046 EC STOPPED AT
STATE
<state>
No
Controller self–test and
initialization sequence
was halted at <state>,
where <state> is one of
10 numerically coded
messages.
Contact your IBM service
representative.
056 HAMMER COIL OPEN
No
Electrical malfunction of
one or more hammer
coils.
(You can continue to print
with degraded print
quality.) Contact your IBM
service representative.
057 CLOSE PLATEN
Yes
Forms thickness lever is
raised to the open
position.
Lower the forms thickness
lever.
058 SHUTTLE JAM
SEE SETUP GUIDE
No
No shuttle movement or
the shuttle is moving at
the wrong speed.
Make sure the ribbon is not
twisted and the forms
thickness lever is set
correctly. If the fault
reoccurs, contact your IBM
service representative.
059 CANCEL PRINT
ACTIVE
N/A
Non–error status
message.
No action necessary.
060 PRINTER HOT
No
Controller board sensors
report high temperatures
on the board.
Contact your IBM service
representative.
062 EXHAUST FAN FAULT
Yes
Sensors cannot detect
current in fan circuit.
Power off the printer.
Check for obstruction of
vents and fan airway;
remove any obstructions.
Check for items beneath
the printer blocking cabinet
vents. Power back on the
printer. If this message
reoccurs, contact your IBM
service representative.
NOTE: This message
should not appear on a
Pedestal model. If this
message does appear,
contact your IBM Service
Representative.
Table 12: Fault Messages
Fault Message
Operator
Correctable?
Explanation
Solution
Содержание 6400-i05
Страница 1: ...Setup Guide Cabinet and Pedestal Models 6400i Line Matrix Printers S544 5640 04 ...
Страница 2: ......
Страница 3: ...S544 5640 04 Setup Guide Cabinet and Pedestal Models 6400i Line Matrix Printers ...
Страница 6: ......
Страница 24: ...24 Chapter 1 The IBM 6400 Printer Family ...
Страница 102: ...102 Chapter 3 Changing The Power On Configuration ...
Страница 248: ...248 Chapter 4 RibbonMinder Menu ...
Страница 274: ...274 Chapter 6 Hex Code Printout Figure 70 Sample ASCII Hex Code Printout Figure 71 Sample Coax Hex Code Printout ...
Страница 288: ...288 Chapter 6 Fault Messages ...
Страница 304: ...304 Appendix B Printing Speed ...
Страница 310: ...310 Appendix C Compatibility and Limitations ...
Страница 328: ...328 Appendix D Physical and Logical Unit Types ...
Страница 366: ...366 ...
Страница 369: ......
Страница 370: ...Part Number 75P1626 176811 001A S544 5640 04 07S544564004 1P P N 75P1626 1P75P1626 176811 001 Printed in U S A ...