66
Introduction
This section explains the diagnostic aids, power-on self test (POST) and
diagnostics program (PC-Doctor), that are available for troubleshooting
problems on the system.
Power-On Self Test
Each time you power-on the system, the power-on self test (POST) is initiated.
Several items are tested during POST, but is for the most part transparent to
the user.
POST checks the following:
To start POST, turn on the monitor and then the system unit. The following will
happen:
1. The IBM Aptiva logo will appear on the screen.
2. At this time one of two hot-keys may be used. The F1 key will cause the
system Setup Utility menu to appear. The F9 key will switch the graphical
IBM logo screen to the traditional text-based system startup screen, which
displays BIOS version and system memory tested. For Aptiva, the F9 key
will only work after exiting BIOS Setup.
3. If an error is detected during POST, the IBM logo screen will automatically
switch to the text-based screen and display the error message or code with
a beep. Depending on the criticality of the POST error, the system may halt
and/or display the message “Press <F1> to enter to the Setup or <Enter> to
continue...”
If this message appears, pressing the Enter key will allow the system to
attempt to proceed despite the reported error; pressing F1 will cause the
system Setup Utility menu to appear.
4. If no keyboard keys are pressed, and if POST is completed without errors,
the system will then proceed with the loading of Windows98 or other
operating system from a hard disk drive or diskette drive A or CD-ROM
•
System Board
•
Mouse
•
Memory
•
Parallel Port(s)
•
SVGA Controller
•
Serial Port(s)
•
Hard Disk Drive(s)
•
CD/DVD-ROM Drive(s)
•
Floppy Diskette Drive(s)
•
Sound Controller*
•
Keyboard
Содержание 2158240 - Aptiva E - 2158
Страница 12: ...VI...
Страница 13: ...Notices VII...
Страница 14: ...VIII...
Страница 15: ...Notices IX...
Страница 16: ...X...
Страница 24: ...XVIII...
Страница 25: ...Notices XIX...
Страница 26: ...XX...
Страница 96: ...64 tested Replace the last item tested if the system operates normally after removing the last item...
Страница 162: ...130...
Страница 163: ...Copyright IBM Corp 1998 131 Safety Inspection Guide General Guidelines 132...
Страница 182: ...150...
Страница 187: ......