1.
Turn on the server.
Note:
Approximately 1 to 3 minutes after the server is connected to ac power,
the power-control button becomes active.
2.
When the prompt
<F1> Setup
is displayed, press F1.
3.
From the Setup utility main menu, select
Boot Manager
.
4.
Select
Add Boot Option
; then, select
USB Storage
. Press Enter, and then press
Esc.
5.
Select
Change Boot Order
and then select
Commit Changes
; then, press Enter.
6.
Select
Save Settings
and then select
Exit Setup
.
If the embedded hypervisor flash device image becomes corrupted, you can use
the
VMware Recovery
CD that comes with the server to recover the flash device
image. To recover the flash device image, complete the following steps:
1.
Turn on the server.
Note:
Approximately 1 to 3 minutes after the server is connected to ac power,
the power-control button becomes active.
2.
Insert the VMware Recovery CD into the CD or DVD drive.
3.
Follow the instructions on the screen.
For additional information and instructions, see the
VMware ESXi Server 31
Embedded Setup Guide
at http://www.vmware.com/pdf/vi3_35/esx_3i_e/r35/
vi3_35_25_3i_setup.pdf
Enabling the Broadcom Gigabit Ethernet Utility program
The Broadcom Gigabit Ethernet Utility program is part of the server firmware. You
can use it to configure the network as a startable device, and you can customize
where the network startup option appears in the startup sequence. Enable and
disable the Broadcom Gigabit Ethernet Utility program from the Setup utility.
Configuring the Broadcom Gigabit Ethernet controller
The Ethernet controllers are integrated on the system board. They provide an
interface for connecting to a 10 Mbps, 100 Mbps, or 1 Gbps network and provide
full-duplex (FDX) capability, which enables simultaneous transmission and
reception of data on the network. If the Ethernet ports in the server support
auto-negotiation, the controllers detect the data-transfer rate (10BASE-T,
100BASE-TX, or 1000BASE-T) and duplex mode (full-duplex or half-duplex) of the
network and automatically operate at that rate and mode.
You do not have to set any jumpers or configure the controllers. However, you
must install a device driver to enable the operating system to address the
controllers. For device drivers and information about configuring the Ethernet
controllers, see the
Broadcom NetXtreme II Gigabit Ethernet Software
CD. To find
updated information about configuring the controllers, go to http://
www.ibm.com/supportportal/.
108
IBM System x3850 X5 and x3950 X5 Types 7145, 7146, 7143, and 7191: Installation and User's Guide
Содержание Redbooks x3850 X5
Страница 1: ...IBM System x3850 X5 and x3950 X5 Types 7145 7146 7143 and 7191 Installation and User s Guide...
Страница 2: ......
Страница 3: ...IBM System x3850 X5 and x3950 X5 Types 7145 7146 7143 and 7191 Installation and User s Guide...
Страница 14: ...xii IBM System x3850 X5 and x3950 X5 Types 7145 7146 7143 and 7191 Installation and User s Guide...
Страница 42: ...28 IBM System x3850 X5 and x3950 X5 Types 7145 7146 7143 and 7191 Installation and User s Guide...
Страница 108: ...94 IBM System x3850 X5 and x3950 X5 Types 7145 7146 7143 and 7191 Installation and User s Guide...
Страница 128: ...114 IBM System x3850 X5 and x3950 X5 Types 7145 7146 7143 and 7191 Installation and User s Guide...
Страница 132: ...118 IBM System x3850 X5 and x3950 X5 Types 7145 7146 7143 and 7191 Installation and User s Guide...
Страница 146: ...132 IBM System x3850 X5 and x3950 X5 Types 7145 7146 7143 and 7191 Installation and User s Guide...
Страница 147: ......
Страница 148: ...Part Number 81Y1248 Printed in USA 1P P N 81Y1248...