background image

©Copyright Lotronic 2017 

 

 

LASER EMISSION DATA  

* As measured under IEC measurement conditions for classification.  

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Laser Power : 
 

SCAN500RGB : 100mW-G-532nm+200mW-R-650nm+200mW-B-445nm 
SCAN1100RGB: 200mW-G-532nm+300mW-R-638nm+600mW-B-445nm   
SCAN2000 RGB: 500mW-G-532nm+500mW-R-638nm+1000mW-B-445nm         
SCAN1100PINK: 500mW-R-638nm+600mW-B-445nm 

 
Specification: 
 

Mains Input: ....................................................................................... AC100~240V, 50/60Hz, total 30W 
Fuse: .................................................................................................... 250V 2A slow blow (20mm glass) 
Menu mode: .............................................. Auto, music, DMX512, Master/slave, ILDA, Artnet RJ45, IRC 
Laser Classification: ..................................................................................................................... Class 3B 
Laser Safety Standard: ................................................................................................... EN60825-1:2014 
Condition Temperature: .......................................................................................................... 10

~40

 

DMX channels ................................................................................................................... 5 / 34 channels 
Dimensions ................................................................................................................ 246 x 211 x 105mm 
Weight: ............................................................................................................................................ 3.5kg 

 
Installation 

The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid 
vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure 
and able to support a weight of 10 times of the unit’s weight. Also always use a safety cable that can hold 12 times 
the weight of the unit when installing the fixture. 

 
DMX512 

1. Install the units in a suitable position (laying or appending). 
2. Use standard XLR microphone cable chain your units together via the XLR connector on the rear of the units. For 
longer cable runs we suggest a terminator at the last fixture. 
3. Assign a DMX address to each the unit.  

Laser Classification 

Class 3B 

Green Laser Medium 

DPSS 532nm 

Red Laser Medium 

LD GaAIAs 638nm,typical 

Blue Laser Medium 

LD InGaN 445nm, typical 

Beam Diameter 

<3mm at aperture 

Divergence(each beam) 

<1.3 mrad 

Divergence(total light) 

<1.3mrad 

Transverse Beam Mode 

TEM

00

 

Cooling 

TEC & Fan Cooling 

Scanning 

High speed scanner 25kpps 

Содержание SCAN500RGB

Страница 1: ...c 2017 1 L LA AS SE ER R W WI IT TH H D DM MX X I IL LD DA A Ref SCAN500RGB SCAN1100RGB SCAN2000RGB SCAN1100PINK USER MANUAL MODE D EMPLOI Imported from China by LOTRONIC SA Avenue Z nobe Gramme 9 148...

Страница 2: ...ce If you sell the unit to another user be sure that he also receives this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecti...

Страница 3: ...e that the unit is firmly fixed to avoid vibration and slipping while operating Always ensure that the structure to which you are attaching the unit is secure and able to support a weight of 10 times...

Страница 4: ...peration description Set the function overview FUNCTION key At every short press on the FUNC button following actions are active INDR DMX 5 CH simplified DMX mode you can set the DMX address via the U...

Страница 5: ...t automatically enter 3 Scene playback only play a scene This mode for the temporary mode restart laser will not automatically enter Slave mode divided into the following two slave modes 1 DMX slave m...

Страница 6: ...CHANNEL DMX value DESCRIPTION CH 1 On off power 0 OFF 1 99 ON 100 199 AUTO 200 254 retain 255 Pattern A closed light pattern B output light CH2 Out of bounds and pattern size 0 49 Out of bounds 50 99...

Страница 7: ...7 Y zooming 2 128 159 Y zooming 3 160 191 Y zooming 4 192 223 Y zooming 5 224 255 Y zooming 6 CH11 Force Segmentation Color 0 Patterns original colors 1 255 The length of the segmented colors CH12 Pat...

Страница 8: ...larger the value the smaller the projection range Table 2 PATTERN B Note Table 2 CH18 CH34 pattern B s channel function except for special instructions only control the pattern B pattern A is not con...

Страница 9: ...Vertical moving 0 63 Manual moving 64 95 vertical 1 96 127 vertical 2 128 159 vertical 3 160 191 vertical 4 192 223 vertical 5 224 255 vertical 6 CH26 X axis Horizontal zooming 0 63 Manual X zooming...

Страница 10: ...ern A is voice activated the CH32 action will also become a voice activated state 0 31 Forward hand drawn gradually 32 63 Reverse manual drawing 64 95 Extended drawing 96 127 Contraction drawing 128 1...

Страница 11: ...s whether the digital display sequence is selected when the mixed mode of the built in mode is used Note SEL status flag indicates whether the sequence is selected DR indicates the X mirror setting DR...

Страница 12: ...to a recycling centre Ask your local authorities or your dealer about the way to proceed LASER A USAGE EXCLUSIVEMENT PROFESSIONNEL Ce laser est conforme aux normes EN60825 1 2014 il est usage exclusi...

Страница 13: ...de dysfonctionnement arr tez imm diatement l appareil N essayez jamais de r parer l appareil par vous m me Une r paration mal faite peut entra ner des dommages et des dysfonctionnements Contactez un s...

Страница 14: ...d un reset et sont ensuite op rationnels 5 Commandez les appareils avec une console DMX Description Fonction de r glage Chaque pression courte sur le bouton FUNC effectue les actions suivantes INDR DM...

Страница 15: ...naux RESERVE AUX PROFESSIONNELS AVERTIS Order 1 Professional DMX mode is available to the experienced lighting engineers who are professional in DMX Table 1 PATTERN A Note Table 1 CH1 Ch17 pattern A s...

Страница 16: ...Horizontal 4 192 223 Horizontal 5 224 255 Horizontal 6 CH8 Vertical moving 0 63 Manual moving 64 95 vertical 1 96 127 vertical 2 128 159 vertical 3 160 191 vertical 4 192 223 vertical 5 224 255 vertic...

Страница 17: ...l drawing 64 95 Extended drawing 96 127 Contraction drawing 128 159 Both ends are zoomed at the same time 160 191 Head and tail were zooming 192 223 Walking drawing 224 255 Turn over drawing CH16 Auxi...

Страница 18: ...ue exceeds the number of patterns the system uses the largest number CH22 Patterns zooming 0 No zooming 1 31 Zooming 1 32 63 Zooming 2 64 95 Zooming3 96 127 Zooming4 128 159 Zooming 5 160 191 Zooming...

Страница 19: ...Array control 0 63 Normal blanking control 64 127 Patterns without blanking flyback line banking 128 159 Patterns and line without blanking 160 191 Pattern A anchored in an array pattern of pattern B...

Страница 20: ...sur les touches pour entrer l adresse DMX en mode de r glage vous povuez s lectioner la distance de projection lors du r glage de l angle de projection En mode lecture de sc ne appuyez pour ajuster l...

Отзывы: