To return the chassis to customer service for replacement, see Appendix A, “Getting
help and technical assistance,” on page 57, to help you gather all the required
information that is necessary to return a component. After you remove the chassis
unit, securely pack the RackSwitch unit for shipping.
To replace the RackSwitch chassis in the rack, see Chapter 2, “Installing the
RackSwitch and options,” on page 13.
Configuring Vital Product Data after a switch replacement
After you replace a RackSwitch, you must update the new switch with the VPD of
the RackSwitch being removed to avoid losing the licensed electronic entitlement
data of the RackSwitch. The VPD includes the model and serial number of the
switch. For more information on locating the VPD, see “Before installing the
RackSwitch” on page 13.
To update the VPD on a new switch, complete the following steps.
1. Log in to the switch and in the CLI mode, type
RS G8124>ibmnos
2. At the Password prompt, enter the switch password, and press Enter. The
default password is
admin
.
3. In the main menu, enter the MTM number for the replacement switch. For
example:
/boot/mtm 8036-AFX
where
8036-AFX
is the MTM of the unit that is being replaced.
4. Enter the serial number for the replacement switch. For example:
/boot/esn 1000001
where
1000001
is the serial number of the unit that is being replaced.
5. Reset the switch using the following command:
/boot/reset
6. When prompted to confirm the reset, enter
y
. The switch reboots.
7. After the switch reboots, at the command prompt, verify that the VPD
information is correct by issuing the
show sys-info
command using the ISCLI
interface or the
/info/sys/general
command using MenuCLI interface.
ISCLI interface output example:
show sys-info
Chapter 3. Removing and replacing the RackSwitch and components
41
Содержание BNT RackSwitch G8124
Страница 1: ...IBM System Networking RackSwitch G8124 and G8124 E Installation Guide...
Страница 2: ......
Страница 3: ...IBM System Networking RackSwitch G8124 and G8124 E Installation Guide...
Страница 7: ...DANGER Rack mounted devices are not to be used as shelves or work spaces L002 Safety v...
Страница 9: ...Safety vii...
Страница 14: ...xii IBM System Networking RackSwitch G8124 and G8124 E Installation Guide...
Страница 64: ...48 IBM System Networking RackSwitch G8124 and G8124 E Installation Guide...
Страница 72: ...56 IBM System Networking RackSwitch G8124 and G8124 E Installation Guide...
Страница 76: ...60 IBM System Networking RackSwitch G8124 and G8124 E Installation Guide...
Страница 84: ...68 IBM System Networking RackSwitch G8124 and G8124 E Installation Guide...
Страница 87: ......
Страница 88: ...Part Number 00AY390 Printed in USA 1P P N 00AY390...