Removing
and
installing
I/O
modules
For
blade
server
communication
with
the
network,
the
BladeCenter
T
unit
supports
up
to
four
hot-swap
I/O
modules.
Table
5
identifies
the
types
of
I/O
modules
that
you
can
install
in
each
I/O-module
bay.
Go
to
the
IBM
Support
Web
site
at
http://www.ibm.com/support/
to
see
the
list
of
supported
I/O
modules.
The
BladeCenter
T
unit
supports
a
minimum
of
one
hot-swap
Ethernet
switch
module
or
pass-thru
module,
in
I/O-module
bay
1
or
2.
This
I/O
module
provides
an
internal
connection
to
an
integrated
Ethernet
controller
in
all
the
blade
servers
in
the
BladeCenter
T
unit,
up
to
eight
internal
connections
per
I/O
module.
To
provide
an
internal
connection
for
the
second
integrated
Ethernet
controller
in
each
blade
server,
install
an
Ethernet
switch
module
or
pass-thru
module
in
the
available
I/O-module
bay
of
the
pair
(I/O-module
bay
1
or
bay
2).
The
management
modules
are
connected
to
the
switch
module
through
the
backplane
using
a
transformerless
100
Mbps
connection
and
an
I2C
interface.
The
BladeCenter
T
unit
supports
two
additional
I/O
modules
in
I/O-module
bays
3
and
4.
Each
of
these
I/O
modules
provides
an
internal
connection
to
one
of
the
two
network-interface
controllers
on
each
of
the
I/O
expansion
options
that
are
installed
on
blade
servers
in
the
BladeCenter
T
unit.
The
I/O
module
must
be
compatible
with
the
network
interface
on
each
of
the
I/O
expansion
options.
For
example,
if
you
install
a
Fibre
Channel
I/O
expansion
card
on
a
blade
server,
the
I/O
modules
that
you
install
in
I/O-module
bays
3
and
4
must
be
Fibre
Channel
switch
modules
or
pass-thru
modules.
Important:
The
switch
modules
in
I/O
module
bays
3
and
4
and
all
blade
server
interface
options
in
the
BladeCenter
T
unit,
must
use
the
same
interface
type.
For
example,
if
you
install
an
Ethernet
interface
option
on
a
blade
server,
the
switch
modules
that
you
install
in
I/O
module
bays
3
and
4
must
be
Ethernet.
All
other
interface
options
in
the
BladeCenter
T
unit
must
also
be
Ethernet
interface
options.
Note:
You
can
use
a
pass-thru
module
in
any
I/O-module
bay,
provided
that
the
associated
controller
in
the
blade
servers
or
I/O
expansion
options
is
compatible
with
it.
The
following
table
summarizes
the
types
of
modules
that
can
be
used
in
each
I/O-module
bay.
See
“Rear
view”
on
page
15
for
the
location
of
the
I/O-module
bays
on
the
BladeCenter
T
unit.
Table
5.
Hot-swap
I/O
module
types
by
location
for
redundancy
Bays
I/O-module
function
Permissible
I/O
module
1
and
2
Network
connections
1
and
2
(Ethernet)
for
all
blade
servers
in
the
BladeCenter
T
unit
One
of
the
following
combinations:
v
Two
Ethernet
switch
modules
v
Two
pass-thru
modules
v
One
Ethernet
switch
module
and
one
pass-thru
module
60
BladeCenter
T
Type
8720
and
8730:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
Содержание 87302RU
Страница 1: ...BladeCenter T Type 8720 and 8730 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 2: ......
Страница 3: ...BladeCenter T Type 8720 and 8730 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 10: ...viii BladeCenter T Type 8720 and 8730 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 98: ...88 BladeCenter T Type 8720 and 8730 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 120: ...110 BladeCenter T Type 8720 and 8730 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 136: ...126 BladeCenter T Type 8720 and 8730 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 137: ...Laser Klass 1 Appendix B Related service information 127 ...
Страница 138: ...128 BladeCenter T Type 8720 and 8730 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 139: ...Appendix B Related service information 129 ...
Страница 140: ...130 BladeCenter T Type 8720 and 8730 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 141: ...Appendix B Related service information 131 ...
Страница 142: ...Luokan 1 Laserlaite 132 BladeCenter T Type 8720 and 8730 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 156: ...146 BladeCenter T Type 8720 and 8730 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 157: ...Appendix B Related service information 147 ...
Страница 158: ...148 BladeCenter T Type 8720 and 8730 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 159: ...Appendix B Related service information 149 ...
Страница 160: ...150 BladeCenter T Type 8720 and 8730 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 166: ...156 BladeCenter T Type 8720 and 8730 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 174: ...164 BladeCenter T Type 8720 and 8730 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 179: ......
Страница 180: ... Part Number 25K8107 1P P N 25K8107 ...