Check Procedures 31
Start
This is the entry point for all check procedures. The check procedures use
failure symptoms, Power-On Self Test (POST) error messages, or beeps to
help determine the defective field replaceable unit (FRU). Follow the
suggested check procedures or use the diagnostics diskette to determine the
problem FRU.
IMPORTANT: Replace FRUs ONLY when it is determined that the error is not a
result of software, loose contacts, or dirty component surfaces. Any FRU
change should be verified by running a complete test (“Diagnostics - All
Tests” in PC-Doctor diagnostics program).
This book comes with a diagnostic program diskette. This diskette should be
used ONLY with 2174 Service Level A (SL-A) IBM Aptiva Personal
Computers. Do not use this diskette on other models.
POST error messages are displayed on the screen after the IBM logo.
Meanwhile, error beeps could be issued to help diagnose system problem.
Please refer to “Index of Symptoms, Messages, or Beeps” on page 35 for
additional help.
All voltages in the check procedures are positive unless otherwise indicated.
Use frame ground for all voltage checks unless otherwise specified.
IMPORTANT: There is a Power Override switch located at the back of the
machine, just above the connector for the power cable. If the system
does not power on after pressing the power button situated on the front
of the machine, please check the power cable and the Power Override
switch. If the Power Override switch is switched on, no power is supplied
to the system.
NOTE: If the check procedures instruct you to replace a FRU and the error
message persists, an option adapter card might be causing the failure.
Remove all option adapter cards, one at a time, until the error changes
or the problem is no longer apparent. Replace the last option adapter
card removed.
The hard disk drive contains pre-loaded software. Refer to "Software Recovery
Procedure 103" to reinstall the original software. Be sure to reload the software
on the primary hard disk drive (Drive C) when replacing it.
IMPORTANT: The drives in the system you are servicing may have been
rearranged, or the drive startup sequence has changed. Be extremely
careful during write operations, such as copying, saving, or formatting.
Data or programs can be overwritten if you select an incorrect drive. Ask
the customer to back up any additional software from the hard disk
drive before you reload the software.
Содержание Aptiva 2174
Страница 12: ...VI...
Страница 13: ...Notices VII...
Страница 14: ...VIII...
Страница 15: ...Notices IX...
Страница 16: ...X...
Страница 24: ...XVIII...
Страница 25: ...Notices XIX...
Страница 26: ...XX...
Страница 80: ...48...
Страница 95: ...Check Procedures 63 009 Replace the power supply End...
Страница 100: ...68...
Страница 108: ...76 Windsor3 fm Page 76 Monday August 2 1999 1 13 PM...
Страница 136: ...104...
Страница 163: ...Copyright IBM Corp 1998 131 Safety Inspection Guide General Guidelines 132...
Страница 167: ...Parts Catalog 135 Assembly for Machine Type 2174 Assembly 1a Machine Type 2174 System Unit Interior...
Страница 174: ...142...
Страница 176: ...144...
Страница 180: ...148...
Страница 184: ...152...
Страница 186: ......