background image

 

 

 

Control or Screen View service and asking whether you want to permit
this user to use this service on your system. You can click Yes or No.
If you do not make a selection within 15 seconds (for example, if you
are not sitting at your system when the access attempt is made),
Netfinity Manager will automatically prevent the remote user from using
the service on your system.

Ÿ

Disable DNS Name Resolution

If the Disable DNS Name Resolution option is enabled, Netfinity
Manager will use only a numeric TCP/IP address (for example,
8.24.67.32) to communicate with remote systems and will not attempt
to resolve the numeric address into an alphanumeric Domain Name
Server (DNS) address (for example, your.system.ibm.com). Select this
option if you are using Netfinity Manager in a WINS networking
environment or if you are using TCP/IP in an environment that does not
have a Domain Name Server.

To implement one or more of the available Netfinity Manager Options:

  1) Click Options....

2) Select the Netfinity Manager options to be enabled.

  3) Click Save.

f. Set the Network Timeout Value (optional).

The Network Timeout field shows the number of seconds that Netfinity
Manager will attempt to communicate with a remote system that is not
responding. If Netfinity Manager does not establish contact with the remote
system within this time, it cancels the communication attempt. The
Network Timeout default setting is 15 seconds. This default setting might
not need to be altered.

g. Save the configuration and continue.

Click Save to save the configuration. Then, click Exit to continue.

Note:  The configuration can be changed later by double-clicking the

Network Driver Configuration object in the Netfinity folder.

12. After finishing configuring the system for network access, the installation

program displays a list of changes that must be made to the system
configuration files, and asks whether the installation program should make the
changes. For example, if Netfinity Manager for Windows 95 is being installed,
the installation program will display a list of changes that must be made to the
CONFIG.SYS file.

Click either Yes or No.

Note:  These changes must be made to the system configuration for Netfinity

Manager to run correctly.

Ÿ

If you click Yes the changes are automatically made to the system
configuration.

Ÿ

If you click No the commands are saved to a file named CONFIG.NEW in
the destination directory (and to AUTOEXEC.NEW, if appropriate) so that
they can be added later.

13. The installation is now complete. Shut down and restart the system for the

system configuration changes to take effect.

44

Netfinity

 4000R User's Handbook 

 

Содержание NETFINITY 4000R

Страница 1: ...IBM IBM Netfinity 4000R User s Handbook...

Страница 2: ......

Страница 3: ...IBM IBM Netfinity 4000R User s Handbook...

Страница 4: ...e periodically made to the information herein these changes will be incorporated in new editions of the publication IBM may make improvements and or changes in the product s and or the program s descr...

Страница 5: ...g the server 18 Removing the server from the rack 21 Chapter 3 Using the setup utility 23 Chapter 4 Installing the operating system 25 What you need 25 What to do 25 Chapter 5 Solving problems 29 Gene...

Страница 6: ...ation options 67 Automated installation 67 Customized installation 68 Section 3 Appendixes 71 Appendix A Help and service information 73 Step 1 Troubleshooting 73 Step 2 Preparing for the service call...

Страница 7: ...z les consignes de s curit Vor der Installation dieses Produkts die Sicherheitshinweise lesen Prima di installare questo prodotto leggere le Informazioni sulla Sicurezza Lees voordat u dit product ins...

Страница 8: ...abel attached Hazardous voltage current and energy levels are present inside any component that has this label attached There are no serviceable parts inside these components If you suspect a problem...

Страница 9: ...when there is evidence of fire water or structural damage Disconnect the attached power cords telecommunications systems networks and modems before you open the device covers unless instructed otherwi...

Страница 10: ...amage to programs devices or data An attention notice is placed just before the instruction or situation in which damage could occur Caution These notices indicate situations that can be potentially h...

Страница 11: ...onnectors 9 Front View 9 Back View 11 Chapter 2 Installing the server in the rack enclosure 13 What you will need 13 Preparing the server 14 Preparing the rack 15 Installing the server 18 Removing the...

Страница 12: ...2 Netfinity 4000R User s Handbook...

Страница 13: ...date information about your Netfinity server model and other IBM Netfinity server products at the following address http www ibm com netfinity Inventory list You should have the following items One N...

Страница 14: ...channel UltraWide SCSI adapter in full length slot controlling the hard disk drives One half length slot Upgradable microcode BIOS code upgrades when available can update EEPROMs on the system board4...

Страница 15: ...ides error correcting code ECC support for 100 MHz SDRAM memory Integrated network environment support Your Netfinity 4000R comes with two 10 100 Mbps Ethernet Controllers on the system board Each Eth...

Страница 16: ...ror checking and correcting ECC memory Error codes and messages Upgradable BIOS Automatic restart after power failure Parity checking on the SCSI bus and serial ports Monitoring and reporting the stat...

Страница 17: ...lled in the rack Notes 1 You must connect the power cord of each IBM Netfinity 4000R to a properly grounded PDU See the ServerProven list at http www ibm com pc netfinity to locate a PDU 2 For air flo...

Страница 18: ...V ac Maximum 137 V ac High range Minimum 180 V ac Maximum 265 V ac Input kilovolt amperes kVA approximately Maximum configuration as shipped 0 3 kVA Acoustical noise emission values8 Average sound pr...

Страница 19: ...ou have pressed the power on switch the power cord is not connected or the power supply has failed 3 1 Ethernet 1 This yellow LED lights when there is transaction activity on Ethernet port 1 4 2 Ether...

Страница 20: ...CD from the CD ROM drive Note If the CD tray does not extend insert the end of a straightened paper clip into the manual tray release opening and gently pull the tray open 14 CD ROM drive in use light...

Страница 21: ...USB connector 1 Reserved 9 Universal Serial Bus USB connector 2 Reserved 1 PCI slot 1 This slot contains the SCSI controller for the hard disk drives You can connect an IBM approved external tape driv...

Страница 22: ...Controls indicators and connectors 16 Option 2 Reserved 17 Option 1 Reserved 18 Power cord connector Attach the power cord here 12 Netfinity 4000R User s Handbook...

Страница 23: ...air flow reasons when IBM Netfinity 4000Rs are mounted in succession in a rack there must be no intervening spaces between the IBM Netfinity 4000Rs 4 CAUTION Use safe practices when lifting This chap...

Страница 24: ...ve the two screws from the right side of the server 3 Attach the inner slide section of each slide rail assembly to the side of the server a Pull the inner slide from each slide rail assembly until th...

Страница 25: ...he rack enclosure 4 If you are installing multiple servers in the rack install all the nut bars and slide rails for all the servers first then install each server in the rack 5 Review the documentatio...

Страница 26: ...ck rail and the nut bar c Tighten the screws until the nut bar is approximately 4 mm 16 in from the rack rail 4 Attach nut bars to the other three corners of the U unit in the same way 5 Attach the sl...

Страница 27: ...e rail to fit the rack Tighten the adjustment screws 3 c Push the slide bracket assemblies to the outermost positions on the rack Make sure that the slides on the slide rail assembly will extend out f...

Страница 28: ...onto the outer slide about 5 cm 2 in until the server stops d Press the safety latches 1 on the slide rails and slide the server further onto the outer slide until the slide rails click into place e P...

Страница 29: ...ing them through the slot in the server mounting flange the mounting rail the slide rail assembly bracket and the nut bar Tighten the screws 3 Connect the console bus cable 1 to the console bus In por...

Страница 30: ...ect the other end of the power cord to a properly grounded power distribution unit PDU See the ServerProven list at http www ibm com pc netfinity to locate a PDU 7 Connect the keyboard mouse and monit...

Страница 31: ...rom the rear of the server 4 On each side of the server front remove the screw holding the mounting flange to the rack the top screw 5 Pull the server forward until the safety latch on the slide rails...

Страница 32: ...22 Netfinity 4000R User s Handbook...

Страница 33: ...highlighted option Press the Esc key to return to the Setup Utility main menu Menu item Items you can change Standard CMOS Setup Date and time Advanced CMOS Setup BootUp Num Lock on or off Password C...

Страница 34: ...you can change Save Settings and Exit Save any changes you made and exit the setup utility Exit Without Saving Exit the setup utility without saving any changes you might have made 24 Netfinity 4000R...

Страница 35: ...elcome to Setup window press Enter The system displays a list of recognized hardware 3 Press Enter to accept the recognized hardware in the list 4 If the system displays a window discussing the number...

Страница 36: ...ork information as requested 14 When the Display Settings window is displayed accept the standard settings You will address the video information later in this procedure 15 Follow the instructions to...

Страница 37: ...in Click Continue 22 After the driver has been copied remove the Netfinity 4000R System CD and click the Yes button to restart the system 23 When the system restarts and displays the New graphics driv...

Страница 38: ...28 Netfinity 4000R User s Handbook...

Страница 39: ...on self test POST Each time you turn on your server it performs a series of tests that check the operation of the base computer This series of tests is called the power on self test POST POST does the...

Страница 40: ...s Ctrl A during startup on the drive Attention A low level format will erase any data on the drive If you are not willing to perform a low level format or if the format did not correct the problem fol...

Страница 41: ...Run the setup utility and save the settings see Chapter 3 Using the setup utility on page 23 CMOS Time and Date Not Set The date and time are not set in CMOS Action Run the setup utility and set the d...

Страница 42: ...xt messages but they also can be numeric messages For information about these software error messages refer to the information that comes with the operating system or application program or both Diagn...

Страница 43: ...Netfinity Manager Lotus Notes database 51 ODBC database support 52 System requirements 52 ODBC database configuration 52 Creating the Netfinity tables 53 Supported and certified databases 55 Chapter 1...

Страница 44: ...s 63 System Profile 63 Update Connector Manager 63 Web Manager Configuration 64 Delaying Netfinity Manager startup on OS 2 systems 64 Chapter 11 Getting more information about Netfinity Manager 65 Cha...

Страница 45: ...tems in the managing system network from a system that is not attached to the managing system network Serial Connection Control Use the Serial Connection Control service to use a Netfinity Manager sys...

Страница 46: ...y Manager CD that comes with your server These documents are provided in Adobe Acrobat format PDF For more information on included documentation see Chapter 11 Getting more information about Netfinity...

Страница 47: ...e from Microsoft Note Systems using Netfinity Manager with Microsoft SNA Server cannot communicate with systems running the Microsoft SNA Server client Netfinity Manager supports only server to server...

Страница 48: ...38 Netfinity 4000R User s Handbook...

Страница 49: ...ton menu 5 Type x WINNT MANAGER NETFINST where x is the drive letter of the CD ROM drive in the Command Line field and then click OK 6 Choose a drive and directory from which the Netfinity Manager pro...

Страница 50: ...r more information on Advanced System Management and the Dynamic Connection Manager service see the Advanced System Management Information section of this server library Capacity Manager Click Capacit...

Страница 51: ...ble only on systems running Windows 95 or later or Windows NT 4 0 or later Capacity Management available only on systems running Windows NT 4 0 or later Cluster Manager available only on systems runni...

Страница 52: ...Driver Configuration Window Follow these steps to continue configuring the system a Enter a System Name Enter a name for the system in the System Name field This name will help other Netfinity Manager...

Страница 53: ...rations Available options include If the Force Remote Logons option is enabled the system will not be able to save the User ID Password combinations that were used when accessing remote systems This w...

Страница 54: ...at is not responding If Netfinity Manager does not establish contact with the remote system within this time it cancels the communication attempt The Network Timeout default setting is 15 seconds This...

Страница 55: ...ata can be exported from these Netfinity Manager services Alert Manager Software Inventory System Information Tool System Profile System Monitor Information on how to install and configure support for...

Страница 56: ...support so the tables can be configured For information on configuring the database for ODBC refer to ODBC database configuration on page 52 For information on creating the tables refer to Creating t...

Страница 57: ...the DB2 command window type the following command DB2 BIND x directory DB2SQLC0 bnd where x directory is the name of the drive and directory where Netfinity Manager is installed c Press Enter Granting...

Страница 58: ...stem 1 Use the GRANT EXECUTE command to enable Netfinity Manager to access the database Type the following command at the OS 2 prompt DB2 GRANT EXECUTE ON PACKAGE NETFIN DB2SQLC TO PUBLIC and then pre...

Страница 59: ...using a remote database catalog the node the database resides on and then catalog the database to that node Once this step has been completed the name of the Netfinity Manager database will appear in...

Страница 60: ...on page 55 Lotus Notes client refer to Table 2 on page 55 See the Notes Administrator s Guide for general system requirements and supported communications protocols Installing the database To enable...

Страница 61: ...the Lotus Notes directory path is included in the Global Windows NT environment settings If the system is running Netfinity Manager for Windows 95 ensure that the Lotus Notes directories are included...

Страница 62: ...S refer to Table 2 on page 55 IBM DB2 Microsoft SQL Server Windows 95 with ODBC refer to Table 2 on page 55 ODBC support for one or more of the following database management systems DBMS refer to Tabl...

Страница 63: ...matic in the Startup Type button group d Click This Account in the Log On As field group Enter in the This Account field the user name of the account that made this database an ODBC source e Click OK...

Страница 64: ...o a database for a specified user ID To grant access a Click Grant b In the User ID field type the user ID that will be permitted to access the database c Select privileges for this ID All privileges...

Страница 65: ...le 2 Page 1 of 2 Supported Netfinity Databases Reference by operating system and database client version Product Windows 95 Windows NT 3 51 Windows NT 4 0 OS 2 Warp Connect OS 2 Warp 4 0 IBM DB2 Versi...

Страница 66: ...arp Connect OS 2 Warp 4 0 Oracle Version 8 0 Yes Oracle Driver Version 8 0 3 0 0 No Yes Oracle Driver Version 8 0 3 0 0 No No Sybase SQL Version 11 0 Yes Sybase Driver Version 10 0 3T4 Yes Sybase Driv...

Страница 67: ...Database Tables object which contains a handy online reference for all of the data tables in the Netfinity Manager database For more information on Netfinity Manager database support see Chapter 9 Ne...

Страница 68: ...m configurations These services are Alert on LAN Configuration available only on systems running Windows 95 or later or Windows NT 4 0 or later Capacity Management available only on systems running Wi...

Страница 69: ...t to another system executing a program playing a WAV file available only on multimedia systems generating an SNMP alert message dialing out to a digital pager service available only on systems that h...

Страница 70: ...up allows for monitoring of ECC memory single bit errors and can automatically scrub or correct the ECC memory when errors are detected Also a running count of single bit errors can be kept and can se...

Страница 71: ...mote Session to establish a fully active command session with any remote Netfinity Manager system Remote System Manager Use Remote System Manager to access and manage any Netfinity Manager service on...

Страница 72: ...ion of this server library Note Although Advanced System Management is not included with or supported on the IBM Netfinity 4000R the IBM Netfinity 4000R can manage servers that have an IBM Advanced Sy...

Страница 73: ...dling both locally and remotely Individual files and entire directories can be renamed or deleted from the system partition Individual files can be renamed deleted or copied into the system partition...

Страница 74: ...use to specify the number of seconds that NETFBASE EXE will wait before starting During Netfinity Manager installation the Netfinity Network Interface object is placed in the Startup folder To configu...

Страница 75: ...on how to use Netfinity Manager NFMGRCR PDF Netfinity Manager Command Reference Detailed information on Netfinity Manager command line functions NFCSVCQB PDF Client Services for Netfinity Manager Quic...

Страница 76: ...66 Netfinity 4000R User s Handbook...

Страница 77: ...ource directory to distribute Netfinity Manager Services for OS 2 copy all of the files from the OS2 SERVICES directory into the created directory To create a source directory for a Netfinity Manager...

Страница 78: ...NETFBASE RSP from the directory Y NETFIN to drive C the directory to which the files are installed is taken from the response file and will modify the CONFIG SYS file in the D directory Note For info...

Страница 79: ...Capacity Manager Remote Workstation Control and Netfinity Manager World Wide Web enhancement The second section contains the names of the CD that this installation script will use The third section co...

Страница 80: ...he installation To add a line item in a specific section add all the necessary item information in the format shown in the following example Before Screen Capture GUI NULL Manager CL 1 SAVEG EXE CL 1...

Страница 81: ...Section 3 Appendixes Copyright IBM Corp 1999 71...

Страница 82: ...72 Netfinity 4000R User s Handbook...

Страница 83: ...cal support representative have the following information available 1 Server name and description 2 Proof of purchase 3 Server model serial number and manual the model and serial number are on the sma...

Страница 84: ...Computing http www ibm com pc support IBM Personal Computing Support http www ibm com pc us ibmpc IBM Commercial Desktop PCs U S http www ibm com pc us intellistation IBM IntelliStation Workstations U...

Страница 85: ...m http www apcc com http www norton com Help is also available from bulletin boards and online services as well as by fax and telephone This section provides information about these sources Services a...

Страница 86: ...76 Netfinity 4000R User s Handbook...

Страница 87: ...d Serial number Record and retain the following information The model and type M T numbers and the serial number S N for your server are located on a label on the lower right front of the server see t...

Страница 88: ...78 Netfinity 4000R User s Handbook...

Страница 89: ...lly equivalent you may return it to your place of purchase and your money will be refunded The replacement may not be new but will be in good working order Extent of Warranty The warranty does not cov...

Страница 90: ...used parts In some cases the Machine may not be new and may have been previously installed Regardless of the Machine s production status IBM s appropriate warranty terms apply Limitation of Liability...

Страница 91: ...n IBM Machine in Austria Belgium Denmark Estonia Finland France Germany Greece Iceland Ireland Italy Latvia Lithuania Luxembourg Netherlands Norway Portugal Spain Sweden Switzerland or United Kingdom...

Страница 92: ...ty and your sole remedy whether in contract or in tort in respect of any default shall be limited to damages ITALY Limitation of Liability The following replaces the second sentence in the first parag...

Страница 93: ...amages NORTH AMERICA CANADA Warranty Service The following is added to this Section To obtain warranty service from IBM call 1 800 565 3344 UNITED STATES OF AMERICA Warranty Service The following is a...

Страница 94: ...processing providing and or receiving date data within and between the 20th and 21st centuries provided all other products for example software hardware and firmware used with the product properly ex...

Страница 95: ...trademarks of Intel Corporation Microsoft MS DOS Windows and Windows NT are trademarks or registered trademarks of Microsoft Corporation Other company product and service names may be trademarks or se...

Страница 96: ...io or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment Unauthorized changes or modifications could voi...

Страница 97: ...intended to be operated at 115 volts Use a UL listed and CSA certified cord set consisting of a minimum 18 AWG Type SVT or SJT three conductor cord a maximum of 15 feet in length and a parallel blade...

Страница 98: ...88 Netfinity 4000R User s Handbook...

Страница 99: ...DB2 database support 45 delaying Netfinity Manager startup on OS 2 systems 64 description 11 detect power on error 60 device drivers 25 26 27 directories 51 DMI Browser 60 drivers network 42 dual inli...

Страница 100: ...formats 45 system requirements 45 system requirements Lotus Notes 50 system requirements ODBC 52 Netfinity Manager installation options automated 67 automated installation 67 CID installation 67 custo...

Страница 101: ...Inventory 62 specifications 8 starting Netfinity Manager 57 starting the Netfinity Manager installation program 39 symmetric multiprocessing SMP 5 system specifications 8 System Information Tool 63 sy...

Страница 102: ...IBM Part Number 00N9106 Printed in U S A N91 6...

Отзывы: