Table
12.
DIMM
boot
errors
(continued)
Code
Message
Description
Action
No
local
memory
on
CPU1
No
local
memory
on
IBM
PowerXCell
8i
processor
1.
There
should
be
DIMMs
on
IBM
PowerXCell
8i
processor
1,
but
this
is
not
the
case.
No
local
memory
on
CPU2
No
local
memory
on
IBM
PowerXCell
8i
processor
2.
There
should
be
DIMMs
on
IBM
PowerXCell
8i
processor
2,
but
this
is
not
the
case.
Slots
1
and
2
should
both
have
DIMMs
plugged
Either
slot
1
or
slot
2
has
no
DIMMs
plugged,
but
this
should
not
be
the
case.
Slots
5
and
6
should
both
have
DIMMs
plugged
Either
slot
5
or
slot
6
has
no
DIMMs
plugged,
but
this
should
not
be
the
case.
Slots
[3,7]
and
[4,8]
should
have
both
DIMMs
plugged
Slots
3,4,7,8
are
not
completely
plugged.
Slots
1,2,5,6
are
plugged,
additional
slots
are
plugged,
but
not
all
of
3,4,7,8.
E1140
Slots
x
and
y
are
plugged
with
different
DIMM
types.
Disabling
slots.
The
type
or
the
speed
bin
of
the
two
DIMMs
on
a
given
channel
differs.
Replace
the
DIMM
with
a
supported
DIMM.
See
Chapter
3,
“Parts
listing,”
on
page
27
for
details
of
supported
DIMMs.
E1150
DIMMs
in
slots
x
and
y
have
different
amount
of
ranks.
Disabling
slots
a
and
b
DIMM
rank
count
on
channel
differs.
The
number
of
ranks
of
the
two
DIMMs
on
a
given
channel
differs.
Replace
the
DIMMs
with
ones
of
the
same
type.
See
Chapter
3,
“Parts
listing,”
on
page
27
for
details
of
supported
DIMMs.
E1160
DIMMs
on
CPUx
have
different
types
on
channel
1
and
2.
Disabling
slots
a
and
b.
DIMM
types
across
channels
differ.
The
type
or
speed
bin
of
the
DIMMs
on
CH0
is
different
than
the
type
of
the
DIMMs
on
CH1.
Replace
the
DIMMs
with
ones
of
the
same
type.
See
Chapter
3,
“Parts
listing,”
on
page
27
for
details
of
supported
DIMMs.
W1170
DIMMs
on
CPux
have
different
speed
bins
on
channel
1
and
2.
DIMM
speed
bins
across
channels
differs.
Speed
bins
on
Chx
are
greater
than
those
on
CHy
Replace
the
DIMMs
with
ones
of
the
same
type.
See
Chapter
3,
“Parts
listing,”
on
page
27
for
details
of
supported
DIMMs.
W1180
DIMMs
on
CPux
have
different
rank
count
on
channel
1
and
2.
Truncating
slots
a
and
b.
DIMM
rank
count
across
channels
differs
Replace
the
DIMMs
with
ones
of
the
same
type.
See
Chapter
3,
“Parts
listing,”
on
page
27
for
details
of
supported
DIMMs.
Chapter
5.
Diagnostics
and
troubleshooting
81
Содержание BladeCenter QS22 Type 0793
Страница 1: ...BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Страница 8: ...Index 135 vi BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Страница 44: ...26 BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Страница 72: ...54 BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Страница 156: ...138 BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Страница 157: ......
Страница 158: ...Part Number 44R5162 1P P N 44R5162...