Step 6. Placing the 7210 DVD-RAM Drive

The 7210 DVD-RAM Drive can be located anywhere that is convenient to your
system unit. The only restrictions are the length of the power cord and the SCSI
cable. Recommended locations are:

v

Away from the floor

v

In a horizontal position

v

Where the DVD disc can be easily inserted

To place the 7210 DVD-RAM Drive, do the following:

1.

__ Set the 7210 DVD-RAM Drive in the location that you have previously
determined.

2.

__ Connect the power cable to the 7210 DVD-RAM Drive. (Do not plug it
into the electrical outlet at this time.)

The external devices that attach to the system unit can be stacked. The 7210
DVD-RAM Drive should be placed at the top of the stack.

Step 7. Performing a System Shutdown

Attention:

Do not attach the 7210 DVD-RAM Drive to an active system unit. This

can damage the 7210 DVD-RAM Drive, the system unit, or both.

To perform a system shutdown, do the following:

Note:

Before doing a controlled shutdown of the system unit, notify other users
who may be using the system.

1.

__ If it is on, perform a controlled shutdown of the system as follows:
For RS/6000 or pSeries Systems

: To do a fast shutdown, type

shutdown -F

from the console. (You must have root authority to do the shutdown; see your
system administrator.) Depending on the host system configuration, the
shutdown may take several minutes. When the message Halt Completed
displays on the console, continue with step 2.

For AS/400 or iSeries Systems:

For instructions about performing a controlled

shutdown, refer to the host system documentation, then return here and
continue with step 2.

2.

__ When the shutdown is complete, turn off the power to the system unit.

3.

__ Turn off the power to all external devices connected to the system unit.
DANGER

An electrical outlet that is not correctly wired could place hazardous
voltage on metal parts of the system or the products that attach to the
system. It is the customer’s responsibility to ensure that the outlet is
correctly wired and grounded to prevent an electrical shock. (RSFTD201)

4.

__ Unplug the power cables to all external devices from their electrical outlets.

5.

__ Unplug the system unit power cable from the electrical outlet.

Chapter 2. Setting Up

7

Содержание eserver 7210

Страница 1: ...7210 Model 025 External DVD RAM Drive 7210 Model 025 DVD RAM Drive Setup and Operator Guide SY44 0079 00...

Страница 2: ......

Страница 3: ...7210 Model 025 External DVD RAM Drive 7210 Model 025 DVD RAM Drive Setup and Operator Guide SY44 0079 00...

Страница 4: ...025 of the 7210 External DVD RAM Drive and to all subsequent releases and modifications until otherwise indicated in new editions This edition applies only to the specified model of the device Copyrig...

Страница 5: ...trical Outlets 4 Step 3 Assembling the Materials 4 Step 4 Determining the SCSI Address for RS 6000 or pSeries Systems Only 4 Step 5 Setting the SCSI Address 6 Step 6 Placing the 7210 DVD RAM Drive 7 S...

Страница 6: ...iv 7210 DVD RAM Drive Setup and Operator Guide...

Страница 7: ...our country or send inquiries in writing to IBM World Trade Asia Corporation Licensing 2 31 Roppongi 3 chome Minato ku Tokyo 106 0032 Japan The following paragraph does not apply to the United Kingdom...

Страница 8: ...y as possible the examples include the names of individuals companies brands and products All of these names are fictitious and any similarity to the names and addresses used by an actual business ent...

Страница 9: ...g facilities exist IBM does not currently collect and recycle used IBM products from customers in the United States other than those products that are involved in trade in programs Companies are avail...

Страница 10: ...rference by one or more of the following measures v Reorient or relocate the receiving antenna v Increase the separation between the equipment and receiver v Connect the equipment into an outlet on a...

Страница 11: ...and connectors IBM part number 75G5958 or its equivalent must be used in order to reduce the potential for causing interference to radio and TV communications and to other electrical or electronic eq...

Страница 12: ...ted States or other countries or both AIX Application System 400 AS 400 e Stylized eServer IBM iSeries Operating System 400 OS 400 pSeries RISC System 6000 RS 6000 400 Other company product and servic...

Страница 13: ...lights on the 7210 DVD RAM Drive It tells how to load and unload a DVD disc and gives information about cleaning the drive and the discs Chapter 4 Removing the 7210 DVD RAM Drive tells how to remove...

Страница 14: ...ment form from a country other than the United States you can give the form to the local IBM branch office or IBM representative for postage paid mailing v If you prefer to send comments by FAX use ei...

Страница 15: ...nly read media marked as CD R CD R W and CD ROM The 7210 DVD RAM Drive supports the distribution and use of on line databases such as an on line reference for a softcopy publication Figure 1 shows a f...

Страница 16: ...DVD RAM Drive To determine the appropriate cable refer to Chapter 4 Parts Diagram and Parts List in the 7210 Model 025 DVD RAM Drive Service Guide Specifications Table 1 Specifications for the 7210 M...

Страница 17: ...e 7210 DVD RAM Drive simply remove the packing material from the box it was shipped in Performing the Installation To install the 7210 Model 025 DVD RAM Drive complete the following steps Step 1 Using...

Страница 18: ...CSI controller is located where you make the cable connection Record the controller location here 4 3 I 0 0 0 2 Step 4 Determining the SCSI Address for RS 6000 or pSeries Systems Only Before you insta...

Страница 19: ...ue Note the address of the SCSI I O controller in this case 7 3 To identify the SCSI addresses used by all other devices type lsdev Cs scsi and then press Enter A list of devices appears in the follow...

Страница 20: ...the or push button to set the SCSI address switch to the address that you have previously determined in Step 3 Assembling the Materials on page 4 AS 400 or iSeries Systems Set the SCSI address switch...

Страница 21: ...be using the system 1 __ If it is on perform a controlled shutdown of the system as follows For RS 6000 or pSeries Systems To do a fast shutdown type shutdown F from the console You must have root aut...

Страница 22: ...y device on the SCSI bus connect the cable to the host system see Figure 4 on page 9 Connect a terminator to the unused SCSI bus cable connector v If the 7210 DVD RAM Drive is part of a multiple devic...

Страница 23: ...ic external storage devices including the 7210 DVD RAM Drive Contact your IBM authorized support personnel for information about valid attached devices and the configurations allowed by the system 3 W...

Страница 24: ...the following 1 DANGER An electrical outlet that is not correctly wired could place hazardous voltage on metal parts of the system or the products that attach to the system It is the customer s respo...

Страница 25: ...figure the 7210 DVD RAM Drive to the host system software by doing the following a Log into the host system AIX operating system Note You must have root authority to install or remove the 7210 DVD RAM...

Страница 26: ...been attached 4 __ In the Opt column type 9 next to the adapter then press Enter The Work with Storage Controller Resources screen now displays the adapter on the first row The 7210 DVD RAM Drive sho...

Страница 27: ...t is an International Organization for Standardization ISO symbol for a push button switch Load Unload Button The load unload button 3 enables the DVD RAM tray to be inserted or ejected To insert or e...

Страница 28: ...ng indicator lights Power On Light When the 7210 DVD RAM Drive is turned on the power on light 1 comes on and is green Status Light The status light 5 can be in one of several states v The light is of...

Страница 29: ...d button v Gently push the disc tray completely into the disc opening If the DVD disc fails to eject refer to the procedure for manually removing a disc in the 7210 Model 025 DVD RAM Drive Service Gui...

Страница 30: ...16 7210 DVD RAM Drive Setup and Operator Guide...

Страница 31: ...system manuals Attention Failure to inform the operating system before you add or delete a device may result in data loss or a system fault 3 __ If it is on perform a controlled shutdown of the syste...

Страница 32: ..._ Ensure that the terminator is on the last device on the SCSI bus see Step 9 Installing the SCSI Bus Terminator on page 8 CAUTION Do not remove the covers of the unit An invisible laser beam may be p...

Страница 33: ...lugs approved by the appropriate testing organization for the specific countries where they are used For units set at 230 V outside of U S Use a Cable Set consisting of a minimum 18 AWG cable and grou...

Страница 34: ...mark 5 14F0015 South Africa Bangladesh Burma Pakistan South Africa Sri Lanka 6 14F0033 United Kingdom Bahrain Bermuda Brunei Channel Islands Cyprus Ghana Hong Kong India Iraq Ireland Jordan Kenya Kuwa...

Страница 35: ...ation in this book is Very Satisfied Satisfied Neutral Dissatisfied Very Dissatisfied Accurate h h h h h Complete h h h h h Easy to find h h h h h Easy to understand h h h h h Well organized h h h h h...

Страница 36: ...lopment Department 542 3605 Hwy 52 North Rochester Minnesota 55901 7829 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Страница 37: ......

Страница 38: ...Part Number 19P3654 Printed in U S A SY44 0079 00 1P P N 19P3654...

Отзывы: