11.16.3 SCSI Bus Reset and TARGET RESET Message
These two reset conditions cause the following to be performed.
!
If reset goes active while the power-up sequence is in progress, the power-up sequence is started
over.
!
If the Auto Spin up is enabled and the bring-up operation has not been completed, the bring-up
operation will be re-attempted from the beginning.
Note: The bring-up operation, having already completed, is not rerun.
!
If reset occurs while a physical sector is being written, the write operation is disabled after the current
physical sector is written. Data is not lost as long as power stays valid until the physical sector being
written is completed.
11.16.4 Self-initiated Reset
When the microcode detects an internal logic error, it takes a special bring-up sequence to save the infor-
mation necessary to analyze the error. After saving the information, the normal bring-up sequence is taken
to start over.
.
Ultrastar 146Z10 hard disk drive specifications
211
Содержание IC35L036UWDY10 - Ultrastar 36.7 GB Hard...
Страница 2: ...This page intentionally left blank ...
Страница 16: ...Ultrastar 146Z10 hard disk drive specifications xiv ...
Страница 20: ...This page intentionally left blank ...
Страница 21: ...Part 1 Functional specification Ultrastar 146Z10 hard disk drive specifications 5 ...
Страница 22: ...This page intentionally left blank ...
Страница 24: ...This page intentionally left blank ...
Страница 34: ...This page intentionally left blank ...
Страница 36: ...This page intentionally left blank ...
Страница 63: ...Part 2 Interface specification Ultrastar 146Z10 hard disk drive specifications 47 ...
Страница 64: ...This page intentionally left blank ...