Select a printer site that meets all of the following requirements:
•
Cabinet models: Permits complete opening of the printer cover and both
doors of the floor cabinet. Allows at least three feet of clearance behind
the printer. (This permits air to circulate freely around the printer and
provides access to the paper stacking area.)
•
Pedestal models: Permits complete opening of the printer cover and
good access to the paper areas at the front and rear of the printer.
•
Has a standard power outlet that supplies 88-135 Volts AC or
178-270 Volts AC power, at 47 to 63 Hz. The printer automatically senses
and adjusts itself to conform to the correct voltage range.
•
Is relatively dust-free.
•
Has a temperature range of 10°
C
to 40° C (50° F to 104° F) and a
relative humidity from 15% to 90% non-condensing.
•
Is located within the maximum allowable cable length to the host
computer. This distance depends on the type of interface you plan to use,
as shown in Table 2.
Table 2. Maximum Interface Connection Cable Length
Interface Type
Maximum Cable Length
PC Parallel
5 meters (15 feet)
IEEE 1284 Parallel
10 meters (32 feet)
Dataproducts Parallel
12 meters (40 feet)
Serial RS 232
15 meters (50 feet)
Serial RS 422
1220 meters (4000 feet)
Twinax (shielded cable)
1500 meters (4920 feet)
Twisted Pair / Type 3
300 meters (985 feet)
Dataproducts Long Line
150 meters (492 feet)
Coax
1500 meters (4920 feet)
Twisted Pair / Type 3
300 meters (985 feet)
Ethernet 10/100Base-T
100 meters (328 feet)
Ethernet 10Base-2
185 meters (607 feet)
Содержание 6400-i05
Страница 1: ...Setup Guide Cabinet and Pedestal Models 6400i Line Matrix Printers S544 5640 04 ...
Страница 2: ......
Страница 3: ...S544 5640 04 Setup Guide Cabinet and Pedestal Models 6400i Line Matrix Printers ...
Страница 6: ......
Страница 24: ...24 Chapter 1 The IBM 6400 Printer Family ...
Страница 102: ...102 Chapter 3 Changing The Power On Configuration ...
Страница 248: ...248 Chapter 4 RibbonMinder Menu ...
Страница 274: ...274 Chapter 6 Hex Code Printout Figure 70 Sample ASCII Hex Code Printout Figure 71 Sample Coax Hex Code Printout ...
Страница 288: ...288 Chapter 6 Fault Messages ...
Страница 304: ...304 Appendix B Printing Speed ...
Страница 310: ...310 Appendix C Compatibility and Limitations ...
Страница 328: ...328 Appendix D Physical and Logical Unit Types ...
Страница 366: ...366 ...
Страница 369: ......
Страница 370: ...Part Number 75P1626 176811 001A S544 5640 04 07S544564004 1P P N 75P1626 1P75P1626 176811 001 Printed in U S A ...