Quick Start Description

This Quick Start contains information you need to install and configure the router
quickly. For complete installation instructions, see the 

IBM Ethernet Router J02M

Hardware Guide

 at 

http://www.elink.ibmlink.ibm.com/publications/servlet/pbi.wss

.

A

TTENTION

:

This Quick Start contains a summary of safety warnings in 

Safety

Warnings” on page 22. For a complete list of warnings for this router, including
translations, see the 

IBM Ethernet Router J02M Hardware Guide

 at

http://www.elink.ibmlink.ibm.com/publications/servlet/pbi.wss

.

The J02M Services Router is an Ethernet-optimized edge router that provides both
switching and carrier-class Ethernet routing. The IBM Ethernet Router J02M has a
capacity of up to 120 gigabits per second (Gbps), full duplex. The IBM Ethernet Router
J02M enables a wide range of business and residential applications and services,
including high-speed transport and VPN services, next-generation broadband multiplay
services, and high-volume Internet data center internetworking.

The IBM Ethernet Router J02M is five rack units (U) tall. Several routers can be stacked
in a single floor-to-ceiling open rack, for increased port density per unit of floor space.
The router provides two dedicated slots for either two Dense Port Concentrators
(DPCs) or one Flexible PIC Concentrator (FPC). An FPC supports up to two Physical
Interface Cards (PICs). The router also provides one dedicated slot for a Switch Control
Board (SCB), and one multifunction slot for either one DPC or one SCB. Optionally,
an FPC can be installed in both the multifunction slot and lowest dedicated DPC slot.

For a list of the supported DPCs, see the 

IBM j-type m-series Ethernet Routers DPC

Guide

. For a list of the supported PICs, see the 

IBM j-type m-series Ethernet Routers

PIC Guide

.

The J02M chassis provides redundancy and resiliency. The hardware system is fully
redundant, including power supplies, Routing Engines, and SCBs.

The router is shipped in a cardboard box strapped securely to a wooden pallet. Plastic
straps secure the top and bottom in place. The router chassis is bolted to this pallet.
Quick Start installation instructions and a cardboard accessory box are also included
in the shipping container.

Quick Start Description

5

Quick Start Description

Содержание J02M

Страница 1: ...IBM Ethernet Router J02M Quick Start GA32 0656 00 ...

Страница 2: ...ESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some states or regions do not allow disclaimer of express or implied warranties in certain transactions therefore this statement may not apply to you Order publications through your IBM representative or the IBM branch office serving your locality Copyright International Busine...

Страница 3: ... Router 10 Remove Components 10 Install the Router Using a Lift 12 Install the Router Without a Mechanical Lift 13 Reinstall Components 14 Step 4 Connect External Devices and DPC or PIC Cables 14 Connect to a Network for Out of Band Management 15 Connect a Management Console 15 Connect the DPC or PIC Cables 15 Step 5 Connect Ground and Power Cables 16 Connect the Grounding Cable 16 Connect Power t...

Страница 4: ...ogo and ibm com are trademarks or registered trademarks of International Business Machines Corporation in the United States other countries or both A complete and current list of other IBM trademarks is available on the web at http www ibm com legal copytrade shtml Juniper Networks the Juniper Networks logo NetScreen and ScreenOS are registered trademarks of Juniper Networks Inc in the United Stat...

Страница 5: ...nt with local law INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some states do not allow disclaimer of express or implied warranties in certain transactions therefore this statement may not a...

Страница 6: ...oncerning non IBM products was obtained from the suppliers of those products their published announcements or other publicly available sources IBM has not tested those products and cannot confirm the accuracy of performance compatibility or any other claims related to non IBM products Questions on the capabilities of non IBM products should be addressed to the suppliers of those products If you ar...

Страница 7: ...thernet Router J02M is five rack units U tall Several routers can be stacked in a single floor to ceiling open rack for increased port density per unit of floor space The router provides two dedicated slots for either two Dense Port Concentrators DPCs or one Flexible PIC Concentrator FPC An FPC supports up to two Physical Interface Cards PICs The router also provides one dedicated slot for a Switc...

Страница 8: ... To lift routing devices and components use the following lifting guidelines Up to 39 7 lbs 18 kg 1 person lift 39 7 lbs 18 kg to 70 5 lbs 32 kg 2 or more person lift 70 5 lbs 32 kg to 121 2 lbs 55 kg 3 or more person lift Above 121 2 lbs 55 kg material handling systems such as levers slings lifts and so on must be used When this is not practical specially trained persons or systems must be used r...

Страница 9: ...n 61 cm behind the router The rack or cabinet must have an adequate supply of cooling air Ensure that the cabinet allows the chassis hot exhaust air to exit from the cabinet without recirculating into the router The router must be installed into a rack that is secured to the building structure The router should be mounted at the bottom of the rack if it is the only unit in the rack When mounting t...

Страница 10: ...page 8 3 Install the mounting shelf on the back of the rack rails Rest the bottom slot of each flange on a mounting screw 4 Partially insert screws into the open holes in each flange of the mounting shelf see Figure 2 on page 9 or Figure 3 on page 10 5 Tighten all the screws completely Table 1 J02M Mounting Hole Locations Mounting Shelf Distance Above U Division Hole X 1 14 U 2 00 in 5 1 cm 4 X 0 ...

Страница 11: ...nting Hardware for a Four Post Open Rack or Open Cabinet Step 2 Install the Mounting Hardware in a Four Post Open Rack or Open Cabinet 9 Step 2 Install the Mounting Hardware in a Four Post Open Rack or Open Cabinet ...

Страница 12: ...e router We also recommend that you install the router using a mechanical lift Remove Components on page 10 Install the Router Using a Lift on page 12 Install the Router Without a Mechanical Lift on page 13 Reinstall Components on page 14 Remove Components Figure 4 Front of the IBM Ethernet Router J02M 10 Step 3 Install the Router IBM Ethernet Router J02M Quick Start ...

Страница 13: ...e it To remove the components from the router 1 Slide each component out of the chassis evenly so that it does not become stuck or damaged 2 Label each component as you remove it so you can reinstall it in the correct location 3 Immediately store each removed component in an electrostatic bag 4 Do not stack removed components Lay each one on a flat surface NOTE For complete instructions about remo...

Страница 14: ...Router J02M onto the Lift OK MASTER FAN ONLINE OFFLINE 0 0 1 0 2 2 1 0 1 1 PEM FAIL FAIL FAIL FAIL ESD OK OK OK ACO LT YELLOW ALARM RED ALARM NC NO C NC NO C REO RE1 0 1 2 3 SCB SCB g004340 3 Using the lift position the router in front of the rack or cabinet centering it in front of the mounting shelf 4 Lift the chassis approximately 0 75 in above the surface of the mounting shelf and position it ...

Страница 15: ...ely 65 5 lb 29 5 kg and mount it in a rack To install the router without using a lift 1 Ensure that the rack is in its permanent location and is secured to the building 2 Position the router in front of the rack or cabinet centering it in front of the mounting shelf Use a pallet jack if one is available 3 With one person or two people on each side hold onto the bottom of the chassis and carefully ...

Страница 16: ...venly so that it does not become stuck or damaged 2 Tighten the captive screws for each component NOTE Make sure that all empty slots are covered with a blank panel before operating the router Step 4 Connect External Devices and DPC or PIC Cables To connect external devices and DPC or PIC cables Connect to a Network for Out of Band Management on page 15 Connect a Management Console on page 15 Conn...

Страница 17: ...m series Ethernet Routers PIC Guide 2 If the cable connector port is covered by a rubber safety plug remove the plug DANGER Do not look directly into a fiber optic transceiver or into the ends of fiber optic cables Fiber optic transceivers and fiber optic cable connected to a transceiver emit laser light that can damage your eyes CAUTION Do not leave a fiber optic transceiver uncovered except when...

Страница 18: ...ither AC or DC power supplies Perform the appropriate procedures for each power supply in your router CAUTION You must ground the router before connecting either the AC power cord or the DC power cables Connect the Grounding Cable on page 16 Connect Power to an AC Router on page 17 Connect Power to a DC Router on page 18 Connect the Grounding Cable 1 Attach an electrostatic discharge ESD grounding...

Страница 19: ...e power cords shipped with the router which should have a plug appropriate for your geographical location See the IBM Ethernet Router J02M Hardware Guide 3 Move the circuit breaker on the power supply faceplate to the off position O 4 Insert the appliance coupler end of the power cord into the appliance inlet on the power supply 5 Insert the power cord plug into an external AC power source recepta...

Страница 20: ...xternal DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply 1 Ensure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cable leads might become active during installation 2 Attach an electrostatic discharge ESD grounding strap to your bare wrist and connec...

Страница 21: ...nal studs on the DC power supply is 36 lb in 4 0 Nm The terminal studs may be damaged if excessive torque is applied Use only a torque controlled driver or socket wrench to tighten nuts on the DC power supply terminal studs 6 Replace the clear plastic cover over the terminal studs on the faceplate 7 Repeat Step 3 through Step 6 for the remaining power supplies 8 Attach an electrostatic discharge E...

Страница 22: ... of the router If the name includes spaces enclose the name in quotation marks edit root set system host name host name 6 Configure the router s domain name edit root set system domain name domain name 7 Configure the IP address and prefix length for the router s Ethernet interface edit root set interfaces fxp0 unit 0 family inet address address prefix length 8 Configure the IP address of a backup...

Страница 23: ... host name domain name domain name backup router address root authentication authentication method password public key name server address interfaces fxp0 unit 0 family inet address address prefix length 12 Commit the configuration to activate it on the router edit root commit 13 Optionally configure additional properties by adding the necessary configuration statements Then commit the changes to ...

Страница 24: ...f the strap around your bare wrist Failure to use an ESD strap could result in damage to the router CAUTION Use an external surge protective device SPD at the AC input of the router Only trained and qualified personnel should install or replace the router If you need additional assistance installing the router contact your IBM representative Perform only the procedures described in this quick star...

Страница 25: ...mponent side up on a flat antistatic surface or in an electrostatic bag When you install the router always make the ground connection first and disconnect it last Wire the DC power supply using the appropriate lugs When connecting power the proper wiring sequence is ground to ground RTN to RTN then 48 V to 48 V When disconnecting power the proper wiring sequence is 48 V to 48 V RTN to RTN then gro...

Страница 26: ...fee you can get telephone assistance with usage configuration and software problems For information about which products are supported by Support Line in your country or region go to the following Web site www ibm com services sl products For more information about the IBM Support Line and other IBM services go to the following Web sites www ibm com services www ibm com planetwide 24 Hardware Serv...

Страница 27: ... device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Industry Canada Class A Emission Compliance Statement This Class A digital apparatus complies with Canadian ICES 003 Avis de conformité à...

Страница 28: ...e Empfehlung der IBM gesteckt eingebaut werden EN 55022 Klasse A Geräte müssen mit folgendem Warnhinweis versehen werden Warnung Dieses ist eine Einrichtung der Klasse A Diese Einrichtung kann im Wohnbereich Funk Störungen verursachen in diesem Fall kann vom Betreiber verlangt werden angemessene Maßnahmen zu ergreifen und dafür aufzukommen Deutschland Einhaltung des Gesetzes über die elektromagnet...

Страница 29: ...apan VCCI Class A ITE Electronic Emission Statement Korea Class A Electronic Emission Statement Taiwan Contact Information IBM Taiwan Product Service Contact Info IBM Taiwan Corporation 3F No 7 Song Ren Rd Taipei Taiwan Tel 0800 016 888 Electronic emission notices 27 ...

Страница 30: ...suggestions for improving this document send us your comments by e mail to starpubs us ibm com Be sure to include the following v Exact publication title v Publication form number for example GC26 1234 02 v Page table or illustration numbers v A detailed description of any information that should be changed 28 IBM Ethernet Router J02M Quick Start ...

Страница 31: ......

Страница 32: ... Part Number 45W5526 Printed in USA GA32 0656 00 1P P N 45W5526 530 031077 Rev 2 ...

Отзывы: