![IBM Flex System FC3171 Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/ibm/flex-system-fc3171/flex-system-fc3171_installation-and-user-manual_3464825040.webp)
30
IBM Flex System FC3171 8 Gb SAN Switch and Pass-thru Installation and User’s Guide
5. Normally, the date and time are set by the CMM through NTP. However, as an
option, you can set the date and time of the switch by typing
date
[MMDDhhmmCCYY]
where:
[MM]
is the month
[DD]
is the day
[hh]
is the hour in 24-hour format
[mm]
is the minute
[CC]
represents the century identifier
[YY]
represents the last two numbers of the year
For example, the format for November 28 2011 8:46 p.m. is date 112820462011.
Press Enter.
6. Type
admin end
and press Enter to exit from the administrator operating mode
and return to the standard operating mode.
Note:
For more information about password requirements and using the CLI, see
the applicable documentation that is listed in “CLI command format” on page 30.
CLI command format
The information in this section is an overview of the CLI command format. For
detailed information about using CLI commands, see the applicable documentation
at http://publib.boulder.ibm.com/infocenter/flexsys/information/index.jsp.
•
IBM Flex System Chassis Management Module Command-Line Interface Reference
Guide
•
IBM Flex System FC3171 8 Gb SAN Switch Command Line Interface User’s Guide
•
IBM Flex System FC3171 8 Gb Pass-thru Command Line Interface User’s Guide
A command is followed by one or more keywords. The following rules apply when
you type keywords:
•
Commands and keywords are lowercase and case sensitive.
•
Required keyword values are shown in standard font: [value]. Optional values
are shown in italics
[value]
.
•
The underlined portion of each keyword indicates the abbreviated form that can
be used. For example, the Delete keyword can be abbreviated as Del.
The CLI command syntax is as follows:
•
keyword
•
keyword
[value]
•
keyword
[value 1][value 2]
You can change items in brackets ([ ]) by typing a new value. You can use the
Backspace and Delete keys to erase characters behind and in front of the cursor.
Содержание Flex System FC3171
Страница 1: ...IBM Flex System FC3171 8 Gb SAN Switch and Pass thru Installation and User s Guide...
Страница 2: ......
Страница 3: ...IBM Flex System FC3171 8 Gb SAN Switch and Pass thru Installation and User s Guide...
Страница 7: ...Copyright IBM Corp 2012 vii Safety...
Страница 8: ...viii IBM Flex System FC3171 8 Gb SAN Switch and Pass thru Installation and User s Guide...
Страница 9: ...Safety ix...
Страница 22: ...12 IBM Flex System FC3171 8 Gb SAN Switch and Pass thru Installation and User s Guide...
Страница 28: ...18 IBM Flex System FC3171 8 Gb SAN Switch and Pass thru Installation and User s Guide...
Страница 44: ...34 IBM Flex System FC3171 8 Gb SAN Switch and Pass thru Installation and User s Guide...
Страница 46: ...36 IBM Flex System FC3171 8 Gb SAN Switch and Pass thru Installation and User s Guide...
Страница 53: ...Copyright IBM Corp 2012 43 Appendix B Notices...
Страница 56: ...46 IBM Flex System FC3171 8 Gb SAN Switch and Pass thru Installation and User s Guide...
Страница 57: ...Appendix B Notices 47...
Страница 62: ...52 IBM Flex System FC3171 8 Gb SAN Switch and Pass thru Installation and User s Guide...
Страница 63: ......
Страница 64: ...1P P N 88Y7928 88Y7928 Part Number 88Y7928 Printed in USA...