The following default response is displayed:
SLDIAG: No log messages are present.
6.
Run the sensor-related environmental tests for the RTC battery by entering the
following command from the Maintenance mode prompt:
sldiag device run -dev env
Note:
See the
IBM System Storage N series System-Level Diagnostics Guide
for a
description of the types of tests you can run.
7.
View the status of the test by entering the following command:
sldiag device
status
Your storage system provides the following output while the tests are
still running:
There are still test(s) being processed.
After all the tests are complete, the following response appears by default:
*> <SLDIAG:_ALL_TESTS_COMPLETED>
8.
Verify that no hardware problems resulted from the addition or replacement of
hardware components on your system by entering the following command:
sldiag device status [-dev
devtype
] [-name
device
] -long -state failed
System-level diagnostics returns you to the prompt if there are no test failures,
or lists the full status of failures resulting from testing the component.
9.
Proceed based on the result of the preceding step.
If the system-level diagnostics tests...
Then...
Were completed without any failures
1.
Clear the status logs by entering the
following command:
sldiag device clearstatus
2.
Verify that the log is cleared by entering
the following command:
sldiag device status
The following default response is
displayed:
SLDIAG: No log messages are present.
3.
Exit Maintenance mode by entering the
following command:
halt
4.
Enter the following command at the
firmware prompt to reboot the storage
system:
boot
5.
If your system is in an HA pair , run the
cf giveback
command (Data ONTAP
7-Mode) or the
storage failover
giveback
command (Clustered Data
ONTAP) from the partner node console.
You have completed system-level
diagnostics.
100
IBM System Storage: N6200 Series Hardware and Service Guide
Содержание N6270
Страница 12: ...xii IBM System Storage N6200 Series Hardware and Service Guide...
Страница 16: ...xvi IBM System Storage N6200 Series Hardware and Service Guide...
Страница 18: ...xviii IBM System Storage N6200 Series Hardware and Service Guide...
Страница 20: ...xx IBM System Storage N6200 Series Hardware and Service Guide...
Страница 46: ...20 IBM System Storage N6200 Series Hardware and Service Guide...
Страница 130: ...104 IBM System Storage N6200 Series Hardware and Service Guide...
Страница 134: ...108 IBM System Storage N6200 Series Hardware and Service Guide...
Страница 146: ...120 IBM System Storage N6200 Series Hardware and Service Guide...
Страница 147: ......
Страница 148: ...Printed in USA GA32 0838 04...