background image

1.

To identify the name and the port of a host system SCSI I/O controller to
which you want to attach the 7210 DVD-RAM Drive, at the system prompt
type

lsdev -C |grep scsi

and then press Enter. A list of controllers displays in the following format. The
names appear in the first column (for example, scsi0 and scsi2 ). The ports
appear in the third column and in the fourth position (highlighted as follows):

scsi0

Available 00-0

0

-0S

Standard SCSI I/O Controller

scsi2

Available 00-0

2

SCSI I/O Controller

Note the name and port of the SCSI I/O controller to which you want to attach the
7210 DVD-RAM Drive (for example, the scsi2 controller on port 2 ).

2.

To determine the SCSI address of the SCSI I/O controller that you noted in the
previous step, type

lsattr -El scsix |grep id

(where x equals the last character in the name of the SCSI I/O controller), then
press Enter. The address of the SCSI I/O controller displays in the following
format:

id

7

Adapter card SCSI I

True

Note the address of the SCSI I/O controller (in this case, 7 ).

3.

To identify the SCSI addresses used by all other devices, type

lsdev -Cs scsi

and then press Enter. A list of devices appears in the following format. In the
fourth position of the third column, locate all instances of the port that you
chose in step 1. (The list may contain multiple instances of a port. In the
following example, for port 2 (identified in step 1), there are three instances.)
The addresses of the other SCSI devices appear in the seventh position
(highlighted in the example that follows):

hdisk0

Available

00-00-0S-

0

,0

2.0GB SCSI DiskDrive

hdisk1

Available

00-02-01-

2

,0

4.5GB 16 Bit SCSI DiskDrive

hdisk2

Available

00-02-01-

3

,0

SCSI DiskDrive

rmt0

Available

00-02-01-

4

,0

SCSI 8mm Tape Drive

For the port chosen in step 1, note the addresses of the other SCSI devices attached
to the host system (in this case, for port 2, the addresses are 2 , 3 , and 4 ).

4.

Determine an unused SCSI address for the 7210 DVD-RAM Drive (in this case,
0, 1, 5, or 6, because 7 was used by the SCSI I/O controller and 2, 3, and 4 are
used by other devices).

Record the address here

43I

0002

Chapter 2. Setting Up

5

Содержание eserver 7210

Страница 1: ...7210 Model 025 External DVD RAM Drive 7210 Model 025 DVD RAM Drive Setup and Operator Guide SY44 0079 00...

Страница 2: ......

Страница 3: ...7210 Model 025 External DVD RAM Drive 7210 Model 025 DVD RAM Drive Setup and Operator Guide SY44 0079 00...

Страница 4: ...025 of the 7210 External DVD RAM Drive and to all subsequent releases and modifications until otherwise indicated in new editions This edition applies only to the specified model of the device Copyrig...

Страница 5: ...trical Outlets 4 Step 3 Assembling the Materials 4 Step 4 Determining the SCSI Address for RS 6000 or pSeries Systems Only 4 Step 5 Setting the SCSI Address 6 Step 6 Placing the 7210 DVD RAM Drive 7 S...

Страница 6: ...iv 7210 DVD RAM Drive Setup and Operator Guide...

Страница 7: ...our country or send inquiries in writing to IBM World Trade Asia Corporation Licensing 2 31 Roppongi 3 chome Minato ku Tokyo 106 0032 Japan The following paragraph does not apply to the United Kingdom...

Страница 8: ...y as possible the examples include the names of individuals companies brands and products All of these names are fictitious and any similarity to the names and addresses used by an actual business ent...

Страница 9: ...g facilities exist IBM does not currently collect and recycle used IBM products from customers in the United States other than those products that are involved in trade in programs Companies are avail...

Страница 10: ...rference by one or more of the following measures v Reorient or relocate the receiving antenna v Increase the separation between the equipment and receiver v Connect the equipment into an outlet on a...

Страница 11: ...and connectors IBM part number 75G5958 or its equivalent must be used in order to reduce the potential for causing interference to radio and TV communications and to other electrical or electronic eq...

Страница 12: ...ted States or other countries or both AIX Application System 400 AS 400 e Stylized eServer IBM iSeries Operating System 400 OS 400 pSeries RISC System 6000 RS 6000 400 Other company product and servic...

Страница 13: ...lights on the 7210 DVD RAM Drive It tells how to load and unload a DVD disc and gives information about cleaning the drive and the discs Chapter 4 Removing the 7210 DVD RAM Drive tells how to remove...

Страница 14: ...ment form from a country other than the United States you can give the form to the local IBM branch office or IBM representative for postage paid mailing v If you prefer to send comments by FAX use ei...

Страница 15: ...nly read media marked as CD R CD R W and CD ROM The 7210 DVD RAM Drive supports the distribution and use of on line databases such as an on line reference for a softcopy publication Figure 1 shows a f...

Страница 16: ...DVD RAM Drive To determine the appropriate cable refer to Chapter 4 Parts Diagram and Parts List in the 7210 Model 025 DVD RAM Drive Service Guide Specifications Table 1 Specifications for the 7210 M...

Страница 17: ...e 7210 DVD RAM Drive simply remove the packing material from the box it was shipped in Performing the Installation To install the 7210 Model 025 DVD RAM Drive complete the following steps Step 1 Using...

Страница 18: ...CSI controller is located where you make the cable connection Record the controller location here 4 3 I 0 0 0 2 Step 4 Determining the SCSI Address for RS 6000 or pSeries Systems Only Before you insta...

Страница 19: ...ue Note the address of the SCSI I O controller in this case 7 3 To identify the SCSI addresses used by all other devices type lsdev Cs scsi and then press Enter A list of devices appears in the follow...

Страница 20: ...the or push button to set the SCSI address switch to the address that you have previously determined in Step 3 Assembling the Materials on page 4 AS 400 or iSeries Systems Set the SCSI address switch...

Страница 21: ...be using the system 1 __ If it is on perform a controlled shutdown of the system as follows For RS 6000 or pSeries Systems To do a fast shutdown type shutdown F from the console You must have root aut...

Страница 22: ...y device on the SCSI bus connect the cable to the host system see Figure 4 on page 9 Connect a terminator to the unused SCSI bus cable connector v If the 7210 DVD RAM Drive is part of a multiple devic...

Страница 23: ...ic external storage devices including the 7210 DVD RAM Drive Contact your IBM authorized support personnel for information about valid attached devices and the configurations allowed by the system 3 W...

Страница 24: ...the following 1 DANGER An electrical outlet that is not correctly wired could place hazardous voltage on metal parts of the system or the products that attach to the system It is the customer s respo...

Страница 25: ...figure the 7210 DVD RAM Drive to the host system software by doing the following a Log into the host system AIX operating system Note You must have root authority to install or remove the 7210 DVD RAM...

Страница 26: ...been attached 4 __ In the Opt column type 9 next to the adapter then press Enter The Work with Storage Controller Resources screen now displays the adapter on the first row The 7210 DVD RAM Drive sho...

Страница 27: ...t is an International Organization for Standardization ISO symbol for a push button switch Load Unload Button The load unload button 3 enables the DVD RAM tray to be inserted or ejected To insert or e...

Страница 28: ...ng indicator lights Power On Light When the 7210 DVD RAM Drive is turned on the power on light 1 comes on and is green Status Light The status light 5 can be in one of several states v The light is of...

Страница 29: ...d button v Gently push the disc tray completely into the disc opening If the DVD disc fails to eject refer to the procedure for manually removing a disc in the 7210 Model 025 DVD RAM Drive Service Gui...

Страница 30: ...16 7210 DVD RAM Drive Setup and Operator Guide...

Страница 31: ...system manuals Attention Failure to inform the operating system before you add or delete a device may result in data loss or a system fault 3 __ If it is on perform a controlled shutdown of the syste...

Страница 32: ..._ Ensure that the terminator is on the last device on the SCSI bus see Step 9 Installing the SCSI Bus Terminator on page 8 CAUTION Do not remove the covers of the unit An invisible laser beam may be p...

Страница 33: ...lugs approved by the appropriate testing organization for the specific countries where they are used For units set at 230 V outside of U S Use a Cable Set consisting of a minimum 18 AWG cable and grou...

Страница 34: ...mark 5 14F0015 South Africa Bangladesh Burma Pakistan South Africa Sri Lanka 6 14F0033 United Kingdom Bahrain Bermuda Brunei Channel Islands Cyprus Ghana Hong Kong India Iraq Ireland Jordan Kenya Kuwa...

Страница 35: ...ation in this book is Very Satisfied Satisfied Neutral Dissatisfied Very Dissatisfied Accurate h h h h h Complete h h h h h Easy to find h h h h h Easy to understand h h h h h Well organized h h h h h...

Страница 36: ...lopment Department 542 3605 Hwy 52 North Rochester Minnesota 55901 7829 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Страница 37: ......

Страница 38: ...Part Number 19P3654 Printed in U S A SY44 0079 00 1P P N 19P3654...

Отзывы: