Error
code
Description
Action
035-xxx-s99
Failed
RAID
test:
s
=
number
of
failing
adapter
slot
1.
Check
the
system-error
log
and
replace
any
indicated
failing
devices.
Note:
A
FRU
must
be
replaced
by
a
trained
service
technician
only.
2.
Reseat
the
following
components:
a.
RAID
adapter
in
slot
s
b.
Cable
for
the
RAID
adapter
in
slot
s
c.
Riser
card
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
RAID
adapter
in
slot
s
b.
Cable
for
the
RAID
adapter
in
slot
s
c.
Riser
card
d.
(Trained
service
technician
only)
System
board
075-xxx-000
Failed
power
supply
test.
Replace
the
power
supply.
089-xxx-0nn
Failed
microprocessor
test.
1.
Make
sure
that
the
BIOS
code
is
at
the
latest
level.
2.
(Trained
service
technician
only)
Reseat
the
microprocessor.
3.
(Trained
service
technician
only)
Replace
the
microprocessor.
201-xxx-00n
Failed
memory
test.
Note:
n
=
slot
number
of
failing
DIMM
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
1.
DIMM
identified
by
nn
2.
(Trained
service
technician
only)
System
board
201-xxx-n99
Multiple
DIMM
failure.
Note:
n
=
bank
number
of
failing
pair
1.
See
the
error
text
to
identify
the
failing
DIMMs.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
DIMMs
in
bank
n
b.
(Trained
service
technician
only)
System
board
206-xxx-000
Failed
diskette
drive
test.
1.
Run
the
diskette
drive
test
again
using
another
diskette.
2.
Reseat
the
diskette
drive
cable.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Diskette
drive
b.
(Trained
service
technician
only)
Operator
information
panel
assembly
Chapter
2.
Diagnostics
45
Содержание 306m - eServer xSeries - 8849
Страница 1: ...IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Страница 8: ...vi IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Страница 84: ...68 IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...