8.14 PRE-FETCH (34h)
LINK
FLAG
Reserved = 0
VU = 0
9
(MSB)
Transfer Length
(LSB)
7
8
Reserved = 0
6
(MSB)
Logical Block Address
(LSB)
2
3
4
5
RelAdr
= 0
Immed
= 0
Reserved = 0
Reserved = 0
1
Command Code = 34h
0
0
1
2
3
4
5
6
7
Bit
Byte
Figure 120. Pre-Fetch
The PRE-FETCH command requests the drive to transfer data to the cache. No data is transferred to the
initiator.
!
Transfer length specifies the number of contiguous blocks of data that are to be transferred into the
cache. A transfer length of zero indicates that blocks are to be transferred into the cache until the
segment is filled or until here are no more blocks on the media.
!
Immed (Immediate) must be zero. An immediate bit of zero indicates that the status shall not be
returned until the operation has completed. If the Immed bit is set to one, the drive returns a CHECK
CONDITION status. The sense key shall be set to ILLEGAL REQUEST and the additional sense code
shall be set to INVALID FIELD in CDB.
!
RelAdr (Relative Block Address) is not supported and must be set to zero.
Ultrastar 146Z10 hard disk drive specifications
126
Содержание IC35L018UCDY10
Страница 2: ...This page intentionally left blank ...
Страница 16: ...Ultrastar 146Z10 hard disk drive specifications xiv ...
Страница 20: ...This page intentionally left blank ...
Страница 21: ...Part 1 Functional specification Ultrastar 146Z10 hard disk drive specifications 5 ...
Страница 22: ...This page intentionally left blank ...
Страница 24: ...This page intentionally left blank ...
Страница 34: ...This page intentionally left blank ...
Страница 36: ...This page intentionally left blank ...
Страница 63: ...Part 2 Interface specification Ultrastar 146Z10 hard disk drive specifications 47 ...
Страница 64: ...This page intentionally left blank ...