4.
Make sure that grounding surfaces are clean and brought to a bright finish before
grounding connections are made.
5.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and
connect the strap to one of the ESD points on the chassis. For more information
about ESD, see the
IBM Ethernet Router J02M Hardware Guide
6.
Place the grounding cable lug over the grounding point on the top rear of the
chassis. The grounding point is sized for UNC 1/4-20 bolts.
7.
Secure the grounding cable lug to the grounding points, first with the washers,
then with the screws.
8.
Verify that the grounding cabling is correct, that the grounding cable does not
touch or block access to router components, and that it does not drape where
people could trip on it.
Connect Power to an AC Router
CAUTION
:
The router must be properly grounded before you connect the AC power
cords.
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and
connect the strap to one of the ESD points on the chassis. For more information
about ESD, see the
IBM Ethernet Router J02M Hardware Guide
2.
Locate the power cords shipped with the router, which should have a plug
appropriate for your geographical location. See the
IBM Ethernet Router J02M
Hardware Guide
.
3.
Move the circuit breaker on the power supply faceplate to the off position (
O
).
4.
Insert the appliance coupler end of the power cord into the appliance inlet on
the power supply.
5.
Insert the power cord plug into an external AC power source receptacle.
NOTE:
Each power supply must be connected to a dedicated AC power feed and a
dedicated customer site circuit breaker. We recommend that you use a minimum,
or as permitted by local code.
6.
Dress the power cord appropriately. Verify that the power cord does not block
the air exhaust and access to router components, or drape where people could
trip on it.
7.
Repeat Step 2 through Step 6 for the remaining power supplies.
8.
Switch the AC switch on each power supply to the on position (
—
) and observe
the status LEDs on each power supply faceplate. If an AC power supply is correctly
installed and functioning normally, the
AC OK
and
DC OK
LEDs light steadily, and
the
PS FAIL
LED is not lit.
If any of the status LEDs indicates that the power supply is not functioning
normally, repeat the installation and cabling procedures.