Manual - STAR-SPOT
4
©Copyright LOTRONIC 2021
2. Connect the end of the cable coming from the first fixture which will have a (female) 3 pin connector to the
input connector of the next fixture consisting of a (male) 3 pin connector. Then, proceed to connect from the
output as stated above to the input of the following fixture and so on
Often, the set up for Master-Slave and Stand-alone operation requires that the first fixture in the chain be initial
-
ized for this purpose via either settings in the control panel or DIP-switches. Secondarily, the fixtures that follow
may also require a slave setting. Please consult the '' Operating Instructions» section in this manual for complete
instructions for this type of setup and configuration.
OPERATING INSTRUCTIONS
NAVIGATION THROUGH THE CONTROL PANEL
Access control panel functions using the four panel buttons located directly underneath the LCD Display..
Button
Function
MENU
Used to access the menu or to return to a previous menu option
UP
Scrolls through menu options in ascending order
DOWN
Scrolls through menu options in descending order
ENTER
Used to select and store the current menu or option within a menu
When a menu function is selected, the display will show immediately the first available option for the selected
menu function. To select a menu item, press <ENTER>.
MENU MAP
Press the <MODE> button repeatedly until you reach the desired menu function. Use the <UP> and <DOWN>
buttons to navigate the menu options. Press the <ENTER> button to select the menu function currently dis
-
played or to enable a menu option. To return to the previous option or menu without changing the value, press
the <MODE> button. After a few seconds, the LED Display will back during operation until another button is
pressed.
Addr
d001-d512
512 address setting
CHnd
15CH
15 channel settings
SLnd
Auto
Automatic mode
Soun
Sound-controlled operation
SHnd
SH 0
Effect 0 (recommended)
SH 1
Effect 1
SH 2
Effect 2
SH 3
Effect 3
SEnS
0-99
Sound sensitivity adjustment
LEd
OFF
Screen off after 5 seconds of inactivity
ON
Screen always on
dISP
no
Display reverse
YES
Display positive
rPAN
no
X motor forward
YES
X motor reverse
rTiL
no
Y motor forward
YES
Y motor reverse
RGB
OFF
SMD off
ON
SMD on
Load
no
YES
Restore factory settings
REST
YES
System reset
UP
DOWN
MENU
ENTER
8.8.8.8.
Содержание STAR-SPOT-BL
Страница 39: ...Manual STAR SPOT 39 www ibiza light com...