” on page 3.
26
Remote Supervisor Adapter: User’s Guide
Содержание Remote Supervisor Adapter
Страница 1: ...Remote Supervisor Adapter User s Guide...
Страница 2: ......
Страница 3: ...Remote Supervisor Adapter User s Guide...
Страница 18: ...12 Remote Supervisor Adapter User s Guide...
Страница 60: ...54 Remote Supervisor Adapter User s Guide...
Страница 70: ...64 Remote Supervisor Adapter User s Guide...
Страница 102: ...96 Remote Supervisor Adapter User s Guide...
Страница 118: ...112 Remote Supervisor Adapter User s Guide...
Страница 122: ...116 Remote Supervisor Adapter User s Guide...
Страница 123: ......
Страница 124: ...Part Number 48P9833 Printed in U S A 1P P N 48P9833...