Attention:
When
you
handle
static-sensitive
devices,
take
precautions
to
avoid
damage
from
static
electricity.
For
details
about
handling
these
devices,
see
“Handling
static-sensitive
devices”
on
page
28.
3.
Remove
the
server
cover
(see
“Removing
the
cover
and
bezel”
on
page
28).
4.
Remove
the
divider
that
contains
the
battery
holder
from
the
server.
5.
Open
the
retaining
clip
on
each
end
of
the
connector.
6.
Touch
the
static-protective
package
that
contains
the
ServeRAID-MR10k
SAS
controller
to
any
unpainted
metal
surface
on
the
outside
of
the
server;
then,
remove
the
controller
from
the
package.
7.
Turn
the
controller
so
that
the
keys
align
correctly
with
the
slot.
8.
Insert
the
controller
into
the
connector
by
aligning
the
edges
of
the
controller
with
the
slots
at
the
ends
of
the
connector.
Attention:
Incomplete
insertion
might
cause
damage
to
the
server
or
the
ServeRAID-MR10k
SAS
controller.
9.
Firmly
press
the
controller
straight
down
into
the
connector
by
applying
pressure
on
both
ends
simultaneously.
The
retaining
clips
snap
into
the
locked
position
when
the
controller
is
seated
in
the
connector.
10.
Install
the
battery
in
the
divider
that
contains
the
battery
holder.
11.
Connect
the
battery
cable
to
the
ServeRAID-MR10k
SAS
controller.
12.
Install
the
divider
that
contains
the
battery
holder
in
the
server.
13.
Route
the
battery
cable
through
the
cable
routing
guides
on
the
divider
to
the
controller.
If
you
have
other
devices
to
install
or
remove,
do
so
now.
Otherwise,
go
to
“Completing
the
installation”
on
page
50.
Installing
an
adapter
The
following
notes
describe
the
types
of
adapters
that
the
server
supports
and
other
information
that
you
must
consider
when
you
install
an
adapter:
v
Locate
the
documentation
that
comes
with
the
adapter
and
follow
those
instructions
in
addition
to
the
instructions
in
this
section.
If
you
must
change
the
switch
setting
or
jumper
settings
on
the
adapter,
follow
the
instructions
that
come
with
the
adapter.
v
See
the
documentation
that
comes
with
the
operating
system
for
information
about
enabling
a
hot-plug
PCI
Express
slot.
v
Avoid
touching
the
components
and
gold-edge
connectors
on
the
adapter.
v
The
server
scans
devices
and
PCI
Express
slots
to
assign
system
resources
in
the
following
order:
integrated
Ethernet
controller,
integrated
SAS
controller,
and
then
PCI
Express
slots
1
through
7.
If
you
have
not
changed
the
default
startup
sequence,
the
server
starts
the
devices
in
the
following
order:
DVD
drive,
USB-attached
diskette
drive,
integrated
SAS
controller,
PCI
Express
slots
1
through
7,
and
the
integrated
Ethernet
controller.
Note:
To
change
the
startup
sequence,
start
the
Configuration/Setup
Utility
program
and
select
Start
Options
from
the
main
menu.
See
“Using
the
Configuration/Setup
Utility
program”
on
page
54
for
details
about
using
the
Configuration/Setup
Utility
program.
v
You
do
not
have
to
turn
off
the
server
to
install
a
hot-plug
adapters
in
slots
6
and
7.
However,
you
must
turn
off
the
server
when
you
perform
any
steps
that
involve
installing
or
removing
cables.
30
IBM
System
x3850
M2
and
System
x3950
M2
Type
7141:
User’s
Guide
Содержание 72335LU - System x3850 M2
Страница 1: ...IBM System x3850 M2 and System x3950 M2 Type 7141 User s Guide ...
Страница 2: ......
Страница 3: ...IBM System x3850 M2 and System x3950 M2 Type 7141 User s Guide ...
Страница 82: ...70 IBM System x3850 M2 and System x3950 M2 Type 7141 User s Guide ...
Страница 84: ...72 IBM System x3850 M2 and System x3950 M2 Type 7141 User s Guide ...
Страница 90: ...78 IBM System x3850 M2 and System x3950 M2 Type 7141 User s Guide ...
Страница 94: ...82 IBM System x3850 M2 and System x3950 M2 Type 7141 User s Guide ...
Страница 95: ......
Страница 96: ... Part Number 40M2362 Printed in USA 1P P N 40M2362 ...