
#odmget
errnotify
|
grep
diagela
/*
you
should
see
something
similar
to
the
following
*/
1.
Verify
that
automatic
error
analysis
is
enabled.
#odmget
errnotify
|
grep
diagela
/*
you
should
see
something
similar
to
the
following
*/
en_name
=
"diagela"
en_method
=
"/usr/lpp/diagnostics/bin/diagela
$6
$9"
en_name
=
"diagela_PEND"
en_method
=
"/usr/lpp/diagnostics/bin/diagela
$6
$9"
en_name
=
"diagela_TEMP"
en_method
=
"/usr/lpp/diagnostics/bin/diagela
$6
$9"
en_name
=
"diagela_FIRM"
en_method
=
"/usr/lpp/diagnostics/bin/diagela
sysplanar0
$9"
en_name
=
"diagela_PDE"
en_method
=
"/usr/lpp/diagnostics/bin/diagela
sysplanar0
$9"
en_method
=
"/usr/lpp/diagnostics/bin/diagela
$6
$9"
en_method
=
"/usr/lpp/diagnostics/bin/diagela
$6
$9"
en_name
=
"diagela_RAID"
en_method
=
"/usr/lpp/diagnostics/bin/diagela
$6
$9"
en_name
=
"diagela_SE"
en_method
=
"/usr/lpp/diagnostics/bin/diagela
$9
$6
$1"
en_name
=
"diagela_SPUR"
en_method
=
"/usr/lpp/diagnostics/bin/diagela
sysplanar0
$9"
en_method
=
"/usr/lpp/diagnostics/bin/diagela
$6
$9"
2.
Verify
CIM
automatic
error
analysis
subscription
exists.
#odmget
PDiagAtt
|
grep
CIM
/*
you
should
see
something
like
the
following
*/
DType
=
"CIM_DIAG1"
DApp
=
"/opt/freeware/cimom/pegasus/bin/CIMDiagListener.sh"
DType
=
"CIM_DIAG2"
DApp
=
"/opt/freeware/cimom/pegasus/bin/CIMDiagListener.sh"
3.
Check
to
see
if
cimserver
is
running
on
the
agent
system.
#
ps
-ef
|
grep
cims
root
303216
307200
0
12:08:05
pts/1
0:00
grep
cims
root
372776
389264
0
Jan
25
-
0:00
/opt/freeware/cimom/pegasus/bin/cimservera
root
389264
1
0
Jan
25
-
0:15
[cimserve]
4.
Check
to
see
if
cimlistener
is
running
on
the
agent
system.
#
ps
-ef
|
grep
cimlist
/*
root
303220
307200
0
12:09:25
pts/1
0:00
grep
cimlist
root
430258
1
0
Jan
25
-
3:43
cimlistener
5.
Check
to
see
if
CIM_diagd
is
running.
#
ps
-ef
|
grep
CIM_diagd
/*
check
to
see
if
CIM_diagd
is
running
*/
root
303224
307200
0
12:10:01
pts/1
0:00
grep
CIM_diagd
root
413708
1
0
Jan
25
-
0:00
/opt/freeware/cimom/pegasus/bin/CIM_diagd
6.
Check
if
the
hardware
error
has
been
written
to
the
error
log.
#
errpt
-a
|
pg
7.
Make
sure
to
always
start/stop
the
cimserver
and
cimlistener
with
the
provided
scripts:
/opt/ibm/icc/cimom/bin/startcim
/opt/ibm/icc/cimom/bin/startcimlist
/opt/ibm/icc/cimom/bin/stopcim
/opt/ibm/icc/cimom/bin/stopcimlist
88
DR550
Version
4.5
Problem
Determination
and
Service
Guide
Содержание DR550
Страница 1: ...IBM System Storage DR550 Version 4 5 Problem Determination and Service Guide GA32 0576 00...
Страница 2: ......
Страница 3: ...IBM System Storage DR550 Version 4 5 Problem Determination and Service Guide GA32 0576 00...
Страница 4: ...ii DR550 Version 4 5 Problem Determination and Service Guide...
Страница 8: ...vi DR550 Version 4 5 Problem Determination and Service Guide...
Страница 20: ...xviii DR550 Version 4 5 Problem Determination and Service Guide...
Страница 28: ...xxvi DR550 Version 4 5 Problem Determination and Service Guide...
Страница 78: ...50 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 88: ...60 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 96: ...68 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 102: ...74 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 108: ...80 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 118: ...90 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 178: ...DR2 power cabling Figure 77 DR2 power cabling primary rack 150 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 179: ...Figure 78 DR2 power cabling primary rack and expansion rack Appendix A DR1 and DR2 cabling diagrams 151...
Страница 180: ...Figure 79 DR2 power cabling expansion rack 152 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 185: ...DR1 power cabling Figure 88 DR1 Power Cabling Appendix A DR1 and DR2 cabling diagrams 157...
Страница 186: ...Figure 89 DR1 Power Cabling 158 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 190: ...Figure 95 Storage Controller port identification 162 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 191: ...Figure 96 Expansion Drawer port identification Appendix A DR1 and DR2 cabling diagrams 163...
Страница 192: ...Figure 97 Power Control Assembly PCA port identification 164 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 246: ...218 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 252: ...224 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 257: ......
Страница 258: ...Printed in USA GA32 0576 00...