![IBM Power System 8284-21A Скачать руководство пользователя страница 44](http://html.mh-extra.com/html/ibm/power-system-8284-21a/power-system-8284-21a_installing_606024044.webp)
f.
Specify the device ID. If you are prompted to specify a service tools device ID, enter
QCONSOLE
.
Click Next.
g.
Click Next > Finish. Your session is now ready to connect. Double-click the session name to start
the connection.
7.
Power on the server by completing the following steps:
a.
Set the manual initial program load (IPL) by completing the following steps:
1)
Locate the server's control panel. Look for the blue tab on the front of the server. Push it to the
side, and pull the control panel out slowly.
2)
Press the Up arrow key until you see 02, and press Enter.
3)
Press Enter again. A < (less than symbol) appears next to N.
4)
Press the Up Arrow key. The N changes to an M.
5)
Press Enter.
6)
Press Enter twice. A 02 is displayed on the control panel.
b.
After you have the server set to a manual IPL, push the white power button to power on the
server.
Note:
You must watch the control panel while the system is trying to power on. During the IPL, the
system displays C6004031 indicating that it is searching for console. The system might take 20 - 30
minutes to complete this action. If A6005008 is displayed, this means that no console is available. This
might indicate that the system is not preinstalled with IBM i and you must set the console type to
LAN.
8.
Perform this step if the system is not preinstalled with IBM i. For setting the console type to LAN,
complete the following steps:
a.
Set the control panel to manual mode. If the system is in Normal mode (function 01 shows 01 B
N), select function 02 on the control panel and press Enter.
b.
Enable control panel functions by completing the following steps:
1)
Select function 25 on the control panel and press Enter. The return code must be 00.
2)
Select function 26 on the control panel and press Enter.
Note:
If you see a FF return code, go back to function 25 and press Enter, then return to
function 26 and press Enter.
c.
Check your current setting(s). Use console service functions (65+21+11) to check the current
setting.
v
A600 500A = No console defined
v
A601 500A = Twinax console
v
A602 500A = Direct cable console
v
A603 500A = LAN console
v
A604 500A = HMC console
If the system reference code (SRC) = A603500A, skip to step e. For all others SRCs, continue with
the next step.
d.
Set console type to LAN.
1)
Use the 65+21+11 sequences until it returns A603500B. This indicates that the console type will
be changed to LAN.
2)
Use the 21+11 sequences, if it returns A6C3500C. This indicates that settings have been saved
successfully. If not, repeat function 11 until it returns A6C3500C
e.
Clear the adapter configuration from the profile by completing the following steps:
1)
Use the 65+21+11 sequences until it returns A6C3500B. This indicates that the adapter
configuration will be cleared.
28
Power Systems: Installing the IBM Power System S812 (8284-21A)
Содержание Power System 8284-21A
Страница 1: ...Power Systems Installing the IBM Power System S812 8284 21A GI11 9925 00 IBM ...
Страница 2: ......
Страница 3: ...Power Systems Installing the IBM Power System S812 8284 21A GI11 9925 00 IBM ...
Страница 6: ...iv Power Systems Installing the IBM Power System S812 8284 21A ...
Страница 16: ...xiv Power Systems Installing the IBM Power System S812 8284 21A ...
Страница 60: ...44 Power Systems Installing the IBM Power System S812 8284 21A ...
Страница 61: ......
Страница 62: ...IBM Part Number 01LK518 Printed in USA GI11 9925 00 1P P N 01LK518 ...