Note:
Some versions of IBM i require that the gateway address respond to pings before the
console LAN adapter activates. Configure the PC with the default gateway IP address by
completing the following steps:
1)
Set the IP address to the
opcon
LAN adapter gateway.
2)
Set the subnet mask to the
opcon
LAN adapter subnet.
3)
Set the default gateway to the
opcon
LAN adapter primary router, or gateway address. This
address is the same address as the IP address.
4.
Disable the PC firewall.
Note:
All PC firewalls must be disabled for the initial connection.
To disable the PC firewall, complete the following steps:
a.
In the Windows control panel, click
Firewall settings
and disable the firewall.
b.
In the Windows control panel, click
Security center
. Check for a firewall and, if present, disable it.
c.
Scan all tasks that are unning on the PC for any other software firewalls and disable the firewall.
5.
Configure Operations Console on your system:
a.
Start Operations Console. To start the Operations Console, select
Start
>
All Programs
>
IBM
iSeries
>
Access
>
Operations Console
.
b.
Start the Configuration Wizard. If this is the first time Operations Console is started, the
connection wizard starts automatically. If it does not start automatically, click
Connection
>
New
Connection
to manually start the wizard. Read the notifications, and click
Next
.
c.
Select the local console on a network. Click
Next
.
d.
Specify a service host name and IP address by doing the following types:
1)
Give your session a name. The name must be one of the following names:
v
A valid host name that was registered in the site DNS for the console IP address
v
A unique name that you create that is not currently registered in the DNS for any other IP
address.
2)
If you are using IBM i V6R1 and later, press the Tab key. The
Service TCP/IP Address
field is
enabled.
3)
Specify the service TCP/IP address. Enter the LAN console adapter IP address.
4)
Click
Next
.
e.
Specify the LAN console interface information.
1)
In the
Service TCP/IP Address
field, type the IP address that you recorded.
2)
In the
Service Subnet Mask
field, type the subnet mask that you recorded.
3)
In the
Service gateway address
field, type the default gateway that you recorded.
4)
The system serial number must match the tag on the server. It must be 7 characters long,
without a dash.
5)
Set the
Target partition
to 1.
6)
Click
Next
.
f.
Specify the device ID. If you are prompted to specify a service tools device ID, enter
QCONSOLE
.
Click
Next
.
g.
Click
Next > Finish
. Your session is now ready to connect. Double-click the session name to start
the connection.
6.
Power on the server by completing the following steps:
a.
Set the manual initial program load (IPL) by completing the following steps:
1)
Locate the server's control panel. Look for the blue tab on the front of the server. Push it to the
side, and pull the control panel out slowly.
2)
Press the Up arrow key until you see
02
, and press Enter.
3)
Press Enter again. A
<
(less than symbol) appears next to the
N
.
Installing the IBM Power System S822 (8284-22A)
15
Содержание Power System 8284-22A
Страница 1: ...Power Systems Installing the IBM Power System S822 8284 22A GI11 9906 00 ...
Страница 2: ......
Страница 3: ...Power Systems Installing the IBM Power System S822 8284 22A GI11 9906 00 ...
Страница 6: ...iv Power Systems Installing the IBM Power System S822 8284 22A ...
Страница 14: ...xii Power Systems Installing the IBM Power System S822 8284 22A ...
Страница 46: ...32 Power Systems Installing the IBM Power System S822 8284 22A ...
Страница 54: ...40 Power Systems Installing the IBM Power System S822 8284 22A ...
Страница 65: ......
Страница 66: ... Part Number 00LA014 Printed in USA GI11 9906 00 1P P N 00LA014 ...