Monitoring the iBBU with the MegaRAID Configuration Utilities
6-9
6.1.3
Monitoring the iBBU with the MegaRAID Storage Manager
When MegaRAID Storage Manager software is running, you can monitor
the status of all of the BBUs connected to controllers in the server. If a
BBU is operating normally, the icon looks like this: If it has
failed, a red dot appears next to the icon.
To show the properties for a BBU, perform the following steps:
1. Click the
Physical
tab to open the physical view.
2. Select the BBU icon in the left panel.
3. Click the
Properties
tab.
The BBU properties, such as the battery type, temperature, and voltage,
appear, as shown in
.
Description
Sets the BBU properties on the selected controller(s) after reading from the file.
The information displays in the following formats:
autoLearnPeriod = 1800Sec
nextLearnTime = 12345678Sec Seconds past 1/1/2000
learnDelayInterval = 24hours Not greater than 7 days
autoLearnMode = 0 0 – Enabled, 1 - Disabled, 2 – WarnViaEvent.
1. NOTE: You can change only two of these parameters, learnDelayInterval and
autoLearnMode.
Table 6.8
Set BBU Properties (Cont.)