f.
Press
the
adapter
firmly
into
the
adapter
connector.
g.
Reinstall
the
PCI-X
dividers
between
the
Active
PCI-X
adapter
slots.
h.
Push
down
on
the
blue
adapter
guide
to
keep
the
adapter
steady.
i.
Close
the
tab;
then,
push
down
on
the
orange
adapter
retention
latch
until
it
clicks
into
place,
securing
the
adapter.
6.
Connect
the
internal
cables
to
the
adapter.
7.
If
you
have
other
options
to
install
or
remove,
do
so
now.
8.
Close
the
server
cover;
then,
go
to
Cabling
a
ServeRAID
adapter
Some
xSeries
445
models
come
with
an
optional
IBM
ServeRAID
™
adapter
installed
to
control
the
internal
hot-swap
hard
disk
drives.
If
you
are
installing
an
optional
IBM
ServeRAID
adapter,
see
the
ServeRAID
documentation
and
the
cabling
information
in
this
section
to
install
the
ServeRAID
adapter.
Servers
that
do
not
come
with
an
IBM
ServeRAID
adapter
installed
come
with
two
SCSI
cables:
v
One
end
of
the
first
SCSI
cable
is
attached
to
the
connector
on
the
SCSI
backplane,
and
the
other
end
is
attached
to
the
connector
for
the
integrated
SCSI
controller
under
fans
3
and
4.
v
The
second
SCSI
cable
is
preinstalled
along
the
inside
of
the
server
and
both
ends
are
loose
inside
the
server.
When
you
install
a
ServeRAID
adapter,
you
will
connect
this
cable
to
the
adapter
and
to
the
SCSI
backplane.
The
following
procedure
describes
the
internal
cabling
for
installing
a
ServeRAID
adapter.
Important:
When
installing
multiple
ServeRAID
adapters
in
a
server
that
has
the
PCI-X
slot
enabled
for
high
scan
(boot)
priority,
ensure
that
the
ServeRAID
adapter
controlling
the
startup
(boot)
drive
is
installed
in
a
PCI
slot
that
is
scanned
before
the
PCI
slots
that
contain
the
other
ServeRAID
adapters.
See
Complete
the
following
steps
to
cable
the
ServeRAID
adapter:
1.
Read
the
safety
information
beginning
on
page
and
2.
Turn
off
the
server
and
disconnect
all
power
cords
and
external
cables;
then,
open
the
server
cover
(see
3.
Remove
fans
3
and
4,
which
are
located
just
behind
the
PCI-X
slots
(see
the
illustration
on
page
5
for
the
locations
of
the
fans).
4.
Disconnect
the
short
SCSI
cable
from
the
SCSI
backplane
and
the
integrated
SCSI
controller
on
the
I/O
board;
then,
store
this
short
cable
in
a
safe
place
for
future
use.
5.
Install
the
ServeRAID
adapter
in
a
PCI-X
slot
(see
Chapter
2.
Installing
options
29
Содержание eServer 445 xSeries
Страница 3: ...xSeries 445 Type 8870 Installation Guide ERserver ...
Страница 62: ...50 xSeries 445 Type 8870 Installation Guide ...
Страница 70: ...58 xSeries 445 Type 8870 Installation Guide ...
Страница 78: ...66 xSeries 445 Type 8870 Installation Guide ...
Страница 80: ...68 xSeries 445 Type 8870 Installation Guide ...
Страница 92: ...80 xSeries 445 Type 8870 Installation Guide ...
Страница 122: ...110 xSeries 445 Type 8870 Installation Guide ...
Страница 123: ......
Страница 124: ... Part Number 02R2783 Printed in USA 1P P N 02R2783 ...