Table 8. 6Gb/s SAS EBOD I/O Module LED Descriptions
LED
Description
I/O Module OK
Constant green if the I/O module is operating correctly. Flashing green
indicates an I/O module VPD error.
I/O Module Fault
Constant amber if the I/O module is faulty. For replacement procedure
see “Replacing an SBB I/O module” on page 45.
External Host Port Activity
Constant green indicates that there is a host port connection but no
activity. Flashing green indicates that there is a host port connection,
and data is being transferred.
Thermal sensors
Thermal sensors throughout the enclosure and its components monitor the thermal health of the storage
system. Exceeding the limits of critical values will cause the Over-temperature alarm to occur.
Troubleshooting
The following sections describe problems that can occur with your storage systems and some possible
solutions. The module fault LED on the ops panel displays a solid amber color to indicate a fault. All
alarms will also be reported by SES. See Elastic Storage Server Spectrum Scale RAID Administration Guide
and the Maintenance Procedures section in Elastic Storage Server Problem Determination Guide.
Table 9. Alarm Conditions
Status
Severity
PSU alert – loss of DC power from a single PSU
Fault: loss of redundancy
Cooling module fan failure
Fault: loss of redundancy
SBB I/O module detected PSU fault
Fault
PSU removed
Configuration error
Enclosure configuration error (VPD)
Fault: critical
Low temperature warning
Warning
High temperature warning
Warning
Over-temperature alarm
Fault: critical
Under-temperature alarm
Fault: critical
I2C bus failure
Fault: loss of redundancy
Ops panel communication error (I2C)
Fault: critical
SBB I/O module fault
Fault – critical
SBB I/O module removed
Warning
Drive power control fault
Warning; no loss of drive power
Drive power control fault
Fault: critical; loss of drive power
Insufficient power available
Warning
For information on how to remove and replace a module, see "Module Replacement."
34 IBM ESS expansion: Installation and User Guide - Model 084
Содержание 084
Страница 1: ...IBM ESS expansion Version 5 3 5 Installation and User Guide Model 084 IBM SC27462802...
Страница 8: ...viii...
Страница 14: ...xiv IBM ESS expansion Installation and User Guide Model 084...
Страница 22: ...8 IBM ESS expansion Installation and User Guide Model 084...
Страница 32: ...18 IBM ESS expansion Installation and User Guide Model 084...
Страница 38: ...24 IBM ESS expansion Installation and User Guide Model 084...
Страница 42: ...28 IBM ESS expansion Installation and User Guide Model 084...
Страница 62: ...48 IBM ESS expansion Installation and User Guide Model 084...
Страница 66: ...52 IBM ESS expansion Installation and User Guide Model 084...
Страница 77: ......
Страница 78: ...IBM SC27462802...