To stop a system by using the ASMI, complete the following steps:
1.
On the ASMI Welcome pane, specify your user ID and password, and click
Log In
.
2.
In the navigation area, click
Power/Restart Control
>
Power On/Off System
. The power state of the
system is displayed.
3.
Specify the settings as required and click
Save setting and power off
.
Stopping a system by using the HMC
You can use the Hardware Management Console (HMC) to stop the system or logical partition.
By default, the managed system is set to power off automatically when you shut down the last running
logical partition on the managed system. If you set the managed system properties on the HMC so that
the managed system does not power off automatically, you must use this procedure to power off your
managed system.
Attention:
Ensure that you shut down the running logical partitions on the managed system before you
power off the managed system. Powering off the managed system without shutting down the logical
partitions first causes the logical partitions to shut down abnormally and can cause data loss. If you use a
Virtual I/O Server (VIOS) logical partition, ensure that all clients are shut down or that the clients have
access to their devices by using an alternative method.
To power off a managed system, you must be a member of one of the following roles:
v
Super administrator
v
Service representative
v
Operator
v
Product engineer
Note:
If you are a product engineer, verify that the customer has shut down all active partitions and
has powered off the managed system. Continue with the procedure only after the status of the server
changes to
Power Off
.
Stopping a system by using the HMC Classic or HMC Enhanced interface
Learn how to stop a system by using the HMC Classic or HMC Enhanced interface.
To stop the system or logical partition by using the HMC Classic or HMC Enhanced interface, complete
the following steps:
1.
In the navigation area, click
Systems Management
>
Servers
.
2.
In the content pane, select the managed system.
3.
In the Tasks area, click
Operations
>
Power Off
.
4.
Select the appropriate power-off mode and click
OK
.
Related information
:
Shutting down and restarting logical partitions
Stopping a system by using the HMC En Tech Preview (Pre-GA) or HMC
E interface
Learn how to stop a system by using the HMC En Tech Preview (Pre-GA) or HMC E
interface.
To stop the system or logical partition by using the HMC En Tech Preview (Pre-GA) or HMC
E interface, complete the following steps:
1.
You must deactivate all the active logical partitions before powering off the system. To deactivate
logical partitions for a specific system, complete the following steps:
48
Power Systems: Installing the 5887 disk drive enclosure
Содержание 5887
Страница 1: ...Power Systems Installing the 5887 disk drive enclosure GI11 9909 02 ...
Страница 2: ......
Страница 3: ...Power Systems Installing the 5887 disk drive enclosure GI11 9909 02 ...
Страница 14: ...xii Power Systems Installing the 5887 disk drive enclosure ...
Страница 60: ...46 Power Systems Installing the 5887 disk drive enclosure ...
Страница 95: ......
Страница 96: ... Part Number 00RW813 Printed in USA GI11 9909 02 1P P N 00RW813 ...