System
Storage
Archive
Manager
disk
storage
pool
The
DR550
includes
one
small
storage
pool
(500
GB)
with
instructions
in
the
DR550
Installation
Roadmap
on
how
to
expand
it
or
add
additional
storage
pools.
The
DR550
has
been
preconfigured
with
a
single
disk
storage
pool
(ARCHIVEPOOL).
Only
the
first
free
raw
logical
volume
has
been
defined
into
the
ARCHIVEPOOL.
The
customer
is
expected
to
add
additional
volumes
to
the
storage
pool
or
create
new
storage
pools
as
necessary.
SSAM
storage
configuration
details
for
the
remaining
DR1
and
DR2
configurations
are
presented
in
the
DR550
Installation
Roadmap
.
The
DR550
will
come
from
the
factory
with
a
small
data
object
stored
into
the
SSAM
Server.
The
retention
policy
on
the
object
is
permanent.
The
reason
that
this
is
important
is
that
SSAM
allows
the
customer
to
disable
the
data
retention
protection
capability
on
the
SSAM
Server
if
there
is
no
data
stored
into
the
SSAM
Server.
Since
the
small
object
will
never
expire
on
the
SSAM
Server
in
the
DR550,
a
customer
should
never
be
able
to
disable
data
retention
protection.
SSAM
Server
failures
To
diagnose
SSAM
Server
failures,
do
the
following:
v
SSAM
server
directory
is:
/usr/tivoli/tsm/server/bin
.
Contains
server
error
log:
dsmserv.err
.
v
Problem
determination
via
command
line:
dsmadmc
.
Perform
different
query
commands
for
problem
determination.
v
Check
the
SSAM
activity
log.
You
can
run
the
following
command
from
administrative
command
line:
Q
actlog
begint=-hh:mm
v
If
SSAM
server
is
not
accessible,
kill
process
dsmserv
.
Requires
restart
of
the
SSAM
server.
DR550-specific
version
of
DS4000
Storage
Manager
The
DR550
specific
version
of
the
DS4000
Storage
Manager
software
(hereafter
referred
to
as
the
DS4000
Storage
Manager
for
DR550)
will
be
available
from
the
DR550
support
Web
site
for
download.
This
version
has
been
enhanced
to
provide
additional
protection.
Storage
Manager
is
designed
to
support
centralized
management
of
the
DR550
Storage
Controllers
in
the
DR550.
Storage
Manager
is
designed
to
allow
administrators
to
quickly
configure
and
monitor
storage
from
a
Java-based
GUI
interface.
It
is
also
designed
to
allow
them
to
customize
and
change
settings
as
well
as
configure
new
volumes,
define
mappings,
handle
routine
maintenance
and
dynamically
add
new
enclosures
and
capacity
to
existing
volumes—without
interrupting
user
access
to
data.
Failover
drivers,
performance-tuning
routines
and
cluster
support
are
also
standard
features
of
Storage
Manager.
Using
the
DS4000
Storage
Manager
for
DR550,
the
DR550
Storage
Controller
is
set
up
in
a
single
partition
at
the
factory
(even
though
it
has
capability
for
2
partitions).
As
shown
in
cabling
diagrams,
the
DR550
SSAM
Servers
are
connected
to
the
DR550
Storage
Controllers
via
Ethernet
cables.
This
connection
is
used
to
manage
the
DR550
Storage
Controllers.
For
the
single
node
configuration,
DS4000
Storage
Manager
runs
in
the
DR550
SSAM
Server.
For
the
dual
node
configuration,
DS4000
Storage
Manager
runs
in
both
servers.
Note:
Only
this
special
version
of
DS4000
Storage
Manager
should
be
used
with
the
DR550.
You
should
not
use
this
version
with
other
DS4000
disk
systems
Chapter
10.
Software
overview
77
Содержание DR550
Страница 1: ...IBM System Storage DR550 Version 4 5 Problem Determination and Service Guide GA32 0576 00...
Страница 2: ......
Страница 3: ...IBM System Storage DR550 Version 4 5 Problem Determination and Service Guide GA32 0576 00...
Страница 4: ...ii DR550 Version 4 5 Problem Determination and Service Guide...
Страница 8: ...vi DR550 Version 4 5 Problem Determination and Service Guide...
Страница 20: ...xviii DR550 Version 4 5 Problem Determination and Service Guide...
Страница 28: ...xxvi DR550 Version 4 5 Problem Determination and Service Guide...
Страница 78: ...50 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 88: ...60 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 96: ...68 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 102: ...74 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 108: ...80 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 118: ...90 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 178: ...DR2 power cabling Figure 77 DR2 power cabling primary rack 150 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 179: ...Figure 78 DR2 power cabling primary rack and expansion rack Appendix A DR1 and DR2 cabling diagrams 151...
Страница 180: ...Figure 79 DR2 power cabling expansion rack 152 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 185: ...DR1 power cabling Figure 88 DR1 Power Cabling Appendix A DR1 and DR2 cabling diagrams 157...
Страница 186: ...Figure 89 DR1 Power Cabling 158 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 190: ...Figure 95 Storage Controller port identification 162 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 191: ...Figure 96 Expansion Drawer port identification Appendix A DR1 and DR2 cabling diagrams 163...
Страница 192: ...Figure 97 Power Control Assembly PCA port identification 164 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 246: ...218 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 252: ...224 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 257: ......
Страница 258: ...Printed in USA GA32 0576 00...