Chapter 3. Information panel LEDs and external Fibre Channel ports
23
Ethernet port LEDs
There are two LEDs built into the Ethernet port that indicate the transmission
activity over the Ethernet connection and link status.
Table 6 contains a description of Ethernet port LEDs.
LED activities and diagnostic flash patterns
Table 7 contains descriptions of the activities and corresponding diagnostic flash
patterns for the switch LEDs.
Table 6. Ethernet port LEDs
LED name
LED description
Activity LED
The Activity LED is lit when data is transmitted or received over
the Ethernet connection.
Link Status LED
The Link Status LED is lit when an Ethernet connection is estab-
lished.
Table 7. Switch LED activities and diagnostic flash patterns
LED name
LED activity/diagnostic flash pattern
OK
This LED is lit at startup and remains lit while the switch is pow-
ered on.
Location
This LED is lit when enabled by the Chassis Management Mod-
ule web interface or command line interface.
! (Switch Fault)
This LED operates as follows:
• The LED is off during initialization or when the switch is in
normal operation.
• The LED is lit during LED test or to indicate a system fault
during a POST failure, thermal fault, or other critical switch
fault.
External port
Logged-in (LOG)
This LED operates as follows:
• The LED is off when the corresponding external port is not
logged in.
• The LED is lit when the corresponding external port is logged
in or during the LED test.
• The LED pattern indicates the following conditions:
— Logged in: The LED is lit.
— Logging in: The LED flashes at 1-second intervals.
— Beacon location: The LED flashes at 1-second intervals.
— Error: The LED flashes two times per second.
— The corresponding external port is disabled: The LED
flashes at 1-second intervals.
Содержание Flex System FC3171
Страница 1: ...IBM Flex System FC3171 8 Gb SAN Switch and Pass thru Installation and User s Guide...
Страница 2: ......
Страница 3: ...IBM Flex System FC3171 8 Gb SAN Switch and Pass thru Installation and User s Guide...
Страница 7: ...Copyright IBM Corp 2012 vii Safety...
Страница 8: ...viii IBM Flex System FC3171 8 Gb SAN Switch and Pass thru Installation and User s Guide...
Страница 9: ...Safety ix...
Страница 22: ...12 IBM Flex System FC3171 8 Gb SAN Switch and Pass thru Installation and User s Guide...
Страница 28: ...18 IBM Flex System FC3171 8 Gb SAN Switch and Pass thru Installation and User s Guide...
Страница 44: ...34 IBM Flex System FC3171 8 Gb SAN Switch and Pass thru Installation and User s Guide...
Страница 46: ...36 IBM Flex System FC3171 8 Gb SAN Switch and Pass thru Installation and User s Guide...
Страница 53: ...Copyright IBM Corp 2012 43 Appendix B Notices...
Страница 56: ...46 IBM Flex System FC3171 8 Gb SAN Switch and Pass thru Installation and User s Guide...
Страница 57: ...Appendix B Notices 47...
Страница 62: ...52 IBM Flex System FC3171 8 Gb SAN Switch and Pass thru Installation and User s Guide...
Страница 63: ......
Страница 64: ...1P P N 88Y7928 88Y7928 Part Number 88Y7928 Printed in USA...