Error
code
Description
Action
035-279-001
Adapter
Cache
test
error.
1.
Update
the
RAID
controller
firmware
on
the
RAID
adapter
(see
“Updating
the
firmware”
on
page
103).
2.
Reseat
the
RAID
adapter.
3.
Replace
the
RAID
adapter.
035-280-001
Adapter
Drive
test
error.
Replace
the
attached
drive.
035-281-001
Adapter
Drive
error.
Replace
the
attached
drive.
035-282-001
Adapter
Parameters
set
error.
1.
Update
the
RAID
controller
firmware
on
the
RAID
adapter
(see
“Updating
the
firmware”
on
page
103).
2.
Reseat
the
RAID
adapter.
3.
Replace
the
RAID
adapter.
035-283-001
Adapter
Battery
error.
Replace
the
battery
module
on
the
RAID
adapter.
035-xxx-cnn
c
=
ServeRAID
channel
number,
nn
=
ID
of
failing
fixed
disk
drive.
1.
Check
the
system-error
log
and
replace
any
indicated
failing
devices.
Note:
A
FRU
must
be
replaced
by
a
trained
service
technician
only.
2.
Reseat
the
hard
disk
drive
on
channel
C,
ID
nn.
3.
Replace
the
hard
disk
drive
on
channel
C,
ID
nn.
035-xxx-snn
Failed
hard
disk
drive
with
ID
nn
on
RAID
adapter
in
slot
s.
1.
Check
the
system-error
log
and
replace
any
indicated
failing
devices.
Note:
A
FRU
must
be
replaced
by
a
trained
service
technician
only.
2.
Reseat
the
disk
with
ID
nn
on
adapter
in
slot
s.
3.
Replace
the
disk
with
ID
nn
on
adapter
in
slot
s.
035-xxx-099
No
adapters
were
found.
If
an
adapter
is
installed:
1.
Reseat
the
adapter.
2.
Check
the
adapter
cables
to
be
sure
they
are
secure.
44
IBM
xSeries
306m
Types
8849
and
8491:
Problem
Determination
and
Service
Guide
Содержание 306m - eServer xSeries - 8849
Страница 1: ...IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Страница 8: ...vi IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Страница 84: ...68 IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Страница 141: ......
Страница 142: ...Part Number 31R1183 Printed in USA 1P P N 31R1183...