MAP
1020:
Problem
Determination
Purpose
of
This
MAP
Use
this
MAP
to
get
an
error
code
if
you
were
not
provided
one
by
the
customer
or
you
are
unable
to
load
diagnostics.
If
you
are
able
to
load
the
diagnostics,
go
to
MAP
0020
in
the
RS/6000
and
Eserver
pSeries
Diagnostic
Information
for
Multiple
Bus
Systems
.
The
service
processor
may
have
recorded
one
or
more
symptoms
in
its
error
log.
Examine
this
error
log
before
proceeding
(see
The
server
may
have
been
set
up
by
using
the
HMC.
Check
the
Service
Action
Event
(SAE)
log
in
the
Service
Focal
Point.
The
SAE
log
may
have
recorded
one
or
more
symptoms
in
the
Service
Focal
Point.
To
avoid
unnecessary
replacement
of
the
same
FRU
for
the
same
problem,
it
is
necessary
to
check
the
SAE
log
for
evidence
of
prior
service
activity
on
the
same
subsystem.
If
you
find
any
error
codes
in
the
service
processor
error
log
or
the
Service
Focal
Point,
record
all
error
codes
and
any
location
codes
in
the
order
you
find
them
and
process
each
error
code
and
location
code
beginning
at
the
Entry
MAP.
Otherwise,
continue
with
the
directions
for
MAP
1020.
The
service
processor
may
have
been
set
by
the
user
to
monitor
system
operations
and
to
attempt
recoveries.
You
can
disable
these
actions
while
you
diagnose
and
service
the
system.
If
the
system
was
set
up
according
to
the
recommendations
of
the
Eserver
pSeries
690
User’s
Guide
,
all
the
settings
of
the
service
processor
(except
language)
were
saved
by
using
the
SAVE/RESTORE
HARDWARE
MAINTENANCE
POLICIES
service
aid.
You
can
use
the
same
service
aid
to
restore
the
settings
at
the
conclusion
of
your
service
action.
In
case
the
service
processor
settings
were
not
saved
by
the
user,
if
you
disable
them,
make
notes
of
their
current
settings
for
restoration
before
you
leave.
In
addition
to
the
parameters
in
the
following
table,
you
can
disconnect
the
modem
to
prevent
incoming
signals
that
could
cause
the
system
to
power
on.
Following
are
the
service
processor
settings.
The
service
processor
menus
are
described
in
Surveillance
From
the
service
processor
Setup
Menu,
go
to
the
Surveillance
Setup
Menu
and
disable
surveillance.
(Surveillance
is
automatically
disabled
in
LPAR
mode.)
Unattended
Start
From
the
service
processor
System
Power
Control
Menu,
disable
unattended
start
mode.
Reboot
Policy
From
the
System
Power
Control
Menu,
go
to
the
Reboot/Restart
Policy
Setup
Menu
and
set:
1.
Number
of
reboot
attempts
to
0
(zero)
2.
Use
OS-Defined
restart
policy
to
No
3.
Enable
supplemental
restart
policy
to
No
.
Call
Out
From
the
Call-In/Call-Out
Setup
Menu,
go
to
the
Serial
Port
Selection
Menu
and
disable
call-out
on
both
serial
ports.
(Call-out
is
automatically
disabled
when
the
system
is
booted
to
operate
with
multiple
partitions
(also
known
as
a
partitioned
system
).
Be
prepared
to
record
code
numbers
and
use
those
numbers
in
the
course
of
analyzing
a
problem.
Go
to
160
Eserver
pSeries
690
Service
Guide
Содержание eserver pSeries 690
Страница 1: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Страница 2: ......
Страница 3: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Страница 12: ...x Eserver pSeries 690 Service Guide...
Страница 14: ...xii Eserver pSeries 690 Service Guide...
Страница 228: ...Step 1527 5 Call your next level of support 212 Eserver pSeries 690 Service Guide...
Страница 357: ...Step 1543 15 Call for support This ends the procedure Chapter 3 Maintenance Analysis Procedures 341...
Страница 362: ...Step 1545 15 Call for support This ends the procedure 346 Eserver pSeries 690 Service Guide...
Страница 365: ...Step 1546 15 Call for support This ends the procedure Chapter 3 Maintenance Analysis Procedures 349...
Страница 381: ...Step 154A 14 Turn off the power Chapter 3 Maintenance Analysis Procedures 365...
Страница 430: ...414 Eserver pSeries 690 Service Guide...
Страница 798: ...782 Eserver pSeries 690 Service Guide...
Страница 868: ...Media Subsystem Internal Cables 1021 p690 Cable Installation and Management 1022 852 Eserver pSeries 690 Service Guide...
Страница 910: ...MCM Installation Shorts Test Step 3 See L3 Cache Modules on page 898 894 Eserver pSeries 690 Service Guide...
Страница 923: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 907...
Страница 924: ...L3 Cache Shorts Test Step 5 908 Eserver pSeries 690 Service Guide...
Страница 926: ...L3 Cache Shorts Test Step 2 910 Eserver pSeries 690 Service Guide...
Страница 928: ...L3 Cache Shorts Test Step 4 912 Eserver pSeries 690 Service Guide...
Страница 929: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 913...
Страница 1055: ...7040 Model 681 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 1039...
Страница 1057: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 1041...
Страница 1061: ...Power Cabling Chapter 10 Parts Information 1045...
Страница 1090: ...1074 Eserver pSeries 690 Service Guide...
Страница 1094: ...1078 Eserver pSeries 690 Service Guide...
Страница 1109: ...error Handle unexpected modem responses expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix D Modem Configurations 1093...
Страница 1122: ...1106 Eserver pSeries 690 Service Guide...
Страница 1123: ...Appendix E Ground Path The ground path for the pSeries 690 is shown in the following figure 1107...
Страница 1124: ...1108 Eserver pSeries 690 Service Guide...
Страница 1132: ...1116 Eserver pSeries 690 Service Guide...
Страница 1133: ......
Страница 1134: ...Printed in U S A February 2004 SA38 0589 05...