8.8.12 Mode Page 1A (Power Control Parameters)
(MSB)
Standby Condition Timer
(LSB)
8
|
11
(MSB)
Idle Condition Timer
(LSB)
4
|
7
Standby
[Idle]
Reserved
3
Reserved
2
Page Length = 0Ah
1
Page Code = 1Ah
RSVD
RSVD
0
0
1
2
3
4
5
6
7
Bit
Byte
Figure 102. Page 1A (Power Control)
!
Idle and Idle Condition Timer are ignored.
!
Standby of one indicates that the drive uses Standby Condition Timer to determine the length of
inactivity time to wait before unloading the actuator. Spindle motor is not stopped. Next media access
command load the actuator. Idle time function does not load the actuator. A Standby of zero indicates
that the drive does not unload the actuator.
!
Standby Condition Timer specifies the inactivity time in increments of 100 ms. The minimum allow-
able inactivity time is 60 minutes. Any value less than this is accepted, but will automatically default to
60 minutes.
Ultrastar 146Z10 hard disk drive specifications
110
Содержание IC35L018UCDY10
Страница 2: ...This page intentionally left blank ...
Страница 16: ...Ultrastar 146Z10 hard disk drive specifications xiv ...
Страница 20: ...This page intentionally left blank ...
Страница 21: ...Part 1 Functional specification Ultrastar 146Z10 hard disk drive specifications 5 ...
Страница 22: ...This page intentionally left blank ...
Страница 24: ...This page intentionally left blank ...
Страница 34: ...This page intentionally left blank ...
Страница 36: ...This page intentionally left blank ...
Страница 63: ...Part 2 Interface specification Ultrastar 146Z10 hard disk drive specifications 47 ...
Страница 64: ...This page intentionally left blank ...